Ultrasonic measurement
Time-of-Flight
Prosonic FMU43
Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 15m
The Prosonic FMU43 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
-
Voordelen
Reliable non-contact measurement
Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
Envelope curves on the on-site display for simple diagnosis
Hermetically sealed and potted sensor
...
-
Toepassingsgebied
Two-wire or four wire instrument for continuous non-contact level and flow measurement.
Process connection: Flange
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: +0.7 to +2.5bar (+10 to +36psi)
Maximum measuring distance: Liquids 15m (50ft),...
Documenten / handleidingen / software
-
Prosonic M FMU40/41/42/43/44
Technical Information
Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials
Technische informatie (TI) -
Prosonic M FMU40/41/42/43/44
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
Inbedrijfsstellingsvoorschriften (BA) -
Prosonic M FMU40/41/42/43/44
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
Inbedrijfsstellingsvoorschriften (BA) -
Prosonic M FMU40/41/42/43/44
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
Inbedrijfsstellingsvoorschriften (BA) -
Prosonic M FMU40/41/42/43/44
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
Inbedrijfsstellingsvoorschriften (BA) -
Prosonic M FMU40/41/42/43
Wiring diagram
Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials
Short Instruction (KA)11/09Duits , Engels -
Prosonic M FMU40/41/42/43/44
4-20 mA HART
Brief Operating Instructions
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
Short Instruction (KA)09/11Engels -
Prosonic M FMU40/41/42/43/44
PROFIBUS-PA
Brief Operating Instructions
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
Short Instruction (KA)09/11Engels -
Prosonic M FMU40/41/42/43/44
FOUNDATION Fieldbus
Brief Operating Instructions
Compact transmitters for non-contact level measurements of fluids, pastes and coarse bulk materials
Short Instruction (KA)09/11Engels -
Ultrasonic level measurement
Ultrasonic level measurement
Short Instruction (KA)08/03Duits , Engels -
Weather protection cover
Mounting Instruction
Weather protection cover for devices with F12/T12/F23 housing.
Short Instruction (KA)06/07Duits , Engels , Spaans , fr , Italiaans , Nederlands -
Display VU331
Micropilot M, Levelflex M, Prosonic M, Micropilot S
Short Instruction (KA)01/16Duits , Engels -
Cable separate version
Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
Installatievoorschriften (EA) -
Sealing kit - installation instruction
Prosonic M
Installatievoorschriften (EA) -
Terminal module for housing F12/F23
Installation Instruction
Micropilot M, Levelflex M, Prosonic M
Installatievoorschriften (EA) -
Prosonic M FMU40/41/42/43/44
EAC:
2Ex nA IIC T6...T4 Gc X
Ex tc IIIC T95..115°C Dc X
Safety Instructions
Ultrasonic Level Measurement
Ex Veiligheidsinstructies (XA) -
Safety Instructions
Prosonic M FMU40, FMU41, FMU42, FMU43, FMU44
HART, PROFIBUS PA, FOUNDATION Fieldbus ATEX: II 3 G Ex nA IIC T6...T3 Gc (FMU40/41/42/44) II 3 D Ex tc IIIC Txx°C Dc (FMU40/41/42/43/44) IECEx: Ex nA IIC T6...T3 Gc (FMU40/41/42/44) EG 04 007; IECEx DEK 11.0014
Ex Veiligheidsinstructies (XA) -
Prosonic M FMU43
EAC:
Ex ta/tb IIIC T84...115°C Da/Db X
Ex ta/tc IIIC T84...104°C Da/Dc X
Safety Instructions
Ultrasonic Level Measurement
Ex Veiligheidsinstructies (XA) -
Prosonic M FMU43
EAC:
Ex ta/tb IIIC T84...115°C Da/Db X
Ex ta/tc IIIC T84...104°C Da/Dc X
Safety Instructions
Ultrasonic Level Measurement
Ex Veiligheidsinstructies (XA) -
Prosonic M FMU43
NEPSI:
Ex tD A20/21 IP6X T84°C...T104°C
Ex tD A20/22 IP6X T84°C...T104°C
