Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Body: 316L stainless steel
Window: Proprietary material, optimized for bioprocesses
Surface finish: Ra 15 with Electropolish to ASME BPE SF4 finish
Adhesive: USP Class VI and ISO 10993 compatible
120 or 220 mm
4.73 or 8.67 inch
Autoclave, gamma irradiation
The bio sleeve is a critical consumable part for easy, real-time bioprocess measurements with maximum sterility and efficiency. It connects to a reusable, automatically aligned multi optic which pairs with an Rxn-10 probe. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactor setups.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance
Autoclavable, gamma sterilizable, and compatible with standard cleaning protocols
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
120 mm version is compatible with Endress+Hauser flow assembly CYA680
High-end producten
Technische topkwaliteit
Eenvoud
Eenvoudige producten
Technische topkwaliteit
Eenvoud
Standaardproducten
Technische topkwaliteit
Eenvoud
Gespecialiseerde producten
Technische topkwaliteit
Eenvoud
Variabel
| FLEX selectie | Technische topkwaliteit | Eenvoud |
|---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
System design and specifications for the multi optic calibration
and verification kit
| EN | NL | ||
|
26/06/2023
|
|
|
|
Taal: |
Engels |
|
Versie: |
26/06/2023 |
|
Bestandsgrootte: |
478.7 KB |
|
Bestandsnaam: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for Rxn-10 probe optics: Raman
immersion optics (KIO1), non-contact optics (KNCO1),
bIO-Optics (KLBIO1), bio multi optics (KRBMO), bio sleeves
(KRBSL), and Raman optic system for single use (KRSU1)
| EN | NL | ||
|
09/07/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
Taal: |
Engels |
|
Versie: |
09/07/2026 |
|
Bestandsgrootte: |
504.3 KB |
|
Bestandsnaam: |
TI01635CEN_0426.pdf |
System design and specifications for the Raman Rxn-10 probe
| EN | NL | ||
|
08/09/2025
|
|
|
|
|
13/11/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Taal: |
Engels |
|
Versie: |
08/09/2025 |
|
Bestandsgrootte: |
949 KB |
|
Bestandsnaam: |
TI01629CEN_0525.pdf |
Commissioning, operation, and maintenance details for Rxn-10
probe optics: Raman immersion optics (KIO1), non-contact
optics (KNCO1), bIO-Optics (KLBIO1), bio multi optic
(KRBMO), bio sleeve (KRBSL), and Raman optic system for
single use (KRSU1)
| EN | NL | ||
|
08/06/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Taal: |
Engels |
|
Versie: |
08/06/2026 |
|
Bestandsgrootte: |
2.9 MB |
|
Bestandsnaam: |
BA02171CEN_0426.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
| EN | NL | ||
|
08/09/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Taal: |
Engels |
|
Versie: |
08/09/2025 |
|
Bestandsgrootte: |
1.8 MB |
|
Bestandsnaam: |
BA02160CEN_0525.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
| EN | NL | ||
|
26/06/2023
|
|
|
|
Taal: |
Engels |
|
Versie: |
26/06/2023 |
|
Bestandsgrootte: |
996.4 KB |
|
Bestandsnaam: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Quick start guide for the Raman Rxn-10 probe
| EN | NL | ||
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Taal: |
Engels |
|
Versie: |
02/12/2024 |
|
Bestandsgrootte: |
1.6 MB |
|
Bestandsnaam: |
KA01546CEN_0424.pdf |
Quick start guide for Rxn-10 probe optics: Raman immersion optics
(KIO1), non-contact optics (KNCO1), bIO-Optics (KLBIO1), bio
multi optics (KRBMO), bio sleeves (KRBSL), and
Raman optic system for single use (KRSU1)
| EN | NL | ||
|
08/06/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
Taal: |
Engels |
|
Versie: |
08/06/2026 |
|
Bestandsgrootte: |
1.1 MB |
|
Bestandsnaam: |
KA01551CEN_0426.pdf |
This self-assessment questionnaire helps pharmaceutical and API
manufacturers evaluate their readiness for implementing online
Raman spectroscopy. A simple scoring system identifies potential
infrastructure, integration, and process monitoring challenges, helping
teams assess deployment complexity and prepare for successful
real-time analytical monitoring.
|
Taal: |
Engels |
|
Versie: |
24/08/2026 |
|
Bestandsgrootte: |
111.2 KB |
|
Bestandsnaam: |
PU01649CEN_0126.pdf |
This self-assessment questionnaire helps bioprocessing teams evaluate
analytical costs and delays associated with scaling up from laboratory
development to production. A scoring system helps identify optimization
opportunities and assess the value of real-time monitoring using online
Raman spectroscopy.
|
Taal: |
Engels |
|
Versie: |
24/08/2026 |
|
Bestandsgrootte: |
111.4 KB |
|
Bestandsnaam: |
PU01647CEN_0126.pdf |