iTEMP TMT82
Temperature transmitter

iTEMP TMT82
Temperature transmitter ©Endress+Hauser
Product picture iTEMP TMT82
Temperature transmitter ©Endress+Hauser
Temperature transmitter ©Endress+Hauser
iTEMP TMT82
Temperature transmitter ©Endress+Hauser

Transformation of sensor signals into stable and standardized output signals for all industries

Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers converted signals from resistance thermometers (RTD) and thermocouples (TC), but also resistance and voltage signals using HART® communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.

  • Voordelen

    • Certified up to SIL 2/3 - hardware/software - according to IEC 61508:2010

    • Safe operation in hazardous areas, international approvals such as FM IS, NI; CSA IS, NI; ATEX, NEPSI, IECEx Ex ia, Ex nA for intrinsically safe installation in zone 1 and zone 2;

      ...

  • Toepassingsgebied

    • The device stands out due to signal reliability, long-term stability, high precision and advanced diagnostics (important in critical processes)

    • For the highest level of safety, availability and risk reduction

    • Universal input for RTD, TC, resistance...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Head transmitter

  • Input

    2 x RTD, TC

  • Output

    1 x analog 4...20 mA / HART

  • Auxiliary power supply

    11...42 V DC

  • Communication

    HART-protocol

  • Installation

    Terminal head form B or DIN-Rail housing

  • Accuracy

    (Pt100) <= 0,1K (digital) + 0,03% (set range)

  • Galvanic isolation

    yes

  • Certification

    ATEX II1G Ex ia IIC T4/T5/T6

    ATEX II2D Ex tb IIIC Db

    ATEX II3D Ex tc IIIC Dc

    ATEX II3G Ex nA IIC T6

    ATEX II1G Ex ia IIC T6, II3D

    ATEX II3G Ex nA IIC T6, II3D

    ATEX II2G Ex d T6, II2D Ex tb IIIC

    CSA IS, NI I / 1+2/A-D

    CSA XP, NI, DIP I, II, III/1+2/A-G

    FM IS,NI I / 1+2/A-D

    FM XP, NI, DIP I, II, III/1+2/A-G

    IECEx Ex ia IIC T4/T5/T6

    IECEx Ex tb IIIC Db

    IECEx Ex d T6 Gb, Ex tb IIIC Db

    NEPSI Ex ia IIC T4/T5/T6

    NEPSI Ex nAL II T4/T5/T6

    ATEX IECEx II1G Ex ia IIC T6 Ga

    FM+CSA IS, NI I/1+2/A-D

    EAC

    Marine approval

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
    • Order code

      The unit is not repairable

    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (europees)

      2x schroef, 2x veer, 2x springveer, 1x afdichting CDI-connector

    • Order code 71044062

      Fixing kit cpl.TMT82/84/85 USA(american)

      2x screws, 1x sealing CDI-connector

    • Order code 71123339

      Set mounting bracket wall cpl. W06

    • Order code 71123342

      Set mounting bracket pipe housing W06

    • Order code 71409760

      Spare parts kit DIN rail terminal plug

      TMT82

    • Order code 71086650

      TID10 servicekabel

      Extension cable for the CDI-interface for remote operation of the TID10 display for service and maintenance work Length: 40cm.

    • Order code 51000856

      DIN rail montageclip voor koptransmitter

      Geschikt voor de montage van een temperatuur koptransmitter op DIN rail.

    • Order code DIENST-
    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.

    • Order code FXA195-

      Commubox FXA195 (USB)

      USB HART interface ten behoeve van universele configuratie tools (b.v. FieldCare) De stroomuitgang (4..20mA) is intrinsiek veilig uitgevoerd (SIL2, IEC61508) De interface wordt via de bijgeleverde kabel aan een PC of laptop aangesloten. De interface wordt gevoed via USB

    • Order code TID10-

      Display voor koptransmitter TID10