Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Hydrostatic

  • Characteristic / Application

    Cable probe for hydrostatic level measurement,
    with ceramic cell
    Diameter = 22mm:
    General applications, Drinking water
    Diameter = 42mm:
    Wastewater applications
    Diameter = 29mm:
    Salt water applications

  • Specialities

    version w/o metal parts in contact to process

  • Supply / Communication

    10...30V DC

  • Accuracy

    0.2%

  • Long term stability

    0.1% of URL/year

  • Ambient temperature

    -10°C...70°C

    (14°F...158°F)

    Diameter 29mm (1.14"):

    0°C...50°C

    (32°F...122°F)

  • Process temperature

    -10°C...70°C
    (14°F...158°F)
    Diameter 29mm (1.14"): 0°C...50°C
    (32°F...122°F)

  • Process pressure absolute / max. overpressure limit

    40bar (600psi)

  • Pressure measuring range

    100mbar...20bar
    (1.5psi...300psi)

  • Main wetted parts

    Diameter 22mm and 42mm:
    Seal, 316L, Ceramic
    Diameter 29mm:
    Seal, PPS, Polyolefin, Ceramic
    Extension cable: PE, PUR, FEP

  • Process connection

    Suspension clamp

    Cable mounting screws

  • Max. measurement distance

    200m H2O
    (656 ft H2O)

  • Communication

    4...20 mA

  • Certificates / Approvals

    ATEX, FM, CSA

  • Marine approval

    GL/ ABS

  • Drinking water approvals

    KTW/ NSF/ ACS

  • Options

    Integrated temperature sensor Pt100, 4-wire

    customer specific adjustment

    customer specific cable marking

  • Successor

    FMX21 with analog output

  • Application limits

    Measuring cell: ceramics

  • Meetprincipe

    Hydrostatic pressure

  • Characteristic

    Cable probe for hydrostatic level measurement,
    with ceramic cell
    Diameter = 22mm:
    General applications, Drinking water
    Diameter = 42mm:
    Wastewater applications
    Diameter = 29mm:
    Salt water applications

  • Supply voltage

    10...30V DC

  • Reference Accuracy

    0.2%

  • Long term stability

    0.1% of URL/year

  • Process temperature

    -10°C...70°C
    (14°F...158°F)
    Diameter 29mm (1.14"): 0°C...50°C
    (32°F...122°F)

  • Ambient temperature

    -10°C...70°C

    (14°F...158°F)

    Diameter 29mm (1.14"):

    0°C...50°C

    (32°F...122°F)

  • Measuring cell

    40bar (600psi)

  • Communication

    4...20 mA

  • Certificates / Approvals

    ATEX, FM, CSA

  • Marine approvals

    GL/ ABS

  • Drinking water approvals

    NSF/ KTW/ ACS

  • Successor

    FMX21 with analog output

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
    • Order code 52005578

      FMX167, drukvereffeningssetje

      Consists of: 10x teflon filter. 5x filter socket. Usage: FMX21, FMX167.

    • Order code 52008999

      FMX167 membraam beschermkap (5 stuks)

      Caps to protect the membrane. Usage: FMX21, FMX167, 22mm.

    • Order code 917755-0000

      Protection cover, PFA

      Usage: DB4x/DB5x, FMX165, FMX167/FMX21 42mm.

    • Order code 52006152

      Aansluitdoos voor FMX167 (IP66/IP67)

      Behuizing incl. schroefklemmen voor sonde aansluiting (zonder Pt100), incl. compensatie filter. Gebruik: FMX21, FMX167.

    • Order code 52006151

      Montagebeugel FMX21, FMX167, 316L

      Gebruik: bevestiging kabel (7.5-10.5mm).

    • Order code 52008264

      Kabelmontageschroef G1½A, SS304

      Gebruik: montage FMX21, FMX167.

    • Order code 52009311

      Inschroefdeel NPT 1 1/2", SS304

      Gebruik: montage FMX21, FMX167.

    • Order code 52006153

      Extra gewicht voor FMX167, 316L

      Verhoging van de sensor-gewicht bij 300g. Verschillende gewichten per sonde mogelijk. Diameter 22mm/0.87in + 29mm/1.15in.

    • Order code 52008938

      Binding posts terminal box FMX21, FMX167

      Viervoudige schroefklemmen voor Pt100 bekabeling in het huis 52.006.152.

    • Order code 52011868

      Test adapter FMX21, FMX167

      Druk toelating + functionele test Diameter 22mm/0.87in + 29mm/1.15in.

  • Opvolger