Safety Instructions
Ultrasonic Level Measurement
Ex Veiligheidsinstructies (XA) -
Prosonic M FMU43
NEPSI:
Ex tD A20/21 IP6X T84°C...T115°C
Ex tD A20/22 IP6X T84°C...T104°C
Safety Instructions
Ultrasonic Level Measurement
Ex Veiligheidsinstructies (XA) -
Safety Instructions
Prosonic M FMU43
PROFIBUS PA, FOUNDATION Fieldbus ATEX: II 1/2 D Ex ta/tb IIIC T84°C Da/Db II 2 D Ex tb IIIC T84°C Db II 1/3 D Ex ta/tc IIIC T84°C Da/Dc II 3 D Ex tc IIIC T84°C Dc IECEx: Ex ta/tb IIIC T84°C Da/Db Ex tb IIIC T84°C Db Ex ta/tc IIIC T84°C Da/Dc KEMA 02 ATEX 1018; IECEx DEK 11.0014
Ex Veiligheidsinstructies (XA) -
Safety Instructions
Prosonic M FMU43
HART ATEX: II 1/2 D Ex ta/tb IIIC T115°C Da/Db II 2 D Ex tb IIIC T115°C Db II 1/3 D Ex ta/tc IIIC T84°C Da/Dc II 3 D Ex tc IIICT84°CDc IECEx: Ex ta/tb IIIC T115°C Da/Db Ex tb IIIC T115°C Db Ex ta/tc IIIC T84°C Da/Dc KEMA 02 ATEX 1018; IECEx DEK 11.0014
Ex Veiligheidsinstructies (XA) -
Safety Instructions
Micropilot M, Levelflex M, Prosonic M
FM Control Drawing EMC C-module for ToF apparatus Cl. I, II, III, Div. 2, Group A, B, C, D, E, F, G and Cl. I, Zone 2, Group IIC NIFW installation
Ex Veiligheidsinstructies (XA) -
Grounding of screen variations
Screen grounding
Certificaat FM/CSA (ZD) -
Interoperability Statement: Prosonic M, FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation Integrated Architecture-based host system Allen-Bradley ControlLogix. Prosonic M, FOUNDATION fieldbus Level Transmitter, Device Revision: 4, DD Revision: 1, Device ID: 0x1011, Software Revision:4.00
Speciale Documentatie (SD) -
Interoperability Statement: Prosonic M, HART
Endress+Hauser field device has been tested with Rockwell Automation Integrated Architecture-based host system Allen-Bradley ControlLogix. Prosonic M, HART Level Transmitter, Device Revision: 2, Device ID: 0x11, Software Revision: 1.02.00
Speciale Documentatie (SD) -
Interoperability Statement: Prosonic M, FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation Integrated Architecture-based host system Allen-Bradley ControlLogix. Prosonic M, FOUNDATION fieldbus Level Transmitter, Device Revision: 3, DD Revision: 3, Device ID: 0x1011, Software Revision: 2.04
Speciale Documentatie (SD) -
Prosonic M: FMU40, FMU41, FMU42, FMU43
Manufacturer information for users regarding software updates (NE53)
Prosonic M: FMU40, FMU41, FMU42, FMU43 Software version V 1.04.00 PA
Fabrikanten Informatie (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.14.00
Fabrikanten Informatie (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.12.00
Fabrikanten Informatie (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.08.00
Fabrikanten Informatie (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.12.00
Fabrikanten Informatie (MI) -
Prosonic M FMU4x
Manufacturer Information for users regarding software updates (NE53)
Software version V01.04.00 HART and PROFIBUS PA
Fabrikanten Informatie (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.05.00
Fabrikanten Informatie (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.06.00
Fabrikanten Informatie (MI) -
Level measurement
Product overview for applications in liquids and bulk solids
Branches (FA)03/17Engels -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Branches (FA)03/17Duits -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des solides en vrac
Branches (FA)03/17fr -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Branches (FA)03/17Spaans -
Level measurement
Product overview for applications in liquids and bulk solids
Branches (FA)03/17Engels -
Prosonic M Ultrasonic Level via PROFIBUS PA to the PlantPAx Process
Automation System
