Proline Prowirl C 200
Vortex flowmeter
Sensor enabling primary element corrosion inspection. Only available for North America
Prowirl C 200 is a product line of carbon steel vortex meters dedicated to the Canadian and American market. The carbon steel sensor offers higher resistance to inter-granular stress corrosion cracking, especially in steam systems for SAGD applications. Prowirl C 200 is only available with cCSAus hazardous area approvals. It is NOT available with CE mark, AD2000 or PED. It is available as compact or remote device version.
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
Dit product is niet verkrijgbaar in deze markt.
-
Overzicht specificaties
-
Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 % -
Measuring range
Liquid: 0.99 to 545 m³/h (0.58 to 321 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 13.8 to 7262 m³/h (8.12 to 4274 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air
with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) -
Medium temperature range
–40 to +400 °C (–40 to +752 °F)
-
Max. process pressure
Class 900
-
Wetted materials
Measuring tube: SA‐106 grade B/SA‐333 grade 6
Bluff body, inspection ports: SA‐105/SA‐350 LF2
DSC sensor: UNS N07718 similar to Alloy 718, 2.4668
Connection: SA‐105/SA‐350 LF2
-
Snelle selectie
Individuele configuratie
-
Voordelen
Compliance to AER – enables customer to fulfill inspection requirements
Higher process control – unique inspection concept allows visual assessment of primary element
High process safety - resistant to intergranular stress corrosion cracking
Convenient...
-
Toepassingsgebied
For steam applications with high chloride content (SAGD) aligned with AER Directive 017 Guidelines.
Device properties
Sensor made of carbon steel
Material for low medium temperatures
Display module with data transfer function
Robust two-chamber housing
...
Documenten / handleidingen / software
-
Proline Prowirl C 200
Technical Information
Sensor enabling primary element corrosion inspection, available as
compact or remote device versionTechnische informatie (TI) -
Proline Prowirl C 200
PROFIBUS PA
Operating Instructions
Vortex flowmeter
Inbedrijfsstellingsvoorschriften (BA) -
Proline Prowirl C 200
HART
Operating Instructions
Vortex flowmeter
Inbedrijfsstellingsvoorschriften (BA) -
Proline Prowirl C 200
FOUNDATION Fieldbus
Operating Instructions
Vortex flowmeter
Inbedrijfsstellingsvoorschriften (BA) -
Proline Prowirl 200
PROFIBUS PA
Description of Device Parameters
Vortex flowmeter
Device Parameter (GP) -
Proline Prowirl 200
FOUNDATION Fieldbus
Description of Device Parameters
Vortex flowmeter
Device Parameter (GP) -
Proline Prowirl 200
HART
Description of Device Parameters
Vortex flowmeter
Device Parameter (GP) -
Proline Prowirl C 200
Brief Operating Instructions
Vortex flowmeter
Short Instruction (KA)10/14Engels -
Replacing the electronics module
Installation Instructions
Prowirl 200
Montage-instructies (EA) -
Transmitter electronics FHX50
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Montage-instructies (EA) -
Replacing the I/O-Module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200
Montage-instructies (EA) -
Inspection Ports
Installation Instructions
Prowirl 200
Montage-instructies (EA) -
Installing sensor parts
Installation Instructions
Prosonic Flow 92F, Prowirl 72, 73, Prowirl 200
Montage-instructies (EA) -
Sealing set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Montage-instructies (EA) -
Set housing security clamp
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Montage-instructies (EA) -
Replacing the connection board, pre amplifier, cable harness
Installation Instructions
Prowirl 200
Montage-instructies (EA) -
I/O module
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Montage-instructies (EA) -
Housing filter
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Montage-instructies (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Montage-instructies (EA) -
Replacing the cover, O-ring cover and the housing seal
Installation Instructions
Prowirl 200 Remote Version
Montage-instructies (EA) -
Cover
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Montage-instructies (EA) -
Replacing the display module
Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50Montage-instructies (EA) -
Replacing the transmitter
