Hydrostatic
Level measurement
Deltapilot FMB51

Deltapilot FMB51 rod version ©Endress+Hauser

Pressure measuring principle

Deltapilot FMB51 ©Endress+Hauser

Pressure sensor with the Contite measuring cell for hydrostatic level measurement

The Deltapilot FMB51 is a rod version with a fixed process connection. This device with the Contite measuring cell and is typically used in the environmental industry. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

  • Voordelen

    • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

    • Modular concept for easy replacement of display or electronics

    • Seamless and independent system...

  • Toepassingsgebied

    For level measurement.

    • Process connections: Threads and flanges

    • Temperature: -10 to +85°C (14°F…185° F)

    • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)

    • Accuracy: ±0.2%, ±0.1% (option)

    • International explosion protection...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Hydrostatic pressure

  • Characteristic

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Rod version

  • Supply voltage

    4...20 mA HART

    10,5...45 VDC (Non Ex):

    Ex ia: 10,5...30 VDC

    PROFIBUS PA:

    9...32 VDC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 VDC (Non Ex)

  • Reference Accuracy

    Standard 0,2%
    Optional 0,1%

  • Long term stability

    0,05% of URL/year

  • Process temperature

    -10°C...85°C
    (14°F…212°F)

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Measuring cell

    100 mbar...10 bar
    (1.5 psi...150 psi)

  • Smallest calibratable span

    10 mbar (1.45 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. Turn down

    100:1

  • Max. overpressure limit

    40 bar (600 psi)

  • Process connection

    Thread:

    G1 1/2, MNPT1 1/2

    Flange:

    DN40...DN100,

    ASME 2"...4",

    JIS 10K

  • Material process membrane

    316L, AlloyC

    Gold-Rhodium

  • Material gasket

    Viton, EPDM, Kalrez, none

  • Fill fluid

    Inert oil,

    Synthetic oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175

  • Drinking water approvals

    KTW/ NSF

  • Specialities

    Modularity to differential pressure and process pressure devices (replacable display, universal electronics)

    Diagnostic functions

    Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)

  • Meetprincipe

    Hydrostatic

  • Characteristic / Application

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Rod version

  • Specialities

    Modularity to differential pressure and process pressure devices (replacable display, universal electronics)

    diagnostic functions

    Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC (Non Ex)

  • Accuracy

    Standard 0,2%
    Optional 0,1%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Process temperature

    -10°C...85°C
    (14°F…212°F)

  • Process pressure absolute / max. overpressure limit

    40 bar (600 psi)

  • Pressure measuring range

    100mbar...10bar
    (1.5psi...150psi)

  • Main wetted parts

    Alloy C
    316L
    optional coating AuPt

  • Process connection

    Thread:

    G1 1/2, MNPT1 1/2

    Flange:

    DN40...DN100,

    ASME 2"...4",

    JIS 10K

  • Max. measurement distance

    100m (328ft) H2O

  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

    NACE MR0175

  • Drinking water approvals

    KTW/ NSF

  • Options

    Separate housing
    Initial device settings
    Overvoltage protection

  • Application limits

    If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP)
    Observe ratio head pressure : hydrostatic pressure

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 19
    • Nr 19 Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Bestaat uit: Vent schroef 304, compensatie druk filter, O-ring EPDM, dekseltje. Gebruik: Huisvesting T14, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD72. Behuizing F31, FMB50/51/52/53, PMC51, PMP51/PMP55. Behuizing F15 w / o B1, BB, BD, BF, GA, ID, I1, FMB50/51/52/53, PMC51, PMP51/PMP55.

    • Nr 19 Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Bestaat uit: Vent schroef 304, compensatie druk filter, O-ring VMQ, dekseltje. Usage: Huisvesting T17, PMC71, PMP71 / PMP75, PMD70/PMD75, FMD76/FMD77/FMD78. Huisvesting F15 voor B1, BB, BD, BF, GA, ID, I1, FMB50/51/52/53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Order code 52027000

      Deksel voor 316L F15 behuizing

      Met dichtring 67,5x2,9x1,5, VMQ/PTFE voor RVS behuizing F15

    • Nr 20 Order code 52027002

      Cover F15 316L, sight glass, gasket

      Sight glass: glass. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15, stainless steel.

    • Nr 20 Order code 52028207

      Cover F15, sight glass PC, 316L, gasket

      Display glas van polycarbonaat Afdichtingsring 67,5x2,9x1,5 VMQ/PTFE Voor gebruik in explosie veilig gebied Geen ATEX RSV huis F15

    • Nr 20 Order code 52028267

      Cover F15 316L,claw,sight glass,gasket

      Sight glass glass. Cover claw. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: dust Ex version, housing F15 stainless steel, FMB50/FMB51/FMB52/FMB53. PMC51, PMP51/PMP55.

    • Nr 20 Order code 52028268

      FTI51/52 deksel F15 behuizing

      Cover claw. Gasket 67,5x2,9x1,5, VMQ/PTFE. Usage: Housing F15 Stainless Steel, Cerabar M, Deltapilot M.

    • Nr 20 Order code 71092705

      Deksel F30/31 Alu, pakking

      Material: Aluminium. O-ring: EPDM. Not for Ex d/XP. Usage: FTC260/FTC262, PMC51, PMP51/PMP55, PMD55, FMB50/FMB51/FMB52/FMB53.

    • Nr 20 Order code 71092707

      Cover F30/31 Alu, sight glass, gasket

      Material: Aluminium. Sight glass: Mineral glass. O-ring: EPDM. Not for Ex d/XP. Usage: FTC260/FTC262, PMC51, PMP51/PMP55, PMD55, FMB50/FMB51/FMB52/FMB53.

