Digital different. pressure transmitter. Application: level, hydrostatic. Diaphragm seal: flange mounted. Linearity +/-0,1%, turndown 100:1. High static pressure. Safety by function monitoring. Modular transmitter design. :: High reliability Vacuum: Comply with application limits!
Successor
Differential pressure transmitter with one diaphragm seal for level measurement
Read more
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Characteristic
Digital differential pressure transmitter for hydrostatic level measurement with diaphragm seal on process Safety by function monitoring, modular transmitter design
Supply voltage
4...20mA / HART: 11,5...45V DC Ex: 11,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC Ex: 9...24VDC
Long term stability
0,1% of URL/year 0,25% of URL/5 years
Process connection
Low pressure side: 1/4-18NPT RC1/4" High pressure side: Flanges (DIN, ASME, JIS)
Communication
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Certificates / Approvals
ATEX FM CSA TIIS SIL NACE WHG/overspill protection EN10204-3.1
Characteristic / Application
Digital differential pressure transmitter for hydrostatic level measurement with diaphragm seal on process Safety by function monitoring, modular transmitter design
Supply / Communication
4...20mA / HART: 11,5...45V DC Ex: 11,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC Ex: 9...24VDC
Long term stability
0,1% of URL/year 0,25% of URL/5 years
Process pressure / max. overpressure limit
Process connection
Low pressure side: 1/4-18NPT RC1/4" High pressure side: Flanges (DIN, ASME, JIS)
Max. measurement distance
Communication
4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Certificates / Approvals
ATEX FM CSA TIIS SIL NACE WHG/overspill protection EN10204-3.1
Options
digital display SS- or Aluminumhousing
Most downloaded
Technical Information Deltabar S
English version - 09/2005
Deltabar S PMD230, PMD235, FMD230, FMD630, FMD633, Differential pressure
transmitter
EN
DE FR IT PL
More
30/09/2005
01/04/2000
Language:
English
Version:
30/09/2005
File size:
1.6 MB
File name:
TI256PEN.PDF
41 documents
Technical Information Deltabar S
Deltabar S PMD230, PMD235, FMD230, FMD630, FMD633, Differential pressure transmitter
EN
German French Italian Polish
Select other language
30/09/2005
01/04/2000
Language:
English
Version:
30/09/2005
File size:
1.6 MB
File name:
TI256PEN.PDF
Operating Instructions Deltabar S HART/INTENSOR.
Deltabar S with ceramic and silicon sensors overload resistant with funtion monitoring. (Software version 7.1)
EN
German
Select other language
01/05/2003
Language:
English
Version:
01/05/2003
File size:
2.2 MB
File name:
BA174PEN.pdf
Deltabar S FOUNDATION Fieldbus Operating Instructions, Software version
0.3
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75, Differential pressure transmitter
Language:
English
Version:
01/09/2004
File size:
1.7 MB
File name:
BA212PEN.PDF
Operating Instructions Deltabar S PROFIBUS-PA Differential Pressure
Measurement
Deltabar S with ceramic and silicon sensors overload resistant with funtion monitoring.
