Proline Promass Q 500
Coriolis flowmeter

Coriolis flowmeter - Proline Promass Q 500 ©Endress+Hauser
German Innovation Award 2018 GOLD

The German Innovation Award recognizes industry-wide products that set themselves apart from currently-available solutions through their added value.

The Coriolis Flow Measuring Principle

Proline Promass Q - The flow specialist for the exact measurement of liquids with entrained gas

The innovative specialist for challenging applications, as remote version with up to 4 I/Os

Promass Q 500 provides the highest measurement accuracy for mass flow, volume flow and density. Being the preferred choice for custody transfer applications, it has also been optimized for liquid applications where entrained gas is known to be present. With its innovative remote transmitter Promass Q 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.

  • Voordelen

    • Secured measuring quality – unmatched accuracy of mass flow, volume flow and density

    • Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology)

    • Fewer process measuring points – multivariable measurement (flow, density,...

  • Toepassingsgebied

    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • Highest measurement performance for density and challenging applications

    Device properties

    • Mass flow: measured error ±0.05 % (PremiumCal)

    • Density:...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Coriolis

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow and density. Highest measurement performance for custody transfer, density and tough process conditions.

  • Sensor features

    Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 25 to 100 (1 to 4")

  • Wetted materials

    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.35 %
    Density (liquid): ±0.2 kg/m³

  • Measuring range

    0 to 400 000 kg/h (0 to 14 697 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    Standard: –50 to +205°C (–58 to +401 °F)
    Option: –196 to +150 °C (–321 to +302 °F)

  • Ambient temperature range

    Standard: - 4 to +60 °C (–4 to +140 °F)
    Option:–60 to +60 °C (–76 to +140 °F)

  • Sensor housing material

    1.4404 (316L), highest corrosion resistance

    Sensor connection housing (standard): AlSi10Mg, coated

    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)
    MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids)
    OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids)
    NTEP (Liquids other than water, Cryogenic liquids)

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

  • Hygienic approvals and certificates

    3-A, EHEDG, cGMP

  • Meetprincipe

    Coriolis

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow and density. Highest measurement performance for custody transfer, density and tough process conditions.

  • Sensor features

    Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 25 to 100 (1 to 4")

  • Wetted materials

    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.35 %
    Density (liquid): ±0.2 kg/m³

  • Measuring range

    0 to 400 000 kg/h (0 to 14 697 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    Standard: –50 to +205°C (–58 to +401 °F)
    Option: –196 to +150 °C (–321 to +302 °F)

  • Ambient temperature range

    Standard: - 40 to +60 °C (–40 to +140 °F)
    Option:–60 to +60 °C (–76 to +140 °F)

  • Sensor housing material

    1.4404 (316L), highest corrosion resistance

    Sensor connection housing (standard): AlSi10Mg, coated

    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)
    MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids)
    OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids)
    NTEP (Liquids other than water, Cryogenic liquids)

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

  • Hygienic approvals and certificates

    3-A, EHEDG, cGMP

  • Meetprincipe

    Coriolis

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow and density. Highest measurement performance for custody transfer, density and tough process conditions.

  • Sensor features

    Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 25 to 100 (1 to 4")

  • Wetted materials

    Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
    Volume flow (liquid): ±0.10 %
    Mass flow (gas): ±0.35 %
    Density (liquid): ±0.2 kg/m³

  • Measuring range

    0 to 400 000 kg/h (0 to 14 697 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    Standard: –50 to +205°C (–58 to +401 °F)
    Option: –196 to +150 °C (–321 to +302 °F)

  • Ambient temperature range

    Standard: - 4 to +60 °C (–4 to +140 °F)
    Option:–60 to +60 °C (–76 to +140 °F)

  • Sensor housing material

    1.4404 (316L), highest corrosion resistance
    Sensor connection housing (standard): AlSi10Mg, coated
    Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)
    MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids)
    OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids)
    NTEP (Liquids other than water, Cryogenic liquids)

  • Pressure approvals and certificates

    PED, CRN, AD 2000

  • Material certificates

    3.1 material
    NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

  • Hygienic approvals and certificates

    3-A, EHEDG, cGMP

  • Meetprincipe

    Coriolis

  • Product headline

    Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow and density. Highest measurement performance for custody transfer, density and tough process conditions.