Installation Instructions
Prowirl 200
Montage-instructies (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Montage-instructies (EA) -
Replacing the DSC-Sensor and the S-DAT
Installation Instructions
Prowirl 200
Montage-instructies (EA) -
Proline Prowirl 200
Cl. I, II, III Div. 1, Zone 0 for IS
(Ex i Intrinsically safe version)
Safety Instructions
Documentation for hazardous area
Ex Veiligheidsinstructies (XA) -
Proline Prowirl 200
Cl. I, II, III Div. 1, Zone 1 for XP
(Ex d Flameproofed version)
Safety Instructions
Documentation for hazardous area
Ex Veiligheidsinstructies (XA) -
Levelflex FMP5x, Micropilot FMR5x
Weather protection cover
Speciale Documentatie (SD) -
Proline Prowirl 200
Information on the Pressure Equipment Directive
Special documentation
Vortex flowmeter
Speciale Documentatie (SD) -
Proline Prowirl C 200
Procedure for AER Directive 017 Measurement Requirements for Oil and
Gas
Operations
Special documentation
Vortex flow measuring device
Speciale Documentatie (SD) -
Proline Prowirl 200
Functional Safety Manual
Special Documentation
Vortex flowmeter
Speciale Documentatie (SD) -
Change of Directives
Special Documentation
Change of Directives
Speciale Documentatie (SD) -
Proline Prowirl 200
Natural Gas application package
Special Documentation
Vortex flowmeter
Natural Gas application packageSpeciale Documentatie (SD) -
Proline Prowirl 200
Heartbeat Technology Application Package
Special documentation
Vortex flowmeter
Speciale Documentatie (SD) -
Proline Prowirl 200
Air + Industrial Gases application package
Special Documentation
Vortex flowmeter
Air + Industrial Gases application packageSpeciale Documentatie (SD) -
Proline Prowirl 200
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Prowirl 200 HART: 1.02.00Fabrikanten Informatie (MI) -
Proline Prowirl 200
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Prowirl 200 HART: 1.01.01Fabrikanten Informatie (MI) -
Proline Prowirl 200
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Prowirl 200 PROFIBUS PA: 1.01.01Fabrikanten Informatie (MI) -
Proline Prowirl 200
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Prowirl 200 FF : 1.01.00Fabrikanten Informatie (MI) -
GSD Single, GSD_PA_FL_Prowirl200_0x1564_0x02_0x01, 10.04.2015 (Flow, Prowirl 200)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Prowirl200_0x1138_0x04_0x01, 23.11.2018 (Flow, Prowirl 200, 0x1138)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0
Delta V Version: 12.3, 13.3Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, EDD_FF_FL_Prowirl200_0x1038_0x01_0x02, 20.10.2016 (Flow, Prow
irl 200, 0x1038)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Prowirl200_0x1138_0x04_0x01, 10.06.2020 (Flow, Prowirl 200, 0x1138)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Prowirl200_0x0038_0x02_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Prowirl200_0x0038_0x03_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Prowirl200_0x0038_0x03_0x02, 22.03.2018 (Flow, Prowirl 200, 0x0038)
HART,
PDM Version: 8.2.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Prowirl200_0x0038_0x01_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Prowirl200_0x1564_0x02_0x01, 10.04.2015 (Flow, Prowirl 200)
PROFIBUS PA,
PDM Version: 6.1, 8.2, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Prowirl200_0x0038_0x03_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Prowirl200_0x0038_0x02_0x01, 10.06.2014 (Flow, Prowirl 200, 0x0038)
HART,
PDM Version: 6.1, 8.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Prowirl200_0x1038_0x02_0x01, 12.11.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_FF_FL_Prowirl200_0x1038_0x01_0x01, 22.01.2015 (Flow, Prow
irl 200, 0x1038)
FOUNDATION Fieldbus H1,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS14_FF_FL_Prowirl200_0x1038_0x02_0x01, 27.08.2019 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Prowirl200_0x0038_0x03_0x01, 17.08.2015 (Flow, Prowirl 200, 0x0038)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Prowirl200_0x1138_0x04_0x01, 16.01.2018 (Flow, Prowirl 200, 0x1138)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Prowirl200_0x1038_0x02_0x01, 12.11.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Prowirl200_0x1038_0x02_0x01, 28.05.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Prowirl200_0x1038_0x02_0x01, 12.11.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 12.0, 12.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Prowirl200_0x0038_0x02_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Prowirl200_0x1138_0x04_0x01, 23.01.2018 (Flow, Prowirl 200, 0x1138)