EN
German French
Select other language
01/08/2002
Language:
English
Version:
01/08/2002
File size:
2.7 MB
File name:
Ba167pen.pdf
Deltabar S FMD230, FMD630, FMD633, PMD230, PMD235
Approval No.: EG 01 011 ATEX II 3 G Protection: EEx nA II T6 4...20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
EN
German French
Select other language
01/03/2002
Language:
English
Version:
01/03/2002
File size:
253.1 KB
File name:
XA151PA3.PDF
Safety Instructions
Deltabar S FMD230, FMD630, FMD633, PMD230, PMD235
FOUNDATION Fieldbus II 1/2 G, II 2 G EEx ia IIC T6...T4 PTB 98 ATEX 2180 (ATEX)
EN
German French
Select other language
01/03/2002
Language:
English
Version:
01/03/2002
File size:
271.1 KB
File name:
XA089PA3.PDF
Safety Instructions
Deltabar S FMD230, FMD630, FMD633, PMD230, PMD235
PROFIBUS PA II 1/2 G, II 2 G EEx ia IIC T6...T4 PTB 98 ATEX 2180 (ATEX)
EN
German French
Select other language
01/03/2002
Language:
English
Version:
01/03/2002
File size:
431.6 KB
File name:
XA003PA3.PDF
Deltabar S FMD630, FMD633, PMD230, PMD235
Approval No.: EG 04 008-a ATEX II 3 D 4...20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
EN
German French
Select other language
01/02/2004
Language:
English
Version:
01/02/2004
File size:
183.1 KB
File name:
XA302PA3.pdf
Safety Instructions
Deltabar S FMD230, FMD630, FMD633, PMD230, PMD235
4...20 mA HART II 1/2 G, II 2 G EEx ia IIC T6...T4 KEMA 97 ATEX 4495 (ATEX)
EN
German French
Select other language
01/03/2002
Language:
English
Version:
01/03/2002
File size:
262 KB
File name:
XA002PA3.PDF
Safety Instructions
Deltabar S FMD630, FMD633, PMD235
II 2 G EEx d IIC T6...T5 PTB 98 ATEX 1060 X (ATEX)
EN
German French
Select other language
01/03/2002
Language:
English
Version:
01/03/2002
File size:
256 KB
File name:
XA005PA3.PDF
Search spare parts by number in drawing
34 spare parts & accessories
34 spare parts
34 accessories
Adapter M26 > Pg13,5, EN AW-6023/6026
Drawing number
Order code
16
919584-0000
Adapter M26 > M20, EN AW-6023/6026
Drawing number
Order code
16
919584-0001
Adapter M26 > NPT1/2, EN AW-6023/6026
Drawing number
Order code
16
919584-0002
Adapter M26 > G1/2, EN AW-6023/6026
Drawing number
Order code
16
919584-0003
Adapter M26 > Pg13.5, 304
Drawing number
Order code
16
919584-0010
Adapter M26 > NPT1/2, 304
Drawing number
Order code
16
919584-0012
Blind plug, M20 h12/6, LD-PE
Drawing number
Order code
14
015797-2000
Blind plug, NPT1/2 h16.5 LD-PE
Drawing number
Order code
14
013990-0000
Blind plug, G1/2A h12/6 HD-PE
Drawing number
Order code
14
016137-0012
Adhesive LOCTITE 638, thread til 1-1/4
Stop angle (15x 23) +screw M5 -SS
Drawing number
Order code
18
52023588
Cover T4 M66, window PC, grey
Drawing number
Order code
20
942856-0200
Cover T4 M66, mineral window, grey
Drawing number
Order code
20
942856-0210
Cover T4 Alu, window, Ex d
Drawing number
Order code
20
942856-1200
Drawing number
Order code
20
942851-0201
Cover T4"Z" Alu, coated, EEx d
Drawing number
Order code
20
942851-1201
Drawing number
Order code
20
52010250
Drawing number
Order code
25
942851-0201
Cover T4"Z" Alu, coated, EEx d
Drawing number
Order code
25
942851-1201
Drawing number
Order code
25
52010249
O-ring 42.52x2.62 NBR 70, 5 pieces
Drawing number
Order code
11
52010140
O-ring 61,6 x 2,62 NBR 70 +PTFE
Drawing number
Order code
21
013982-0000
Electronics Cbar S/Dbar S,Ex,INTENSOR
Drawing number
Order code
30
528400-1214
Electronics Cbar S/Dbar SEx,HART,v7.1
Drawing number
Order code
30
52017521
Electronics Cbar S/Dbar S,PA,3.0, 2.2
Drawing number
Order code
30
52015052
Electronics Cbar S/Dbar S, FF, v1.0a
Drawing number
Order code
30
52010257
Electronic box "C4" PPE+PS-FR
Drawing number
Order code
32
919362-0010
Support ring electron. INTENSOR/HART
Drawing number
Order code
33
919363-0000
Support ring electronics PROFIBUS PA
Drawing number
Order code
33
919363-1000
Adapter ring electron. C/Dbar S,FD FB
Drawing number
Order code
33
52006045
Disc insulating (F4/T4)50.8x1.5,PA FF
Drawing number
Order code
34
942821-0000
Terminal 3pole, RFI-filter
Drawing number
Order code
35
543170-3000
Terminal 3pole, PROFIBUS PA
Drawing number
Order code
35
543170-2100
Digital display VU3000 D=49 cable 4p
Drawing number
Order code
40
942037-0001
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all