  • Sensor features

    Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³.

  • Hygienic approvals and certificates

    cGMP

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 31
    • Nr 31 Order code 71323007

      Kit power supply, 100-230VAC, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing, elektronisch compartiment.

    • Nr 31 Order code 71323008

      Kit power supply, 24VDC, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing, elektronisch compartiment.

    • Nr 31 Order code 71323009

      Kit pow.supply,100-230VAC/24VDC, Non-haz

      Gebruik: Promag/Promass 300/500 digitaal. Niet gevaarlijk, Zone 2, transmitterbehuizing, elektronisch compartiment.

  • 47
    • Nr 47 Order code 71323012

      Kit main elec.extend.,Promass500 dig.,Ex

      Gebruik: transmitterbehuizing, elektronisch compartiment.

    • Nr 47 Order code 71323013

      Kit main elec.extender,500 dig., Non-haz

      Gebruik: Transmitterbehuizing, elektronisch compartiment.

  • 36
  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, Promass 100

      Gebruik: Promag / Promass 100/300/500, 500 digitaal, Prosonic Flow E 100, Promag 400 (C). (C) = opwekkingsindex C.

  • 33
  • 37
    • Nr 37 Order code 71323010

      Kit module cartridge, 300/500, Ex

      Gebruik: Transmitterbehuizing, elektronisch compartiment. Bestaat uit: module cartridge incl. interconnectie board.

  • 34
  • 46
  • 45
    • Nr 45 Order code 71323075

      Kit conn.terminal option A, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie A= HART, Profibus PA, FOUNDATION Fieldbus. Bestaat uit: 2x aansluiting 2-Pol., 1x aansluiting 4-Pol.

  • 35
  • 45
    • Nr 45 Order code 71323076

      Kit conn.terminal option B, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: 2 x aansluiting 2-Pol.

  • 50
  • 45
    • Nr 45 Order code 71327819

      Kit conn.terminal option C, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie C= PROFIBUS-DP, Modbus RS485. Bestaat uit: 2x aansluiting 2-Pol., 1x aansluiting 4-Pol.

    • Nr 45 Order code 71323077

      Kit terminal option A, 500 dig., Non-haz

      Gebruik: transmitterbehuizing Alu/polycarbonaat, aansluitruimte. Optie A= HART, Profibus PA, FOUNDATION Fieldbus. Bestaat uit: 1x aansluiting 2-Pol., 1x aansluiting 3-Pol., 1x aansluiting 4-Pol., 1x aansluitklem 6-Pol.

    • Nr 45 Order code 71323078

      Kit terminal option B, 500 dig., Non-haz

      Gebruik: transmitterbehuizing Alu/polycarbonaat, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: 1x aansluiting 3-Pol., 1x aansluiting 4-Pol., 1x aansluitklem 6-Pol.

    • Nr 45 Order code 71327820

      Kit terminal option C, 500 dig., Non-haz

      Gebruik: transmitterbehuizing Alu/polycarbonaat, aansluitruimte. Optie C = PROFIBUS-DP, Modbus RS485. Bestaat uit: 1x aansluiting 2-Pol., 1x aansluiting 3-Pol., 1x aansluiting 4-Pol., 1x aansluitklem 6-Pol.

  • 44
    • Nr 44 Order code 71323268

      Kit connection board, Promass 500, Ex

      Gebruik: Sensoraansluiting behuizing. Bestaat uit: aansluiting board, O-Ring 26,00x1,50 HNBR.

    • Nr 44 Order code 71323269

      Kit connec.board, Promass 500, Ex, -50oC

      Gebruik: Sensoraansluiting behuizing. Bestaat uit: aansluiting board, O-Ring 26,00x1,50 FVMQ, -50°C/-58°F.

    • Nr 44 Order code 71323269

      Kit connec.board, Promass 500, Ex, -50oC

      Gebruik: Sensoraansluiting behuizing. Bestaat uit: aansluiting board, O-Ring 26,00x1,50 FVMQ, -50°C/-58°F.

  • 20
    • Nr 20 Order code 71323016

      Kit cover, sight glass, Alu,Non-haz/Exde

      Gebruik: Promag/Promass 300, transmitterbehuizing Alu, Niet gevaarlijk. Promag/Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-Ring 110.7x3.53 HNBR.

