Digital pressure transmitter with welded metal sensor for measurement in gases, steam or liquids

The Cerabar PMP71 digital pressure transmitter with metallic membrane is typically used in process applications for pressure, level, volume or mass measurement in liquids or gases. PMP71 is designed for high pressure applications up to 700bar. Quick Setup with freely adjustable measuring range without pressure specification. Designed according to IEC 61508 for use in SIL2/3 safety systems and available with MID Parts Certificate suitable for custody transfer applications.

  • Voordelen

    • Best accuracy, reproducibility and long-term stability

    • Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508

    • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

    • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

    • ...

  • Toepassingsgebied

    Two chamber aluminum or stainless steel (316L) housing.

    • Process connections: Threads and flange connections

    • Process temperature: -40 to +125°C (-40 to +257°F)

    • Measuring ranges: -1/0 up to 700bar (-15/0 up to +10,500psi)

    • Accuracy: ±0.05%, "Platinum" ±0.025%

    • International explosion...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Absolute and gauge pressure

  • Characteristic

    Digital transmitter with piezoresistive sensor and welded metallic membrane
    Modular transmitter
    Long term stability
    Enhanced safety via self diagnostic functionsSecondary process barrier

  • Supply voltage

    4...20 mA HART

    10,5...45V DC (Non Ex):

    Ex ia: 10,5...30V DC

    PROFIBUS PA:

    9...32 V DC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 V DC (Non Ex)

  • Reference Accuracy

    Standard: 0.05%

    Platinum: up to 0.025%

  • Long term stability

    0.05 % of URL/ year

    0.07 % of URL/ 5 years

    0.1 % of URL/ 10 years

  • Process temperature

    -40°C...125°C
    (-40°F...257°F)

  • Ambient temperature

    -50°C...85°C
    (-58°F...185°F)

  • Measuring cell

    100 mbar...700 bar
    (1.5 psi...10.500 psi)

    relative/ absolute

  • Smallest calibratable span

    5 mbar (0.075 psi)

  • Vacuum resistance

    10 mbar (0.15 psi)

  • Max. Turn down

    100:1

  • Max. overpressure limit

    1050 bar (15.750 psi)

  • Process connection

    Thread:

    G1/2...G2, R1/2, MNPT1/2...MNPT2, R1/2

    Flange:

    DN25...DN80,

    ASME 1"...4",

    JIS 10K...20K

  • Material process membrane

    316L, AlloyC,

    Rhodium> Gold

  • Material gasket

    None, measuring cell welded

  • Fill fluid

    Silicone oil,

    Inert oil

  • Material housing

    Die-cast aluminum,

    AISI 316L

  • Communication

    4...20 mA HART

    1- 5V DC Low Power

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175

  • Marine approvals

    GL/ABS

  • Drinking water approvals

    NSF

  • Specialities

    Diagnostic functions

  • Meetprincipe

    Absolute and gauge pressure

  • Characteristic / Application

    Digital transmitter with piezoresistive sensor and welded metallic membrane
    Modular transmitter
    Long term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Specialities

    diagnostic functionalities

    different languages in software

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    0,075%
    "PLATINUM" 0,05%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -50°C...85°C
    (-58°F...185°F)

  • Process temperature

    -40°C...125°C
    (-40°F...257°F)

  • Process pressure absolute / max. overpressure limit

    1050bar (15,750psi)

  • Pressure measuring range

    100mbar...700bar
    (1.5psi...10.500psi)

  • Main wetted parts

    Alloy C276
    316L
    Rhodium

  • Process connection

    Threads
    Flanges (DIN, ASME, ...) with flush membrane

  • Max. measurement distance

    7000m (22.966ft) H2O

  • Communication

    4...20 mA HART

    1- 5V DC Low Power

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

    NACE MR0175, MR0103

  • Marine approval

    GL/ ABS

  • Drinking water approvals

    NSF

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing
    Separate housing

  • Application limits

    Measuring cell: Metal
    welded
    If pressurized, possibly
    use differential pressure
    meas-urement with two
    pressure transmitters
    (electronic dp). Observe
    ratio head pressure :
    hydrostatic pressure

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 12
    • Nr 12 Order code 52020440

      Montageset behuizing / sensor

      Bestaat uit: 2x O-ring 45,69x2,62 EPDM. Behoudring, kunststof. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 12 Order code 71020596

      Mounting set housing T17 / sensor

      Bestaat uit: 2x O-ring 45,62x69x2,62 EPDM. 1x profielpakking 51.4x57.2x1.6 EPDM. Behoudring, kunststof. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

  • 13
    • Nr 13 Order code 52022418

      DELTABAR S(7X) 2 BEDIENINGS TOETSEN V2.0

      Bestaat uit: drukknop, deksel + schroeven. Gebruik: externe werking, FMB70, FMD76/FMD77/FMD78,PMC71, PMD70/PMD75,PMP71/PMP75.