HART,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Prowirl200_0x1038_0x02_0x01, 12.11.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS_FF_FL_Prowirl200_0x1038_0x01_0x02, 24.10.2016 (Flow, Prow
irl 200, 0x1038)
FOUNDATION Fieldbus H1,
AMS Version: 10.5, 11.5, 12.5, 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Prowirl200_0x0038_0x01_0x01, 21.08.2019 (Flow, Prowirl 200, 0x0038)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Prowirl200_7x2B_HART_FW1_02_zz_Dev_Rev_3, 27.10.2020 (Flow, Prowirl 200, 0x0038)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.8.0.431Language neutral -
DTM Single, Prowirl200_7x2B_FF_FW1_00_zz_Dev_Rev_1, 22.10.2020 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.6.0.72Language neutral -
DTM Single, Prowirl200_7x2B_HART_FW1_01_zz_Dev_Rev_2, 27.10.2020 (Flow, Prowirl 200, 0x0038)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.2.0.364Language neutral -
DTM Single, Prowirl200_7x2B_7x2C_HART_FW1_03_zz_Dev_Rev_04, 27.10.2020 (Flow, Prowirl 200, 0x0038)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.12.0.537Language neutral -
DTM Single, Prowirl200_7x2B_7x2C_FF_FW1_01_zz_Dev_Rev_2, 22.10.2020 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.11.0.174Language neutral -
DTM Single, Prowirl200_7x2B_7x2C_PA_FW1_01_zz_Dev_Rev_2, 21.10.2020 (Flow, Prowirl 200, 0x1564)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.11.0.135Language neutral -
DTM Single, Prowirl200_7x2Bxx_PA_FW1_00_zz_Dev_Rev_1, 21.10.2020 (Flow, Prowirl 200, 0x1564)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.1.0.94Language neutral -
DTM Single, Prowirl200_7x2Bxx_HART_FW1_00_zz_Dev_Rev_1, 23.10.2020 (Flow, Prowirl 200, 0x0038)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.0.0.281Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Flow_1_05_00, 22.07.2015 (Flow)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.12Faceplate1.05.00Language neutral -
Faceplate Single, PRM_HART_FL_Prowirl200_0x0038_0x02_0x01, 10.06.2014 (Flow, Prowirl 200, 0x0038)
HART,
Plant Resource Manager Version: R3.11Faceplate1.01.01Language neutral -
Faceplate Single, PRM_FF_FL_Prowirl200_0x1038_0x01_0x01, 22.01.2015 (Flow
, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Prowirl200_0x1138_0x04_0x01, 16.01.2018 (Flow, Prowirl 200, 0x1138)
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Prowirl200_0x0038_0x03_0x01, 02.06.2015 (Flow, Prowirl 200, 0x0038)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_FL_Prowirl200_0x1038_0x02_0x01, 28.05.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Note Single, Release_Notes_Prowirl200_FF_0x1038_0x01, 23.08.2018 (Flow, Prowirl 200, 0x1038)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 15.05.2020 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 15.05.2020 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Prowirl C, Prowirl F, Prowirl O, Prowirl R, Prowirl D
Productcode: 7C2B-, 7O2B-, 7F2B-, 7R2B-, 7D2B-
Regio: India
Keuringsinstantie: CC(O)E
Catagorie: zone 0,1
Bescherming: Ex iaExplosion ProtectionEngels -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Productcode: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: International (IECEx)
Keuringsinstantie: DEKRA
Bescherming: Ex ic, Ex ic [ia Ga], Ex ic [ia], Ex nA, Ex nA [ia Ga]Explosion ProtectionEngels -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Productcode: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: International (IECEx)
Keuringsinstantie: DEKRA
Bescherming: Ex ia, Ex tbExplosion ProtectionEngels -
Prowirl R, Prowirl O, Prowirl F, Prowirl D, Prowirl C, Prosonic Flow B, Promass F, Promass E, Promass A, Promag P, Promag H, Promag E
Productcode: O9B2B-, O5P2B-, O5H2B-, 9B2B-, 8F2B-, 8E2C-, 8E2B-, 8A2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 5P2B-, 5H2B-, 5E2B-
Regio: India
Keuringsinstantie: CC(O)E
Catagorie: zone 1Explosion ProtectionEngels -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Productcode: 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: South Korea
Keuringsinstantie: KTL
Catagorie: zone 1, zone 21