    • Nr 20 Order code 71323017

      Kit cover,glass, Alu, -50oC,Non-haz/Exde

      Gebruik: Promass 300, transmitterbehuizing Alu, niet- gevaarlijk. Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 20 Order code 71323017

      Kit cover,glass, Alu, -50oC,Non-haz/Exde

      Gebruik: Promass 300, transmitterbehuizing Alu, niet- gevaarlijk. Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 20 Order code 71323020

      Kit cover, sight glass, Alu, Exd

      Gebruik: Promag /Promass 300/500, Transmitter behuizing Alu, Ex. Bestaat uit: Cover Alu, zichtglas, O-Ring 110,7x3,53 HNBR.

    • Nr 20 Order code 71323021

      Kit cover, sight glass, Alu, -50oC, Exd

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 20 Order code 71323021

      Kit cover, sight glass, Alu, -50oC, Exd

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 20 Order code 71323024

      Kit cover, sight glass, cast, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, kijkglas, O-Ring 110.7x3.53 HNBR.

    • Nr 20 Order code 71323025

      Kit cover, sight glass, cast, -50oC, Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 20 Order code 71323025

      Kit cover, sight glass, cast, -50oC, Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

  • 70
    • Nr 70 Order code 71323026

      Kit cover gasket, sight glass/blind

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu/cast. Bestaat uit: 10x O-Ring 110.7x3.53 HNBR.

    • Nr 70 Order code 71323027

      Kit cover gasket,sight glass/blind,-50oC

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu/cast, Bestaat uit: O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 70 Order code 71323027

      Kit cover gasket,sight glass/blind,-50oC

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu/cast, Bestaat uit: O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

  • 22
    • Nr 22 Order code 71323032

      Kit cover, electronic compart., Alu, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, O-ring 120,2 x 3,53 HNBR.

    • Nr 22 Order code 71323033

      Kit cover, electr.compart., Alu,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 22 Order code 71323033

      Kit cover, electr.compart., Alu,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 22 Order code 71323034

      Kit cover, electronic compart., cast, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 HNBR.

    • Nr 22 Order code 71323035

      Kit cover, electr.compart.,cast,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 22 Order code 71323035

      Kit cover, electr.compart.,cast,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing cast, Ex. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

  • 74
    • Nr 74 Order code 71323036

      Kit cover gasket, electronic compart.,Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu/cast, Ex. Bestaat uit: 10x O-ring 120,2 x 3,53 HNBR.

    • Nr 74 Order code 71323037

      Kit cover gasket,elect.compart.,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu/cast, Ex. Bestaat uit: O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 74 Order code 71323037

      Kit cover gasket,elect.compart.,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu/cast, Ex. Bestaat uit: O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

  • 23
    • Nr 23 Order code 71323038

      Kit cover, wall mount, Alu, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu, Ex, aansluitruimte. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 HNBR.

    • Nr 23 Order code 71323039

      Kit cover, wall mount, Alu, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount zender Alu, Ex, aansluitruimte. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 23 Order code 71323039

      Kit cover, wall mount, Alu, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount zender Alu, Ex, aansluitruimte. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 23 Order code 71323040

      Kit cover, wall mount, cast, Ex

      Gebruik: Promag/Promass 500, wall mount zender cast, Ex, aansluitruimte. Bestaat uit: deksel gegoten, O-ring 88,50 x 3,53 HNBR.

    • Nr 23 Order code 71323041

      Kit cover, wall mount, cast, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount zender cast, Ex, aansluitruimte. Bestaat uit: deksel gegoten, O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 23 Order code 71323041

      Kit cover, wall mount, cast, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount zender cast, Ex, aansluitruimte. Bestaat uit: deksel gegoten, O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

  • 75
    • Nr 75 Order code 71323042

      Kit cover gasket, wall mount, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, aansluitruimte. Bestaat uit: 10x O-ring 88,50 x 3,53 HNBR.