    • Nr 13 Order code 52022419

      Push button housing, HART, version 1

      Bestaat uit: Drukknop, cover + schroeven. Kleur licht grijs. Gebruik: externe bediening, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Order code 52024110

      DELTABAR S (7X) 3 BEDIENINGSTOETSEN V2.0

      Bestaat uit: Drukknop, deksel + schroeven. Kleur donkergrijs. Gebruik: externe werking, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

  • 15
    • Nr 15 Order code 52020760

      Wartel M20x1.5, gasket

      Bestaat uit: Kabelwartel M20. O-ring 18.72x2.62 VMQ. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 15 Order code 52020761

      Cable entry G1/2, gasket, adapter

      Bestaat uit: Pakking 18,72x2,51 NBR. Adapter M20> G1/2. O-ring 18,77x1,78 NBR. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020762

      Plug 2/7-pole, HAN7D, gasket

      Bestaat uit: harting plug set. Gebruik: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Order code 52020763

      Plug 3-pole, M12, gasket

      Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Bestaat uit: Vent schroef 304, compensatie druk filter, O-ring EPDM, dekseltje. Gebruik: Huisvesting T14, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD72. Behuizing F31, FMB50/51/52/53, PMC51, PMP51/PMP55. Behuizing F15 w / o B1, BB, BD, BF, GA, ID, I1, FMB50/51/52/53, PMC51, PMP51/PMP55.

    • Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Bestaat uit: Vent schroef 304, compensatie druk filter, O-ring VMQ, dekseltje. Usage: Huisvesting T17, PMC71, PMP71 / PMP75, PMD70/PMD75, FMD76/FMD77/FMD78. Huisvesting F15 voor B1, BB, BD, BF, GA, ID, I1, FMB50/51/52/53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Order code 52020432

      Deksel T14/T15 Alu, dichting

      Materiaal: aluminium, gecoat. O-ring EPDM, FDA. Niet voor EEx d/XP. Gebruik: FMB70,FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 52020433

      Cover T14/T15 Alu, Ex d, gasket

      Materiaal: aluminium, gecoat. O-ring EPDM, FDA. EEx d/XP. Gebruik: FMB70,FMD71/FMD72/FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 20 Order code 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002774

      Deksel T17 316L, pakking

      Materiaal: 316L. Vlakke pakking EPDM, centreer ring, schroef. Niet voor EEx d/XP. Gebruik: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002810

      Cover T17 316L, sight glass, gasket

      Materiaal: 316L. Kijkglas: mineraalglas. Platte pakking EPDM, centrerende ring, schroef. Voor goedkeuring 2,3,4,7,8, Q, W. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75. Voor goedkeuring BC, BD,IB. Gebruik: FMD71/FMD72.

    • Nr 20 Order code 71002811

      Deksel T17 316L, met venster PC, o-ring

      Materiaal: 316L. Kijkglas: Polycarbonaat PC. Platte pakking EPDM, centrerende ring, schroef. Voor goedkeuring A,E,F,H,I,R,S,U,1,6. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75. Voor goedkeuring AA,BA,CA,CB,CC,CD,FA, FB,FD,IA. Gebruik: FMD71/FMD72.

    • Nr 20 Order code 71206965

      Cover T14 316L, Ex d, FVMQ

      Materiaal: 316L. O-ring EPDM, FVMQ. Individuele getest, EEx d / XP. Gebruik: PMC71, PMP71/PMP72/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD72.

    • Nr 20 Order code 71206968

      Cover T14 316L, Ex d, sight glass, FVMQ

      Materiaal: 316L. Kijkglas Mineraal glas. O-ring EPDM, FDA. Individuele getest, EEx d / XP. Gebruik: PMC71, PMP71/PMP72/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD72

  • 21
    • Nr 21 Order code 71206971

      Sealing set FVQM, T14,5 pcs.

      Bestaat uit: 5x O-ring 75,87 x2, 62 FVMQ. Gebruik: Huisvesting T14.