System using a 1788HP-EN2PAR Linking Device Integration Document
Systeem Partner (SP)01/13Engels -
Prosonic M Ultrasonic Level via HART to the PlantPAx Process Automation
System
System using a ControlLogix 1756 HART Analog Input Module Integration Document
Systeem Partner (SP)01/09Engels -
GSD Single, GSD_EH_PA_LE_Prosonic_0x152C_V01_00_PALIB, 14.04.2014 (Level,
Prosonic M, 0x152C)
PROFIBUS PA, PROFIBUS System Version: Any
General Station Description (GSD)1.00.00Language neutral -
EDD Library, PDM_HA_LE_Package_V_1_14_00, 06.08.2015 (Level)
HART, PDM Version: 5.2 SP1, 6.0 SP5, 6.1, 8.1, 8.1 SP1, 8.2, 8.2 SP 1
Electronic Data Description (EDD)1.14.00Language neutral -
EDD Library, PDM_PA_Level_Package_V_1_12_00, 30.07.2015 (Level)
PROFIBUS PA, PDM Version: 6.0 SP3, 6.0 SP4, 6.0 SP5, 6.1, 8.1, 8.1 SP 1
Electronic Data Description (EDD)1.12.00Language neutral -
EDD Single, EH_FF_LE_ProsonicM_0x1011_0x04_0x01_FFLIB_ITK4_61, 09.11.2016
(Level, Prosonic M, 0x101
FOUNDATION Fieldbus H1, FOUNDATION fieldbus System Version: ITK 4.61
Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_ProsonicM_0x0011_0x02_0x01, 07.11.2018 (Level, Prosonic M, 0x0011)
HART, PDM Version: 6.0 SP5
Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_ProsonicM_0x1011_0x03_0x03_FFLIB_ITK4_60, 09.11.2016
(Level, Prosonic M, 0x101
FOUNDATION Fieldbus H1, FOUNDATION fieldbus System Version: ITK 4.60
Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_ProsonicM_0x1011_0x04_0x02_FFLIB_ITK5_00, 09.11.2016
(Level, Prosonic M, 0x101
FOUNDATION Fieldbus H1, FOUNDATION fieldbus System Version: ITK 5.00
Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_ProsonicM_0x1011_0x04_0x03_FFLIB_ITK5_20, 09.11.2016
(Level, Prosonic M, 0x101
FOUNDATION Fieldbus H1, FOUNDATION fieldbus System Version: ITK 5.20
Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_ProsonicM_0x0011_0x04_0x01, 07.11.2018 (Level, Prosonic M, 0x0011)
HART, PDM Version: 6.0 SP5
Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_ProsonicM_0x1011_0x03_0x01_FFLIB_ITK4_01, 09.11.2016
(Level, Prosonic M, 0x101
FOUNDATION Fieldbus H1, FOUNDATION fieldbus System Version: ITK 4.01
Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicM_FMU4x_PA_V2_04, 04.12.2017 (Level, Prosonic M, 0x152C)
PROFIBUS PA, DeviceCare Version: 1.04.00 FieldCare Version: 2.12.00
Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, ProsonicM_FMU4x_PA_V2_00___2_02, 04.12.2017 (Level, Prosonic M, 0x152C)
PROFIBUS PA, DeviceCare Version: 1.04.00 FieldCare Version: 2.12.00
Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, ProsonicM_FMU4x_PA_V2_06, 04.12.2017 (Level, Prosonic M, 0x152C)
PROFIBUS PA, DeviceCare Version: 1.04.00 FieldCare Version: 2.12.00
Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, ProsonicM_FMU4x_PA_V4_xx, 04.12.2017 (Level, Prosonic M, 0x152C)
PROFIBUS PA, DeviceCare Version: 1.04.00 FieldCare Version: 2.12.00
Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, ProsonicM_FMU4x_V2_00, 01.12.2017 (Level, Prosonic M, 0x0011)
HART, DeviceCare Version: 1.04.00 FieldCare Version: 2.12.00
Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicM_FMU4x_V4_xx, 01.12.2017 (Level, Prosonic M, 0x0011)
HART, DeviceCare Version: 1.04.00 FieldCare Version: 2.12.00
Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_FF_Package_Level_1_05_00, 29.05.2018 (Level)
FOUNDATION Fieldbus H1, Plant Resource Manager Version: R3.02, R3.12
Faceplate1.05.00Language neutral -
Animation Measuring Principle Time-of-Flight
Animation FR mp4 1280x720
Animatie08/13fr -
Animation Measuring Principle Time-of-Flight
Animation FR flv 480x270
Animatie08/13fr -
Animation Measuring Principle Time-of-Flight