    • Nr 75 Order code 71323043

      Kit cover gasket, wall mount, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, aansluitruimte. Bestaat uit: O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 75 Order code 71323043

      Kit cover gasket, wall mount, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, aansluitruimte. Bestaat uit: O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

  • 20
    • Nr 20 Order code 71384170

      Kit cover, alu,Promag 400(C),500 digital

      Gebruik: Promag 400(C)= generatie-index C, Promag / Promass 500 digitaal, zenderbehuizing Alu. Bestaat uit: dekking Alu compleet inbegrepen O-ring 196,44x3,53 VMQ, standaard en -50°C/-58°F, draad met schroefslot 1,5x150

    • Nr 20 Order code 71408508

      Kit cover, polycarb., 500 digital

      Gebruik: Promag/Promass 500 digitaal, polycarbonaat behuizing van de zender. Bestaat uit: Bedek polycarbonaat compleet, O-ring 196,44x3,53 VMQ, standaard en -50°C/-58°F, draad met schroefslot 1,5x150.

  • 70
    • Nr 70 Order code 71278078

      Kit 10 cover gasket, alu, 400(C)

      Gebruik: Promag 400(C)= generatie index C, Promag/Promass 500 digitale, transmitterbehuizing Alu, Ex. Bestaat uit: 10x O-Ring 196,44x3,53 VMQ, verzuim en -50°C/-58°F.

    • Nr 70 Order code 71278077

      Kit 10 afdichtingsring, polycarbonaat

      Gebruik: Promag 400(C), 500 digitaal met polycarbonaat behuizing. (C)= generatie-index C. Bestaat uit: 10x O-Ring 196,44x3,53 VMQ.

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Gebruik: Promag 400(C)= generatie index C, Promag 500, Promass/Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 HNBR.

    • Nr 24 Order code 71323050

      Kit cover, remote, Alu, -50oC

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 FVMQ, -50°C/-58°F.

    • Nr 24 Order code 71323050

      Kit cover, remote, Alu, -50oC

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 FVMQ, -50°C/-58°F.

  • 73
    • Nr 73 Order code 71323051

      Kit housing gaskets, remote, Alu

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 HNBR voor dekking, pakking EPDM voor huisvesting/sensor.

    • Nr 73 Order code 71323052

      Kit housing gaskets, remote, Alu, -50°C

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 FVMQ voor dekking, -50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

    • Nr 73 Order code 71323052

      Kit housing gaskets, remote, Alu, -50°C

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 FVMQ voor dekking, -50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

  • 24
    • Nr 24 Order code 71323053

      Kit cover, remote, stainless 1.4301

      Gebruik: Promass 500, Promass/Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking EPDM voor dekking.

    • Nr 24 Order code 71323054

      Kit cover, remote,stainless 1.4301,-50oC

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking FVMQ voor dekking, -50°C/-58°F.

    • Nr 24 Order code 71323054

      Kit cover, remote,stainless 1.4301,-50oC

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking FVMQ voor dekking, -50°C/-58°F.

  • 73
    • Nr 73 Order code 71323057

      Kit housing gaskets, remote, stainless

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: pakking EPDM voor dekking, pakking EPDM voor huisvesting/sensor.

    • Nr 73 Order code 71323058

      Kit hous.gaskets, remote,stainless,-50oC

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: pakking FVMQ voor dekking,-50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

    • Nr 73 Order code 71323058

      Kit hous.gaskets, remote,stainless,-50oC

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: pakking FVMQ voor dekking,-50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

  • 24
    • Nr 24 Order code 71185793

      Kit cover,ultra compact,stainless 1.4301

      Gebruik: Promag/Promass 100, Promag/Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking EPDM voor dekking.

    • Nr 24 Order code 71323060

      Kit cover, ultra compact, 1.4301, -50oC

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking FVMQ voor dekking, -50°C/-58°F.

    • Nr 24 Order code 71323060

      Kit cover, ultra compact, 1.4301, -50oC

      Gebruik: Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: bestrijken roestvrij 1.4301, pakking FVMQ voor dekking, -50°C/-58°F.

  • 73
    • Nr 73 Order code 71185799

      Kit hous. gasket,ultra compact,stainless

      Gebruik: Promass 100, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: pakking EPDM voor dekking, pakking EPDM voor huisvesting/sensor.