  • 20
    • Nr 20 Order code 71245247

      Cover T14/T15 Alu, sight glass, gasket

      Material: Aluminium, coated. Sight glass Mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD71/FMD72, FMB70.

    • Nr 20 Order code 71245249

      Cover T14/T15 Alu,Exd,sight glass,gasket

      Material: Aluminium. Sight glass Mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD71/FMD72.

    • Nr 20 Order code 71245250

      Cover T14 316L, Ex d, sight glass, EPDM

      Material: 316L. Sight glass Mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD71/FMD72.

  • 21
    • Nr 21 Order code 52020429

      Dichtingsset EPDM, deksel T14, 5 stuks

      Bestaat uit: 5x O-ring 75,87x2.62, EPDM,PTFE,FDA. Gebruik: Huisvesting 30/F31/F34,T14/T15.

    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD71/FMD72, FMD77/FMD78, FMB70,housing T14/T15/T17. PMC51, PMP51/PMP55, FMB50/FMB51/FMB52/FMB53, PMD55, housing F30/F31.

  • 25
    • Nr 25 Order code 52020432

      Deksel T14/T15 Alu, dichting

      Materiaal: aluminium, gecoat. O-ring EPDM, FDA. Niet voor EEx d/XP. Gebruik: FMB70,FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 52020433

      Cover T14/T15 Alu, Ex d, gasket

      Materiaal: aluminium, gecoat. O-ring EPDM, FDA. EEx d/XP. Gebruik: FMB70,FMD71/FMD72/FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 25 Order code 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 71002774

      Deksel T17 316L, pakking

      Materiaal: 316L. Vlakke pakking EPDM, centreer ring, schroef. Niet voor EEx d/XP. Gebruik: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Order code 71206965

      Cover T14 316L, Ex d, FVMQ

      Materiaal: 316L. O-ring EPDM, FVMQ. Individuele getest, EEx d / XP. Gebruik: PMC71, PMP71/PMP72/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD72.

  • 30
    • Nr 30 Order code 52024111

      Electronics HART Ex, ext. p.b., v2.0

      4-20mA, versie 2.0. Drukknop op de behuizing. Gebruik: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 52024400

      CERABAR-S/DELTABAR-S ELECTR.V20

      4-20mA, versie 2.0. Druk op de elektronica. Gebruik: FMD76/FMD77/FMD78,PMC71, PMD70/PMD75,PMP71/PMP75.

    • Nr 30 Order code 71026358

      FMB70 electr. bediening op elektronika

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, versie 02.10.zz. Drukknop op de behuizing. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 30 Order code 71196092

      Electronic HART Ex, v2.11

      4-20mA, versie 02.11.zz. Druk op de knop op elektronica. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78,FMB70. Niet voor MID delen certificaat (PMP71).

    • Nr 30 Order code 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, versie 2.11.zz. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70. Niet voor MID delen certificaat (PMP71).

    • Nr 30 Order code 71263933

      Electronics HART Ex, v2.20

      4-20 mA. Softwareversie 02.20.zz, HART 7, DevRev22. Drukknop op elektronica. Gebruik: PMC71,PMP71/PMP75, PMD75,FMD77/FMD78,FMB70. Niet voor MID onderdelen certificaat (PMP71).

    • Nr 30 Order code 71263934

      Electronics HART Ex, ext. p. b., v2.20

      4-20 mA. softwareversie 02.20.zz, HART 7, DevRev22. Drukknop op de behuizing. Gebruik: PMC71, PMP71 / PMP75, PMD75, FMD77 / FMD78, FMB70. Niet voor mariene certificaat. Niet voor MID onderdelen certificaat (PMP71)

    • Nr 30 Order code 71386147

      Elektronics HART Ex, v2.30

      4-20 mA. Softwareversie 02.30.zz, HART 7, DevRev23. Drukknop op elektronica. Gebruik: FMB70,FMD77/FMD78,PMC71, PMD75, PMP71/PMP75. Niet voor MID-onderdelencertificaat (PMP71).

    • Nr 30 Order code 71386153

      Electronics HART Ex, ext. p. b., v2.30

      4-20 mA. Softwareversie 02.30.zz, HART 7, DevRev23. Drukknop op behuizing. Gebruik: FMB70, FMD77/FMD78,PMC71, PMD75,PMP71/PMP75. Niet voor MID-onderdelencertificaat (PMP71).