  • 21
    • Nr 21 Order code 52020429

      Dichtingsset EPDM, deksel T14, 5 stuks

      Bestaat uit: 5x O-ring 75,87x2.62, EPDM,PTFE,FDA. Gebruik: Huisvesting 30/F31/F34,T14/T15.

    • Nr 21 Order code 52028179

      Afdichting 67,5x2,9x1,5 VMQ/PTFE 5st.

      Geprofileerde dichtringen voor deksel van RVS F15 behuizing.

  • 15
    • Nr 15 Order code 52002449

      PMC4x wartel M201,5 compleet

      Bestaat uit: kabelwartel M20x1.5 pakking NBR stop Pg13.5 voor CERABAR M

    • Nr 15 Order code 52005984

      Plug 3p M12/M20, pakking

      Consists of: terminal block, gasket. Usage: FMB50/51/52/53, PMC51, PMD55, PMP51/55.

    • Nr 15 Order code 52020762

      Plug 2/7-pole, HAN7D, gasket

      Bestaat uit: harting plug set. Gebruik: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Order code 71092709

      Cable gland M20 PA, o-ring EPDM/PTFE

      Consists of: Cable gland M20, Synthetic. O-Ring 17,0x2,0 EPDM + PTFE/FDA. Usage: Housing F30/31 PMC51, PMP51/55, FMB50/51/52/53, PMD55.

    • Nr 15 Order code 71092711

      Cable gland M20 Metal, gasket

      Consists of: Cable gland M20, Metal. O-Ring 17,0x2,0 EPDM + PTFE/FDA. Usage: Housing F15/F31 PMC51, PMP51/PMP55, FMB50/FMB51/FMB52/FMB53. Housing F30 PMD55.

    • Nr 15 Order code 71092712

      Cable entry G1/2, gasket, adapter

      Consists of: gasket 18.72x2.51 NBR 70. Adapter M20 > G1/2. Not for Ex d. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.

    • Nr 15 Order code 71120017

      Plug valve, F30/F31, seal NBR

      Consists of: Plug, seal, screw. Usage: PMC51, PMP51/55, PMD55, FMB50/51/52/53.

    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD71/FMD72, FMD77/FMD78, FMB70,housing T14/T15/T17. PMC51, PMP51/PMP55, FMB50/FMB51/FMB52/FMB53, PMD55, housing F30/F31.

  • 40
    • Nr 40 Order code 71091670

      Display module VU340, Cbar/Dbar/Dpilot M

      Digitaal display, 3 druktoetsen, klembevestiging. Geschikt voor: PMD55, PMC51,PMP51/PMP55, FMB50/FMB51/FMB52/FMB53.

  • 30
  • 40
    • Nr 40 Order code 71094113

      Houder Display Dbar/Cbar/Dpilot M

      Geschikt voor: Display module VU340, PMD55, PMC51, PMP51/PMP55, FMB50/FMB51/FMB52/FMB53.

    • Order code 71220481

      Membran protection FMB51/52/53, 5 pieces

      Gebruik: FMB51/FMB52/FMB53.

    • Order code 71067434

      Modificatietypeplaat, non Ex

      Blanco. Te voorzien van een nieuwe typecodering wanneer een non Ex instrument gemodificeerd is.

    • Order code 71102216

      Montageset Cerabar,Deltapilot,Levelflex

      Materiaal: RVS 304. Geschikt voor: wand/pijp montage (2"), PMC71, PMP71/75, FMB70, PMC51, PMP51/55, FMB50/51/52/53. FMP50/51/52/53/54/55/56/57.

    • Order code 52024469

      Laspuntstuk G1-1/2, 316L

      Laspuntstuk G1-1/2 Materiaal: 316L Correcte installatie alleen met dummy. Gebruik:PMC71,PMP71,PMP75,FMB50/FMB51/ FMB52,FMB70,PMC51,PMP51/PMP55.

    • Order code 52024470

      Weld-in adapter G1-1/2, 316L, 3.1

      Montageproces aansluiting G1-1 / 2. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Gebruik: PMC71, PMP71, PMP75, FMB50/51/52, FMB70, PMC51, PMP51, PMP55.

    • Order code 52024471

      Weld-in dummy, adapter G1-1/2

      Ter voorkoming van vervorming tijdens het lassen van laspuntstuk 52024469 / 52024470.

    • Order code 52006263

      Connector M12x1,5 rechte uitvoering

      M12-aansluiting voor plug. Self confectionery connection. Gebruik: plug M12. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 52010285

      Kabel 4x0.34, box M12,Cu Sn/Ni,90°,L=5m

      M12 connector. 5m kabel PVC, Cu Sn / Ni-slot. Gebruik: FMB50/FMB51/FMB52/FMB53, FTL31/FTL33,FTW23,FTW33,PMC11,PMC21, PMC51,PMP11,PMP21/PMP23,PMP51/PMP55, PTC31B,PTP31B/PTP33B. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 71114212

      Plug connector M12 haaks

      Zelf-confectionerende aansluiting. Geschikt voor: plug M12. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 71043886

      Cable PE, L=2m/80inch, separate housing

      Aansluitkabel sensor>sep. housing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71043888

      Cable PE, L=5m/200inch, separate housing

      Aansluitkabel kabel sensor>sep.behuizing Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71043889

      Cable PE, L=10m/400inch,separate housing

      Aansluitkabel sensor> sep. huisvesting. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71070738

      Cable FEP, L=5m/200inch,separate housing

      Aansluitkabel sensor> sep. huisvesting. Gebruik: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.