Bescherming: Ex ia, Ex tbExplosion Protection -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Productcode: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: Europe (ATEX)
Keuringsinstantie: DEKRA
Catagorie: II 3 G, II 1/3 G
Bescherming: Ex ic [ia Ga], Ex ic [ia], Ex nAExplosion ProtectionEngels -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Productcode: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: Europe (ATEX)
Keuringsinstantie: DEKRA
Catagorie: II 2 D, II 2 G, II 1/2 G, II 1 G, II 2(1) D
Bescherming: Ex ia, Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEngels -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Productcode: 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: South Korea
Keuringsinstantie: KTL
Catagorie: zone 1, zone 21
Bescherming: Ex d [ia], Ex tbExplosion Protection -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-, O7C2B-, O7D2B-, O7F2B-, O7O2B-, O7R2B-, 7D2C-, 7F2C-, 7O2C-, 7R2C-
Regio: Canada, USA
Keuringsinstantie: CSA
Catagorie: I/2/A,B,C,D/T6...T1, II,III/1/E,F,G/
Bescherming: DIP, NIExplosion ProtectionEngels -
Prowirl C, Prowirl F, Prowirl O, Prowirl R, Prowirl D
Productcode: 7C2B-, 7O2B-, 7F2B-, 7R2B-, 7D2B-
Regio: India
Keuringsinstantie: CC(O)E
Catagorie: zone 1
Bescherming: Ex iaExplosion ProtectionEngels -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Productcode: 7F2C-, 7O2C-, 7R2C-, 7D2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-, O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-
Regio: China
Keuringsinstantie: NEPSI
Catagorie: zone 2
Bescherming: Ex ic, Ex nAExplosion ProtectionEngels -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Productcode: 7F2C-, 7R2C-, 7D2C-, 7O2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: Japan
Keuringsinstantie: CML
Bescherming: Ex d [ia]Explosion ProtectionJapans -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-
Regio: South Africa
Keuringsinstantie: MTEx
Catagorie: zone 2, zone 0,2
Bescherming: Ex ic, Ex ic [ia Ga], Ex ic [ia], Ex nA, Ex nA [ia Ga], Ex ecExplosion ProtectionEngels -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Productcode: 7F2C-, 7O2C-, 7R2C-, 7D2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-, O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-
Regio: China
Keuringsinstantie: NEPSI
Catagorie: zone 1
Bescherming: Ex d [ia], Ex ia, Ex d [ia Ga]Explosion ProtectionEngels -
Promag E, Promag H, Promag P, Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: O7R2C-, O7F2C-, O7D2C-, O5P2B-, O5H2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 5P2B-, 5E2B-
Regio:
Keuringsinstantie:
Bescherming: Ex ia, Ex ic, Ex nA, Ex tb, Ex ec, Ex dbExplosion ProtectionEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-
Regio: South Africa
Keuringsinstantie: SABS
Catagorie: zone 1, zone 2, zone 0, zone 21Explosion ProtectionEngels -
Prowirl F, Prowirl O, Prowirl R, Prowirl D, Prowirl C
Productcode: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: International (IECEx)
Keuringsinstantie: DEKRA
Bescherming: Ex d [ia], Ex tb, Ex tb [ia Da]Explosion ProtectionEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-
Regio: South Africa
Keuringsinstantie: MTEx
Catagorie: zone 1, zone 0, zone 21, zone 0,1
Bescherming: Ex ia, Ex tb, Ex tb [ia Da]Explosion ProtectionEngels -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Productcode: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: Brazil
Keuringsinstantie: TÜV
Catagorie: zone 2
Bescherming: Ex nAExplosion ProtectionPortugees -
Prowirl C, Prowirl F, Prowirl O, Prowirl R, Prowirl D
Productcode: 7C2B-, 7O2B-, 7F2B-, 7R2B-, 7D2B-
Regio: India
Keuringsinstantie: CC(O)E
Catagorie: zone 0
Bescherming: Ex iaExplosion ProtectionEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-
Regio: India
Keuringsinstantie: CC(O)E
Catagorie: zone 1Explosion ProtectionEngels -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Productcode: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-, O7C2B-, O7D2B-, O7F2B-, O7O2B-, O7R2B-
Regio: China
Keuringsinstantie: NEPSI
Catagorie: zone 1, zone 0, zone 20,21
Bescherming: Ex iaD 20/21 Txxx°C, Ex d [ia], Ex ia, Ex d [ia Ga]Explosion ProtectionEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-, 7R2C-, 7R2B-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 7O2C-
Regio: China
Keuringsinstantie: NEPSI
