T54
Explosion proof TC thermometer, US style

©Endress+Hauser

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.

Dit product is niet verkrijgbaar in deze markt.

  • Voordelen

    • FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety

    • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications

    • Remove and install...

  • Toepassingsgebied

    The sensor assembly can be used in process industries such as:

    • Chemicals

    • Petrochemical

    • Refineries

    • Offshore Platforms

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Thermocouple

  • Characteristic / Application

    Explosion Proof US style

    modular temperature assembly

    for heavy duty applications

    flanged process connection

    with extension

    incl. Thermowell

  • Terminal head

    TMT162 - aluminium - fieldhousing w. or w/o. display

    TMT162 - SS - fieldhousing w. or w/o. display

    TMT142 - aluminium - fieldhousing w. or w/o. display

    TA30H - aluminum - w. or w/o. display

  • Thermowell / protection tube

    bar stock (drilled)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    7/8'' (22,23 mm)

    17/16'' (26,99 mm)

  • Max. immersion length on request

    up to 22.5" (571 mm)

    others on request

  • Material protection tube/ thermowell

    316/316L

    auf Anfrage

  • Optional coating

    available on request

  • Process connection

    flange:

    ASME 1" 150 RF (B16.5)

    ASME 1" 300 RF (B16.5)

    ASME 1" 600 RF (B16.5)

    ASME 1,5" 150 RF (B16.5)

    ASME 1,5" 300 RF (B16.5)

    ASME 1,5" 600 RF (B16.5)

    ASME 2" 150 RF (B16.5)

    ASME 2" 300 RF (B16.5)

    ASME 2" 600 RF (B16.5)

  • Tip shape

    straight

    tapered

  • Surface roughness Ra

    32 μin (0.80 μm)

  • Operating temperature range

    Type T:

    -270 °C ...370 °C

    (-454 °F ...698 °F)

    Type J:

    -210 °C ...720 °C

    (-346 °F ...1.328 °F)

    Type E:

    -270 °C ...820 °C

    (-454 °F ...1.508 °F)

    Type K:

    -270 °C ... 1.150 °C

    (-454 °F ...2.102 °F)

    Type N:

    -270 °C ... 1.150 °C

    (-454 °F ...2.102 °F)

  • Max. process pressure (static)

    at 20°C : 500bar (7.252 psi)

    depends on configuration

  • Accuracy

    Standard acc. to ASTM E-230

    Special acc. to ASTM E-230

  • Response time

    depending on configuration

    63% rt = 15 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    FM XP

    CSA XP

    FM/CSA XP

    CSA GP

  • Certification

    SIL (transmitter only)

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • F
  • A
    • Nr A Order code TU121-

      TC-Insert TU121, Gen.Purp. U.S.Style

      Reserveonderdeel. Thermokoppel met veer geladen. Thermokoppel voldoen aan EMF tabellen van ASTM E-230 en IEC60584. Kleurcodes per ASTM E-230.

  • E
    • Nr E Order code TU54-

      Thermowell TU54, Flanged U.S.Style

      Bar voorraad Thermowell, CRN nummer. De flens wordt gelast.

  • F
    • Nr F Order code TA30H-

      Aansluitkop TA30H

      Aansluitkop voor aansluitblok of koptransmitter + optioneel display. Deksel: geschroefd, optioneel met venster. Materiaal: aluminium Coating: polyester poeder-coating. Kleur: huis blauw, deksel grijs. Omgevingstemperatuur.: -50...150 oC. Beschermingsklasse: IP66/68, NEMA 4X.

    • Order code TMT142E-

      Elektronica TMT142E

    • Order code TMT162E-

      TMT162E elektronika

    • Order code TMT181-

      iTEMP TMT181, koptransmitter PCP

      Temperatuur transmitter, PC- programmeerbaar. Toepassing: RTD, TC, TC, Ohm, mV. 2-draads 4-20mA, galvanische isolatie. Foutreactie: NAMUR NE 43. Montage: kopvorm B, DIN EN50446. UL vermeld.

    • Order code TMT182-

      iTEMP TMT182, koptransmitter HART

      Temperatuurtransmitter, Protocol HART. Toepassing: RTD, TC, Ohm, mV. 2-draads 4-20mA, galvanische isolatie. Foutreactie: NAMUR NE 43. Montage: kop vorm B, DIN EN50446. UL vermeld. Temperatuurtransmitter, Protocol HART. Toepassing: RTD, TC, Ohm, mV. 2-draads 4-20mA, galvanische isolatie. Foutreactie: NAMUR NE 43. Montage: kop vorm B, DIN EN50446. UL vermeld.

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-draads temperatuurtransmitter. Dubbele universele sensoringang. Galvanische scheiding 2 kV (input/ output). Toepassing: RTD, TC, Ohm en mV. :: Zeer betrouwbaar door drift detectie en sensor back-up. :: Optioneel ook voor veiligheidskritieke applicaties door middel van SIL 2/3 acc. naar IEC61508

    • Order code TMT84-

      iTEMP TMT84, Transmitter PA

      PROFIBUS PA temperatuur transmitter voor kop- of veldmontage met dubbele sensoringang en advanced diagnostics voor sensorbewaking. Profibus PA Profile 3.02. Galvanische isolatie 2kV. Stroomverbruik: 11 mA. Montage: aansluitkop vorm B, DIN EN50446. Standaard fabrieksinstelling: Kanaal 1: Pt100, 3-draads, oC. kanaal 2: inactief. Meerdere configuraties selecteerbaar.

    • Order code TMT85-

      iTEMP TMT85, Transmitter FF

      FOUNDATION Fieldbus temperatuur transmitter voor kop- of veldmontage met dubbele sensoringang en advanced diagnostics voor sensorbewaking. Galvanische isolatie 2 kV Meetsignaal: RTD, TC, Ohm, mV. Stroomverbruik: 11 mA.

    • Order code READWIN-

      ReadWin2000 configuratie/uitleessoftware

      ReadWin2000 configuratie software

    • Order code TID10-

      Display voor koptransmitter TID10

      Opsteek display voor koptransmitters. Dot-matrix met weergave gemeten waarde. 12 DIP-switches aan onderzijde. Instellingen: FF: Simulatie, write Lock. PA: Bus adres, write Lock. Geschikt voor: TMT85, TMT84 en TMT82

    • Order code TXU10-

      Configuratiekit TXU10

      Set-up software incl. USB- interfacekabel. Dit betreft een product uit het E-direct portfolio waar staffelprijzen aan gekoppeld zijn. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code FXA195-

      Commubox FXA195 (USB)

      USB HART interface ten behoeve van universele configuratie tools (b.v. FieldCare) De stroomuitgang (4..20mA) is intrinsiek veilig uitgevoerd (SIL2, IEC61508) De interface wordt via de bijgeleverde kabel aan een PC of laptop aangesloten. De interface wordt gevoed via USB