Animation ES mp4 1280x720
Animatie05/13Spaans -
Animation Measuring Principle Time-of-Flight
Animation ES flv 480x270
Animatie05/13Spaans -
Animation Measuring Principle Time-of-Flight
Animation EN flv 480x270
Animatie04/13Engels -
Animation Measuring Principle Time-of-Flight
Animation DE flv 480x270
Animatie04/13Duits -
Animation Measuring Principle Time-of-Flight
Animation DE mp4 1280x720
Animatie04/13Duits -
Animation Measuring Principle Time-of-Flight
Animation EN mp4 1280x720
Animatie04/13Engels -
Animation Measuring Principle Time-of-Flight
Animation TR mp4 1920x1080
Video08/17Turks -
Waterpilot, Spare Parts Level, Soliphant T, Prosonic M, Minicap, Liquipoint T, Liquiphant M, Liquiphant, Levelflex, Deltapilot M, Cerabar M
Productcode: FTL51C-, FTL51H-, FTM20-, FTM21-, FTW31-, FTW32-, OTC260-, OTC262-, OTL50-, OTL50H-, OTL51-, OTL51C-, OTL51H-, OTM20-, OTM21-, OTW31-, OTW32-, PMC51-, PMP51-, FTL51-, FTL50H-, FTL50-, FTL33-, FTL31-, FTC262-, FTC260-, FMX21-, FMU43-, FMU42-, FMU41-, FMU40-, FMP57-, FMP51-, FMP50-, FMB52-, FMB51-, FMB50-, FHX40- verklaring Number: HE_00716_02.17 Specificatie van de fabrikant: RoHS
Manufacturer DeclarationDuits , Engels -
Prosonic M
Productcode: FMU43- verklaring Number: HE_00613_01.17 Specificatie van de fabrikant: RoHS
Manufacturer DeclarationChinees -
Prosonic M
Productcode: FMU43- verklaring Number: HE_00608_01.17 Specificatie van de fabrikant: RoHS
Manufacturer DeclarationChinees -
Prosonic M
Productcode: FMU40-, FMU41-, FMU42-, FMU43-, FMU44-
EU DeclarationDuits , Engels , fr -
Prosonic M
Productcode: FMU43- verklaring Number: KEMA02ATEX1018
EU DeclarationDuits , Engels -
Soliphant T, Soliphant M, Solicap S, Solicap M, Prosonic S, Prosonic M, Nivector, Minicap, Micropilot, Levelflex
Productcode: FTM52-, FTM51-, FTM50-, FTM21-, FTM20-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC968-, FTC262-, FTC260-, FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMR67-, FMR57-, FMR56-, FMP57-, FMP56-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Regio: Russia (Declaration of Conformity) Keurnummer: RU D-DE.MO10.B.05551
MiscellaneousRussisch -
Prosonic M, Prosonic T
Productcode: FMU30-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44- Regio: China Keuringsinstantie: ACMA Keurnummer: EC12010A
MiscellaneousEngels -
Prosonic M, Prosonic S, Prosonic T
Productcode: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91-, FDU90- Regio: Russia (TR CU) Keuringsinstantie: EAC Keurnummer: TC BY_112 11.01. TP020 003 127
MiscellaneousRussisch -
Soliphant T, Soliphant M, Solicap S, Solicap M, Prosonic S, Prosonic M, Nivector, Minicap, Micropilot, Levelflex
Productcode: FTM52-, FTM51-, FTM50-, FTM21-, FTM20-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC968-, FTC262-, FTC260-, FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMR67-, FMR57-, FMR56-, FMP57-, FMP56-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Regio: Russia (Declaration of Conformity) Keurnummer: RU D-DE.MO10.B.05554
MiscellaneousRussisch -
Prosonic M, Prosonic S
Productcode: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95- Regio: Russia (TR CU) Keuringsinstantie: EAC Keurnummer: TС RU D-DE.MU62.B.02534
MiscellaneousRussisch -
Prosonic M, Prosonic S
Productcode: FDU90-, FDU91-, FDU92-, FDU93-, FDU95-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95- Regio: Russia (TR CU) Keuringsinstantie: EAC Keurnummer: TC № RU D-DE.AL32.B.07214
MiscellaneousRussisch -
Prosonic M
Productcode: FMU43- Regio: Europe (ATEX) Keuringsinstantie: KEMA Catagorie: II 3 D, II 1/2 D, II 1/3 D Bescherming: Ex ta/tc IIIC Txxx°C Da/Dc, Ex ta/tb IIIC Txxx°C Da/Db, IIIC Txxx°C Dc
