TLSC5
South African style temperature assembly

TLSC5
South African style temperature assembly ©Endress+Hauser

Comprehensive and common temperature measurement technology for almost all branches of industry

The thermometer is mainly used in the chemical industry but also finds its use in other branches. The device with head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections and dimensions offer flexible application possibilities.

  • Voordelen

    • Various types of thermocouples: Type J (Fe-CuNi), type K (NiCr-Ni), type N (NiCrSi-NiSi) or type T (Cu-CuNi)

    • Sheath material ANSI 316SS or 310SS, INCONEL600

    • Customized immersion length

    • Electrical connection by means of a ceramic terminal block or head...

  • Toepassingsgebied

    Thermocouple sensor for industrial applications. It consists of a 6 mm diameter stem with either a transmitter mounting plate or a ceramic terminal block for electrical connection. The hot junction can be either "grounded" or "ungrounded" from the...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Thermocouple

  • Characteristic / Application

    S.A. Style

    universal range of application

    usable with or without a thermowell

    spring loaded for use in thermowell

    Options available to construct removable inserts (spare parts)

  • Terminal head

    wide range of heads possible

    possible materials of construction: PVC, aluminium, SS316

    mixed output options possible

  • Thermowell / protection tube

    to use with or without thermowell (can be ordered separately)

  • Insert / probe

    mineral insulated (MI), flexible

  • Max. immersion length on request

    up to 2.000 mm (78,74'')

  • Material protection tube/ thermowell

    1.4401 (316)

    1.4841 (310)

    Alloy 600 (2.4816)

  • Optional coating

    Not defined

  • Process connection

    Union nipple:

    NPT 1/2"

    G1/2"

  • Tip shape

    straight

  • Operating temperature range

    Type J:

    -210 ...760 °C

    (-346 ...1.400 °F)

    Type K:

    -270 ...1.100 °C

    (-454 ...2.012 °F)

    Type N:

    -270 ...1.100 °C

    (-454 ...2.012 °F)

    Type T:

    -270 ...400 °C

    (-454 ...725 °F)

  • Max. process pressure (static)

    at 20 °C: 10 bar (150 psi) without thermowell

  • Accuracy

    class 1 acc. to IEC 60584

  • Response time

    depending on configuration

  • Integration head transmitter

    yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    EN10204 3.1 Material traceability

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (europees)

      2x schroef, 2x veer, 2x springveer, 1x afdichting CDI-connector

  • B
    • Nr B Order code TMT181-

      iTEMP TMT181, koptransmitter PCP

      Temperatuur transmitter, PC- programmeerbaar. Toepassing: RTD, TC, TC, Ohm, mV. 2-draads 4-20mA, galvanische isolatie. Foutreactie: NAMUR NE 43. Montage: kopvorm B, DIN EN50446. UL vermeld.

    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      PROFIBUS PA temperatuur transmitter voor kop- of veldmontage met dubbele sensoringang en advanced diagnostics voor sensorbewaking. Profibus PA Profile 3.02. Galvanische isolatie 2kV. Stroomverbruik: 11 mA. Montage: aansluitkop vorm B, DIN EN50446. Standaard fabrieksinstelling: Kanaal 1: Pt100, 3-draads, oC. kanaal 2: inactief. Meerdere configuraties selecteerbaar.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      FOUNDATION Fieldbus temperatuur transmitter voor kop- of veldmontage met dubbele sensoringang en advanced diagnostics voor sensorbewaking. Galvanische isolatie 2 kV Meetsignaal: RTD, TC, Ohm, mV. Stroomverbruik: 11 mA.

    • Nr B Order code TID10-

      Display voor koptransmitter TID10

      Opsteek display voor koptransmitters. Dot-matrix met weergave gemeten waarde. 12 DIP-switches aan onderzijde. Instellingen: FF: Simulatie, write Lock. PA: Bus adres, write Lock. Geschikt voor: TMT85, TMT84 en TMT82

    • Nr B Order code TMT182-

      iTEMP TMT182, koptransmitter HART

      Temperatuurtransmitter, Protocol HART. Toepassing: RTD, TC, TC, Ohm, mV. 2-draads 4-20mA, SIL2, galvanische isolatie. Foutreactie: NAAM NE 43. Montage: kopvorm B, DIN EN50446. UL vermeld.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-draads temperatuurtransmitter. Dubbele universele sensoringang. Galvanische scheiding 2 kV (input/ output). Toepassing: RTD, TC, Ohm en mV. :: Zeer betrouwbaar door drift detectie en sensor back-up. :: Optioneel ook voor veiligheidskritieke applicaties door middel van SIL 2/3 acc. naar IEC61508

    • Order code FXA195-

      Commubox FXA195 (USB)

      USB HART interface ten behoeve van universele configuratie tools (b.v. FieldCare) De stroomuitgang (4..20mA) is intrinsiek veilig uitgevoerd (SIL2, IEC61508) De interface wordt via de bijgeleverde kabel aan een PC of laptop aangesloten. De interface wordt gevoed via USB

    • Order code READWIN-

      ReadWin2000 configuratie/uitleessoftware

      ReadWin2000 configuratie software

    • Order code TXU10-

      Configuratiekit TXU10

      Set-up software incl. USB- interfacekabel. Dit betreft een product uit het E-direct portfolio waar staffelprijzen aan gekoppeld zijn. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 51001112

      Reservedelenset voor TMT181/187/188/182

      (4 schroeven, 6 veren, 10 veerringen)