Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
532 nm
150-3425 cm-1 (532 nm)
The Raman Rxn5 process analyzer is an industry-leading, turn-key, laser-based analyzer powered by Kaiser Raman technology. It provides quantitative chemical composition measurements using Raman spectroscopy. The design of the Raman Rxn5 incorporates customer requirements for serviceability and hazard-area certification, provides a compact footprint, and minimizes utilities consumption. The high optical efficiency of the analyzer makes it ideal for typical gas-phase sample measurements.
Process measurement points:
Steam methane reformers
Gasifiers (coal, petcoke, waste, biomass)
Shift converters
Hydrotreaters
Hydrocrackers
CO2 removal
Finished product synthesis loops
Typical industries:
Hydrogen production/purity, HyCO, Hydrogen recycle,
Methanol production
Ammonia production
Gas turbine fuel feed
Synthetic natural gas/IGCC power plants
Non-destructive analysis of gases, including homonuclear diatomics (H2, N2, O2)
Compact, smaller than most wall-mount gas chromatographs (GCs)
Can replace up to four traditional analyzers with a single base unit and four probes
Rugged with minimal utility requirements, no sample transport, and no consumables (columns, valves, gases, pumps)
Minimal analyzer technician time with maximum technician safety (no toxic gases are transported to the analyzer)
Measures four streams simultaneously for faster multi-channel results
-20 to +50 °C operating environment
High-end producten
Technische topkwaliteit
Eenvoud
Eenvoudige producten
Technische topkwaliteit
Eenvoud
Standaardproducten
Technische topkwaliteit
Eenvoud
Gespecialiseerde producten
Technische topkwaliteit
Eenvoud
Variabel
| FLEX selectie | Technische topkwaliteit | Eenvoud |
|---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
System design and specifications for the Raman Rxn5 analyzer -
powered by Kaiser Raman technology
| EN | NL | ||
|
11/11/2025
|
|
|
|
|
21/10/2025
|
|
|
|
|
27/02/2025
|
|
|
|
|
21/11/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Taal: |
Engels |
|
Versie: |
11/11/2025 |
|
Bestandsgrootte: |
3 MB |
|
Bestandsnaam: |
TI01646CEN_0525.pdf |
Commissioning, operation, and maintenance details
for Raman RunTime v6.6 software
| EN | NL | ||
|
27/03/2025
|
|
|
|
|
16/11/2023
|
|
|
|
|
30/06/2022
|
|
|
|
|
31/12/2020
|
|
|
|
Taal: |
Engels |
|
Versie: |
27/03/2025 |
|
Bestandsgrootte: |
6.8 MB |
|
Bestandsnaam: |
BA02180CEN_0525.pdf |
Commissioning, operation, and maintenance details for the
Raman Rxn5 analyzer - powered by Kaiser Raman technology
| EN | NL | ||
|
29/10/2025
|
|
|
|
|
17/03/2025
|
|
|
|
|
16/01/2025
|
|
|
|
|
21/11/2023
|
|
|
|
|
01/08/2023
|
|
|
|
Taal: |
Engels |
|
Versie: |
29/10/2025 |
|
Bestandsgrootte: |
4.6 MB |
|
Bestandsnaam: |
BA02179CEN_0625.pdf |
Quick start guide for the Raman Rxn5 analyzer -
powered by Kaiser Raman technology
| EN | NL | ||
|
13/03/2025
|
|
|
|
|
16/01/2025
|
|
|
|
|
21/11/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Taal: |
Engels |
|
Versie: |
13/03/2025 |
|
Bestandsgrootte: |
2.1 MB |
|
Bestandsnaam: |
KA01554CEN_0425.pdf |
Instructions for use of the LNG analyzer performance verification kit
| EN | NL | ||
|
30/03/2023
|
|
|
|
Taal: |
Engels |
|
Versie: |
30/03/2023 |
|
Bestandsgrootte: |
442.7 KB |
|
Bestandsnaam: |
EA01470CEN_0123.pdf |
Hazardous area certifications and installation instructions
for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
| EN | NL | ||
|
27/02/2025
|
|
|
|
|
13/01/2025
|
|
|
|
|
07/12/2023
|
|
|
|
Taal: |
Engels |
|
Versie: |
27/02/2025 |
|
Bestandsgrootte: |
1.7 MB |
|
Bestandsnaam: |
XA02746CEN_0425.pdf |
この論文では、Endress+Hauserのラマン分光計システムが、水素液
化プロセスにおけるパラ水素変換を高精度に測定できる性能を有す
ることを、実験結果により検証しています。
|
Taal: |
Japans |
|
Versie: |
06/03/2026 |
|
Bestandsgrootte: |
1.1 MB |
|
Bestandsnaam: |
PU01623CJA_0126_Raman_parahydrogen_measurement.pdf |
An overview brochure about our Raman Rxn5 analyzer (including
the Raman Rxn-30 probe, the Rxn-40 probe,), a Raman spectroscopy
analyzer system for gas phase measurements powered by Kaiser Raman
technology.
|
Taal: |
Engels |
|
Versie: |
07/01/2025 |
|
Bestandsgrootte: |
499.4 KB |
|
Bestandsnaam: |
PU01444CEN_0225.pdf |
This paper presents experimental findings that validate the performance
of an Endress+Hauser Raman spectroscopic analyzer in accurately
measuring parahydrogen conversion during the hydrogen liquefaction
process.
|
Taal: |
Engels |
|
Versie: |
13/01/2026 |
|
Bestandsgrootte: |
416 KB |
|
Bestandsnaam: |
PU01623CEN_0126.pdf |
A guide to our Raman spectroscopy analyzer and probe portfolio, powered
by Kaiser Raman technology, for composition analysis of gas streams and
LNG (includes the Raman Rxn4 analyzer, the Raman Rxn5 analyzer, the
Raman Rxn-30 probe, and Raman Rxn-41 probe) in the Oil & Gas,
Power & Energy, and Chemical industries.
|
Taal: |
Engels |
|
Versie: |
08/01/2026 |
|
Bestandsgrootte: |
2.5 MB |
|
Bestandsnaam: |
PU01445CEN_0326.pdf |