Explosion ProtectionDuits , Engels -
Prosonic M
Productcode: FMU44-, FMU43-, FMU42-, FMU41-, FMU40- Regio: Canada, USA Keuringsinstantie: CSA Catagorie: CL. I, II, III, 1 ABCDEFG Bescherming: GP, Ex ia, Ex d
Explosion ProtectionEngels -
Prosonic M
Productcode: FMU40-, FMU41-, FMU42-, FMU43- Regio: Brazil Keuringsinstantie: TÜV Bescherming: Ex d [ia], Ex e mb [ia], Ex ia
Explosion ProtectionPortugees -
Prosonic M, Prosonic S, Prosonic T
Productcode: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Regio: Russia (TR CU) Keuringsinstantie: EAC Bescherming: Ex d [ia], Ex ia, Ex m, Ex nA, Ex t, Ex ta/tc, Ex ta/tb
Explosion ProtectionRussisch -
Prosonic M
Productcode: FMU43- Regio: China Keuringsinstantie: NEPSI Bescherming: Ex tD A20/A21 IP6X Txxx°C, Ex tD A20/A22 IP6X Txxx°C
Explosion ProtectionChinees -
Prosonic M
Productcode: FMU40-, FMU41-, FMU42-, FMU43-, FMU44- Regio: Europe Keuringsinstantie: Endress+Hauser Catagorie: II 3 D, II 3 G Bescherming: Ex nA IIC T6...T3 Gc, Ex t IIIC Txxx°C Dc
Explosion ProtectionDuits , Engels , fr -
Prosonic M
Productcode: FMU40-, FMU41-, FMU42-, FMU43-, FMU44- Regio: International (IECEx) Keuringsinstantie: IECEx Bescherming: Ex d [ia] IIC T6...T4 Ga/Gb, Ex ia IIC T6...T4 Ga/Gb, Ex ta/tc IIIC Txxx°C Da/Dc, Ex ta/tb IIIC Txxx°C Da/Db
Explosion ProtectionEngels -
Product Family: Prosonic M
Productcode: FMU40-, FMU41-, FMU42-, FMU43- Regio: International Keuringsinstantie: Fieldbus Foundation Software Version: DEVICE REV. 04, DD-ITK 5.20
Fieldbus ConformanceEngels -
Product Family: Prosonic M
Productcode: FMU43-, FMU41-, FMU42-, FMU40- Regio: International Keuringsinstantie: PI, PROFIBUS International Software Version: PROFILE 3.0
Fieldbus ConformanceEngels -
Micropilot S, Liquiphant S, Levelflex, Micropilot, Liquiphant M, Minicap, Nivector, Prosonic M, Prosonic S, Prosonic T, Pumpenschutz, Solicap M, Solicap S, Soliphant M, Soliphant T, SYSTEM, Liquipoint T, Liquipoint, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Einstabsonde, Dreistabsonde, Doppelstabsonde
Productcode: FTL51-, FMP54-, FMP52-, FMR52-, FMR54-, FMP57-, FMP55-, FMP51-, FMR51-, FMR57-, FMP53-, FMR56-, FMP56-, FMR53-, FMR50-, FMP50-, FMU41-, FMU42-, FTL51H-, FTL50H-, FMU43-, FMU44-, FTL51C-, FTL70-, FMU40-, FMI52-, FTL50-, FTL71-, FTM51-, FTI52-, FMR532-, FTL81-, FMI51-, FMR533-, FTI51-, FTL85-, FTM52-, FTL33-, FTL31-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC262-, FTC260-, FTL80-, FTM20-, FTM21-, FTM50-, FTW23-, FTW31-, FTW32-, FTW33-, FTW360-, NMR84-, NMR81-, 11263-, 11362Z-, 11363Z-, 11375Z-, 11961Z-, FDU90-, FDU91-, FDU91F-, FDU92-, FDU95-, FDU96-, FDU93-, FMI21-, FMU30-, FMR540-, FMR530-, FMR10-, FMR20- Keuringsinstantie: TÜV
Pressure EquipmentDuits , Engels -
Prosonic M, Prosonic S, Prosonic T
Productcode: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91-, FDU90- Regio: Belarus Keuringsinstantie: BEL Keurnummer: 9773
MetrologyRussisch -
Prosonic M, Prosonic S, Prosonic T
Productcode: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90- Regio: Kazakhstan Keuringsinstantie: KazInMetr Keurnummer: 12134
MetrologyRussisch -
Prosonic M, Prosonic S
Productcode: FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95- Regio: Russia (GOST) Keuringsinstantie: Rosstandart Keurnummer: DE.C.29.004.A № 50999
MetrologyRussisch
Accessoires / Spare parts
-
-
Order code 52006628
Instrument plug M20-M12 "PA" (WDM)150
Aansluiting: M20 wartel Verbinding: M12 connector met leads 0,75 mm2, lengte 150 mm Pin aansluiting A: PA- S: Screen B: PA+ n.c.: Niet aangesloten
-
-
-
Nr 12 Order code 535720-9020
Set of screws housing F12/T12/F23
Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.