    • Nr 30 Order code 52026762

      Upgrade electronics HART Ex, v2.1

      Bestaat uit: elektronica HART Ex, versie 2.1. Drukknop op de elektronica. Display behuizing. Gebruik: conversie-elektronica 1.0> 2.1, FMD76/FMD77/FMD78,PMC71, PMD70/PMD75,PMP71/PMP75.

    • Nr 30 Order code 52026763

      Upgrade electr. HART Ex,ext.push b.,v2.1

      Bestaat uit: elektronica HART Ex, versie 2.1. Druk op de knop extern. Drukknop, behuizing HART versie 2. Display behuizing. Gebruik: conversie-elektronica 1.0> 2.1, FMD76/FMD77/FMD78,PMC71,PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071824

      Elektronica PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware versie 02.00. Software versie 04.00.zz. Huidig verbruik 13mA + / - 1 mA. Drukknop op elektronica. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70.

    • Nr 30 Order code 71071825

      Electronics PA, ext. p. b.,HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071826

      Electronics FF, HW02.00, SW3.0

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071827

      Electronics FF, ext. p. b.,HW02.00,SW3.0

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71214057

      Electronics PA, Ex, HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardwareversie 02,00. Softwareversie 03.00.zz. Stroomverbruik 13mA + /-1mA. Druk op de knop op elektronica. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78.

    • Nr 30 Order code 71214064

      Electronics PA, ext. p.b.,HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardwareversie 02,00. Softwareversie 03.00.zz. Stroomverbruik 13mA + /-1mA. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78

    • Nr 30 Order code 71214066

      Electronics FF, ext. p.b.,HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardwareversie 02,00. Softwareversie 02.00.zz. Stroomverbruik 15mA + /-1mA. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78

    • Nr 30 Order code 71214069

      Electronics FF, HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardwareversie 02,00. Softwareversie 02.00.zz. Stroomverbruik 15mA + /-1mA. Druk op de knop op elektronica. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78.

    • Nr 30 Order code 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware-versie 02.00. software versie 04.00.zz, FF, DevRev07. Stroomverbruik 15mA +/- 1 mA. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70. Niet voor mariene certificaat en SIL.

    • Nr 30 Order code 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware-versie 02.00. software versie 04.00.zz, FF, DevRev07. Stroomverbruik 15mA +/- 1 mA. Drukknop op elektronica. Gebruik: PMC71, PMP71/PMP75,PMD70/PMD75, FMD76/FMD77/FMD78,FMB70. Niet voor SIL.

    • Nr 30 Order code 71224775

      Electronics PA, HW02.00, SW4.01

      PROFIBUS PA, Ex. Hardware-versie 02.00. software versie 04.01.zz,PROFIBUS PA, Profile 3,02, DevRev03. Stroomverbruik 13mA +/- 1 mA. Drukknop op elektronica. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70. Niet voor de scheepvaart certificaat.

    • Nr 30 Order code 71224776

      Electronics PA, ext.p. b.,HW02.00,SW4.01

      PROFIBUS PA, Ex. Hardware-versie 02.00 software versie 04.01.zz, PROFIBUS PA, Profile 3,02, DevRev03. Stroomverbruik 13mA +/- 1 mA. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70.Niet voor de scheepvaart certificaat.

    • Nr 30 Order code 71327714

      Electronics 1-5VDC Low Power

      Usage: PMP71. Approval: V,T,X.

  • 31
    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostische software inbegrepen. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

  • 35
    • Nr 35 Order code 52020434

      Terminal 3-pole, RFI, HART, TIIS

      RFI-filter. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75, TIIS Ex ia.

    • Nr 35 Order code 52026605

      Terminal 2-pole, RFI, PA, TIIS

      RFI filter. PROFIBUS PA. Gebruik: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.

    • Nr 35 Order code 52027691

      Terminal 2-pole, RFI, FF, Ex

      RFI-filter. FOUNDATION Fieldbus. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 35 Order code 71028473

      Terminal 3p., RFI, HART, OVP, TIIS

      Overspanningsbeveiliging, RFI-filter. Gebruik: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028475

      Uiteinde 2-polig, RFI, PA, OVP, Ex

      Overspanningsbeveiliging, RFI-filter. PROFIBUS PA. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70.