Catagorie: zone 0,1
Bescherming: Ex ia IIC T6...T1 Ga/Gb, Ex d [ia] IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 Gb, Ex iaD 20/21 Txxx°CExplosion ProtectionEngels -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Productcode: 7F2C-, 7O2C-, 7D2C-, 7R2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: Europe (ATEX)
Keuringsinstantie: DEKRA
Catagorie: II 2 D, II 2 G, II 1/2 G, II 2(1) D
Bescherming: Ex d [ia], Ex ia, Ex tbExplosion ProtectionEngels -
Prowirl D, Prowirl F, Prowirl O, Prowirl R, Prowirl C
Productcode: 7F2C-, 7R2C-, 7O2C-, 7D2C-, 7F2B-, 7R2B-, 7D2B-, 7O2B-, 7C2B-
Regio: Brazil
Keuringsinstantie: TÜV
Catagorie: zone 0, zone 0,1
Bescherming: Ex iaExplosion ProtectionPortugees -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-
Regio: China
Keuringsinstantie: NEPSI
Catagorie: zone 2
Bescherming: Ex ic [ia Ga] IIC T6...T1 Gc, Ex nA IIC T6...T1 Gc, Ex nA [ia Ga] IIC T6...T1 Gc, Ex ic IIC T6...T1 GcExplosion ProtectionEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: O7R2B-, O7O2B-, O7F2B-, O7D2B-, O7C2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-
Regio: China
Keuringsinstantie: NEPSI
Catagorie: zone 1
Bescherming: Ex d [ia] IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 Gb, Ex ia IIC T6...T1 GbExplosion ProtectionEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-, O7C2B-, O7D2B-, O7F2B-, O7O2B-, O7R2B-, 7D2C-, 7F2C-, 7O2C-, 7R2C-
Regio: Canada, USA
Keuringsinstantie: CSA
Catagorie: I/1/A,B,C,D/T6...T1
Bescherming: DIP, ISExplosion ProtectionEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-, O7C2B-, O7D2B-, O7F2B-, O7O2B-, O7R2B-, 7D2C-, 7F2C-, 7O2C-, 7R2C-
Regio: Canada, USA
Keuringsinstantie: CSA
Catagorie: I/1/A,B,C,D/T6...T1, II,III/1/E,F,G/
Bescherming: DIP, XP/ISExplosion ProtectionEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7C2B-, 7D2B-, 7D2C-, 7F2B-, 7F2C-, 7O2B-, 7O2C-, 7R2B-, 7R2C-
Regio: International
Keuringsinstantie: FieldComm GroupFieldbus ConformanceEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-
Regio: International
Keuringsinstantie: FieldComm Group
Software Version: DEVICE REV. 2, HART 7Fieldbus ConformanceEngels -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Productcode: 7C2B-, 7D2B-, 7F2B-, 7O2B-, 7R2B-
Regio: Kazakhstan
Keuringsinstantie: MEMST
Keurnummer: GOST-12959MetrologyRussisch -
Prowirl C, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Regio:
Heartbeat TechnologyDuits , Engels
Accessoires / Spare parts
-
-
Nr 34 Order code 71108602
I/O module Flow, 2-wr. 2x4-20mA,HART, Ex
Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 34 Order code 71164940
I/O module, 2-wire, PA/FF, PFS, Ex, V2
Niet-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS = schakelen output. Versie 2. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200.
-
-
-
Nr 36 Order code 71222996
Kit pre-amplifier, Prowirl 200
-
-
-
Order code 71128617
Overvoltage protection (OVP10),1-Channel
4-20mA HART. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71128619
Overvoltage protection (OVP20),2-Channel
4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71197334
Transmitter electronics FHX50
Bestaat uit: Elektronica, lint kabel. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200, Prosonic Flow 200.
-
Order code
Remote display FHX50 please order with separate order structure.
-
Order code 71296840
Plug M12, VA
To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.
-
-
-
Nr 30 Order code XPD0011-
-
-
-
Order code 71206552
-
Order code 71206554
-
Order code 71206555
-
-
-
Nr 34 Order code XPD0015-
I/O module, 2-wire, 4-20mA, HART, Ex
Non-Ex, Ex. 1x current output HART.
-
-
-
Order code 71206556
-
-
-
Nr 46 Order code 71222998
Kit cable harness, PW200, compact,remote
-
-
-
Nr 34 Order code XPD0016-
I/O module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.
-
-
-
Nr 46 Order code 71222998
Kit cable harness, PW200, compact,remote
-
-
-
Nr 34 Order code XPD0018-
I/O,2-wire,4-20mA,HART,PFS,4-20mA input
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input.
-
-
-
Nr 43 Order code 71223001
-
-
-
Nr 44 Order code 71223003
-
-
-
Nr 37 Order code 71110280
Klemmenset 2-dr. , I/O Module
Consists of: 4x Terminal 2 pole, groen. Gebruik: FMP50/51/52/53/54/55/56/57. Gebruik: Promass TB2.
-
-
-
Nr 40 Order code XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.