-
-
-
Nr 65 Order code 52010526
FMP-M O ringenset
Consists of: 1x O-ring 113.9x3.53 EPDM. 1x O-ring 72.0x3.0 EPDM. 1x O-ring 49.21x3.53 EPDM. 1x flat gasket 47x58x2 EPDM. 1x flat gasket 59x68x2.5 EPDM. 2x O-ring 17.0x2.0 EPDM. Usage: FMU40/FMU41/FMU42/ FMU43/FMU44.
-
-
-
Nr 20 Order code 517391-0011
Cover F12/T12 Alu, coated, gasket
Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.
-
Nr 20 Order code 52005936
FMR23x/24x deksel m.glas T12
Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.
-
-
-
Nr 11 Order code 52006026
FMX-M DEKSEL F12, AANSLUITRUIMTE
Overkapping voor uiteinde Micropilot M, Prosonic M, Levelflex M
-
Nr 11 Order code 52019062
Cover terminal compartment F12/F23,FHX40
Hood terminal compartment. Usage: separate display, Micropilot M, Prosonic M, Levelflex M.
-
-
-
Order code 71092209
-
-
-
Nr 35 Order code 52012156
FMP-M F12 aansluitmodule PA en FF
PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.
-
Nr 35 Order code 52013304
FMP40 voeding voor 4 dr. 10,5..32 V DC
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52013305
FMP40 voeding voor 4 dr 90..250 V AC
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52015585
Power supply CSA, 10.5-32VDC (housg F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52015586
Power supply CSA, 90-250VAC (housg F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
-
-
Nr 30 Order code 71025602
FMU4x elektronika 4 dr. HART V4.0
4-20mA, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.
-
Nr 30 Order code 71025603
FMU4x elektronika PA V4.0
PROFIBUS PA, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.
-
Nr 30 Order code 71025604
Electronica FMU4x,Ex,FF,V4.0
FOUNDATION Fieldbus, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.
-
-
-
Nr 40 Order code 52026443
FMX-M BEDIENINGSMODULE VU331
4-Lijns alfanumerische weergave. Gebruik: FMR530/532/533, FMR540, FMU40/41/42/43/44.
-
-
-
Order code FHX40-
Display FHX40
Remote display + lokale bediening. 4-regelig LC-display. :: Menu-bediening van platte tekst. :: Eenvoudige installatie. :: Gebruikerstaal selecteerbaar. :: Weergave envelopcurve ter plaatse. Gebruik:FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.
-
-
-
Nr 50 Order code 52013543
-
-
-
Order code
Screw in flange FAX50 please order with separat order structure.
-
Order code 52016334
-
Order code 942666-0000
Mounting bracket FAU20
Material: 316Ti. Usage: mounting FMU42/FMU43/FMU44.
-
Order code 942668-0000
Mounting bracket FAU 20_316TI
-
Order code 71020502
-
Order code 71020503
-
Order code 71020504
-
Order code 543199-0001
Protective cover for housing T12/F12, SS
Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.
-
Order code 71007843
ToF Adapter FXA291
Gebruik: aansluiting Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, Commubox FXA291.
-
Order code 71000221
Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60
Verbinding RS232(52013675)/ ToF adapter FXA291 (71007843). Gebruik: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.
-
Order code 52013874
-
-
Voorganger