    • Nr 35 Order code 71028476

      Terminal 2-pole, RFI, FF, OVP, Ex

      Overspanningsbeveiliging, RFI-filter. FOUNDATION Fieldbus. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 35 Order code 71121574

      Terminal 2-pole, RFI, PA, Ex

      RFI filter. PROFIBUS PA. Gebruik: FMB70, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, Niet voor TIIS

    • Nr 35 Order code 71191892

      Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd

      RFI-filter. Gebruik: PMC71,PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70,FMD71/FMD72. Niet voor TIIS Ex ia, TIIS Ex d.

    • Nr 35 Order code 71191894

      Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd

      Overspanningsbeveiliging, RFI-filter. Gebruik: PMC71/PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70,FMD71/FMD72. Niet voor TIIS Ex ia, TIIS Ex d.

    • Nr 35 Order code 71327712

      Terminal 3-pole, 1-5VDC electronics

      Usage: PMP71.

  • 40
    • Nr 40 Order code 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digitaal display, 3 drukknoppen, Gebroken beugel. Talen DE/EN/FR/ES/IT/NL, Van software versie 02.00.zz; Gebruik: elektronica HART. Talen DE/EN/FR/ES/IT/NL/JA/ZH. Van software versie 02.01.zz; Elektronica HART. Talen DE/EN/FR/ES/IT/JA/ZH/RU, Van software versie 02.11.zz; Elektronica HART. Van software versie 04.00.zz; Elektronica PROFIBUS PA. Van software versie 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70,FMD76/FMD77/FMD78,PMC71, PMD70/PMD75,PMP71/PMP72/PMP75. Van software versie 01.00.zz; Elektronica HART, FMD71/FMD72.

    • Order code 52009800

      Vlakke pakking 18,5x23,9x1,5 FKM, 5 stuk

      Proces gasket Viton. Gebruik: Cerabar M/S, Cerabar PMP11/PMP21, metaal cel.

    • Order code 71102216

      Montageset Cerabar,Deltapilot,Levelflex

      Materiaal: RVS 304. Geschikt voor: wand/pijp montage (2"), PMC71, PMP71/75, FMB70, PMC51, PMP51/55, FMB50/51/52/53. FMP50/51/52/53/54/55/56/57.

    • Order code 71043886

      Cable PE, L=2m/80inch, separate housing

      Aansluitkabel sensor>sep. housing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71043888

      Cable PE, L=5m/200inch, separate housing

      Aansluitkabel kabel sensor>sep.behuizing Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71043889

      Cable PE, L=10m/400inch,separate housing

      Aansluitkabel sensor> sep. huisvesting. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71070738

      Cable FEP, L=5m/200inch,separate housing

      Aansluitkabel sensor> sep. huisvesting. Gebruik: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 52024469

      Laspuntstuk G1-1/2, 316L

      Laspuntstuk G1-1/2 Materiaal: 316L Correcte installatie alleen met dummy. Gebruik:PMC71,PMP71,PMP75,FMB50/FMB51/ FMB52,FMB70,PMC51,PMP51/PMP55.

    • Order code 52024470

      Weld-in adapter G1-1/2, 316L, 3.1

      Montageproces aansluiting G1-1 / 2. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Gebruik: PMC71, PMP71, PMP75, FMB50/51/52, FMB70, PMC51, PMP51, PMP55.

    • Order code 71389241

      Weld-in adapter G1/2, 316L, A DIN 3852

      Lasadapter voor G1/2 A DIN 3852. Materiaal: 316L. Gebruik: PMP21, PMP51, PMP71.

    • Order code 71389243

      Weld-in adapter G1/2,316L, 3.1,A DIN3852

      Lasadapter voor G1/2 A DIN 3852. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Gebruik: PMP21, PMP51, PMP71.

    • Order code 71304770

      Mountingset, housing T14, special

      Materiaal: 316L. Gebruik: montagekit aan de eigen montagebeugel te hechten/bescherming tegen weersinvloeden. dekking, PMC71, PMP71 / PMP75, FMB70.

    • Order code 71372498

      Mounting bracket 2 valve,stainless steel

      Bevestigingsset Manifold. Materiaal: 316L. Bestaat uit: 1x montagebeugel. 1x U-bouten. 2x Washers A 8.4. 2x Zeshoekmoeren M8. Gebruik: montage van wand / pijp 2", DA63M, PMC51, PMC71, PMP51, PMP71.

    • Order code 71007843

      ToF Adapter FXA291

      Gebruik: aansluiting Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, Commubox FXA291.

    • Order code 71000221

      Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60

      Verbinding RS232(52013675)/ ToF adapter FXA291 (71007843). Gebruik: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.