    • Nr 73 Order code 71323062

      Kit housing gasket, ultra compact, -50oC

      Gebruik: Promass 500 digitale, sensor aansluiting roestvrijstalen behuizing. Bestaat uit: Pakking FVMQ voor dekking, -50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

    • Nr 73 Order code 71323062

      Kit housing gasket, ultra compact, -50oC

      Gebruik: Promass 500 digitale, sensor aansluiting roestvrijstalen behuizing. Bestaat uit: Pakking FVMQ voor dekking, -50°C/-58°F, pakking FVMQ voor huisvesting/sensor, -50°C/-58°F.

  • 24
    • Nr 24 Order code 71323063

      Kit cover, remote, cast, Ex

      Gebruik: Promag/Promass 500, Promass/Promass 500 digitale, sensor connector behuizing. Bestaat uit: deksel gegoten, O-Ring 120,2x3,53 HNBR.

    • Nr 24 Order code 71323064

      Kit cover, remote, cast, -50oC, Ex

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 FVMQ,-50°C/-58°F

    • Nr 24 Order code 71323064

      Kit cover, remote, cast, -50oC, Ex

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: deksel gegoten, O-ring 120,2 x 3,53 FVMQ,-50°C/-58°F

  • 73
    • Nr 73 Order code 71323065

      Kit housing gaskets, remote, cast, Ex

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 120,2x3,53 HNBR voor dekking, O-ring 88,50 x 3,53 HNBR voor huisvesting/sensor

    • Nr 73 Order code 71323066

      Kit housing gaskets,remote,cast,-50oC,Ex

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 120,2x3,53 FVMQ voor dekking, -50°C/-58 VAn, O-Ring 88,50x3,53 FVMQ voor house./sensor, -50°C/-58°F.

    • Nr 73 Order code 71323066

      Kit housing gaskets,remote,cast,-50oC,Ex

      Gebruik: Promass 500, Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: O-Ring 120,2x3,53 FVMQ voor dekking, -50°C/-58 VAn, O-Ring 88,50x3,53 FVMQ voor house./sensor, -50°C/-58°F.

  • 71
    • Nr 71 Order code 71323071

      Kit interface gaskets, Promass 300/500

      Gebruik: transmitter behuizing/sensor of transmitter behuizing/muurbevestiging. Bestaat uit: 5x O-ring 88,50 x 3,53 HNBR voor interface.

    • Nr 71 Order code 71323072

      Kit interf.gaskets,Promass 300/500,-50°C

      Gebruik: transmitter behuizing/sensor of transmitter behuizing/muurbevestiging. Bestaat uit: O-ring 88,50 x 3,53 FVMQ voor -interface, -50°C /-58°F.

    • Nr 71 Order code 71323072

      Kit interf.gaskets,Promass 300/500,-50°C

      Gebruik: transmitter behuizing/sensor of transmitter behuizing/muurbevestiging. Bestaat uit: O-ring 88,50 x 3,53 FVMQ voor -interface, -50°C /-58°F.

  • 11
    • Nr 11 Order code 71323081

      Kit protective cover option A,300/500,Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie A= HART, Profibus PA, Profibus DP, Modbus RS485, FOUNDATION Fieldbus. Bestaat uit: Aansluitruimte beschermhoes, vertoning vervoerder, 2x schroef M4x10.

    • Nr 11 Order code 71323082

      Kit protective cover option B,300/500,Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: Aansluitruimte beschermhoes, vertoning vervoerder, 2x schroef M4x10.

  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Gebruik: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensorhuis: Promag 400 (C), (C)= opwekkingsindex C, Promag / Promass 500, Promag / Promass 500 digitaal. Bestaat uit: afdekklem, schroef M4x16.

  • 82
    • Nr 82 Order code 71228792

      Kit display protection, Promag 400(C)

      Gebruik: Promag 400(C) = generatie index C, Promag/Promass 500 digitale, transmitterbehuizing. Bestaat uit: beeldscherm bescherming 1.4301, installatiemateriaal.

  • 87
    • Nr 87 Order code 71343504

      Kit weather protection cover,500 digital

      Gebruik: Promag/Promass 500 digital, transmitterbehuizing. Bestaat uit: weer beschermingskap 4404.

    • Nr 87 Order code 71343505

      Kit weather protection cover, 300/500

      Gebruik: Promag/Promass 300/500, transmitterbehuizing. Bestaat uit: weer bescherminskap 4404, installatiemateriaal.