-
Nr 40 Order code XPD0025-
Display module, SD03, Touch Control
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.
-
-
-
Nr 20 Order code 71110299
Cover GT20 Alu, HNBR
Materiaal: aluminium, gecoat. O-ring EPDM, PTFE gecoat. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/ 51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 20 Order code 71110297
Deksel GT20 Aluminium, met glasvenster,
Materiaal: aluminium, gecoat O-ring EPDM, PTFE gecoat. Gebruik: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110301
Cover GT20 Alu, Terminal Ex, gasket
Materiaal: aluminium, gecoat. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71110302
Cover GT20 Alu, Terminal Ex d, gasket
Materiaal: aluminium, gecoat. O-ring EPDM, PTFE-gecoate. FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71185517
Cover GT20 Alu, Terminal, OVP, gasket
Materiaal: aluminium. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, voor overspanningsbeveiliging, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 24 Order code 71223005
Kit cover, Alu, remote, sensor
Gebruik: Prowirl 200. Bestaat uit: 1x afdekking Alu, 1x O-ring 75,87 x2,62 NBR coating.
-
Nr 24 Order code 71223006
Kit cover,Alu,remote,sensor, -50°C/-58°F
Gebruik: Prowirl 200. Bestaat uit: 1x deksel Alu, 1x O-ring 75,87 x2,62 FVMQ gecoat.
-
-
-
Nr 65 Order code 71110303
Sealing set housing GT18,GT19,GT20
Bestaat uit: O-ring 88.5x3.53 EPDM/PTFE, bedekken elektronica compartiment, behuizing GT19. O-Ring 88.5x3.53 NBR, bedekken elektronica compartiment, huisvesting GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, bedekken aansluitruimte, behuizing GT19. O-Ring 91.67x3.53 NBR, bedekken aansluitruimte, huisvesting GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, behuizing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 73 Order code 71223053
Kit gaskets housing, remote, sensor
Gebruik: Prowirl 200. Bestaat uit: 1x O-ring 75,87x2,62 NBR coating als dekking. 1x O-ring 50,39x3,53 HNBR gecoate voor behuizing / behuizing te ondersteunen.
-
Nr 73 Order code 71223054
Kit gaskets housing,remote,sensor, -50°C
Gebruik: Prowirl 200,-50°C/-58°F. Bestaat uit: 1x O-Ring 75.87x2.62 FVMQ als dekking. 1x O-ring 50,39 x3,53 FVMQ voor behuizing/ behuizing te ondersteunen.
-
-
-
Nr 19 Order code 71115175
Housing filter Brass/Ni GT19/20, 1 set
Bestaat uit: 2x filterplug messing nikkel. Drukcompensatie filter. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 17 Order code 71115176
Set behuizing borgklemmen
Behuizing GT18/GT19/GT20 Gebruik: Promass TB2.
-
-
-
Nr 61 Order code 71223056
-
Nr 61 Order code 71223058
Kit cable, PW200, remote, 10m, bk, M12
lengte = 10m/30ft met stekker M12
-
Nr 61 Order code 71223060
Kit cable, PW200, remote, 20m, bk, M12
lengte = 20m/70ft met stekker M12
-
Nr 61 Order code 71223062
Kit cable, PW200, remote, 30m, bk, M12
lengte = 30m/90ft met stekker M12
-
Nr 61 Order code 71223063
-
Nr 61 Order code 71223064
-
Nr 61 Order code 71223065
-
Nr 61 Order code 71223067
-
Nr 61 Order code 71223068
-
Nr 61 Order code 71223069
-
Nr 61 Order code 71223070
-
Nr 61 Order code 71223071
-
Nr 61 Order code 71223063
-
Nr 61 Order code 71223064
-
Nr 61 Order code 71223065
-
Nr 61 Order code 71223067
-
Nr 61 Order code 71223068
-
Nr 61 Order code 71223069
-
Nr 61 Order code 71223070
-
Nr 61 Order code 71223071
-
Nr 61 Order code 71223073
-
Nr 61 Order code 71223074
-
Nr 61 Order code 71223075
-
-
-
Order code 71162242
Weather prot. cover GT18/GT19/GT20, 316L
Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 69 Order code 71223000
Kit assembly parts inspection port,PW200
Usage: Prowirl 200 with sensor C. Consists of: 2x inspection gasket Sigraflex HP, 2x inspection cover 3.1, 8x screw 5/16x7/8 hexagon socket, 2x Inspection centering sleeve.
-
-
-
Order code 7X2BXX-
-