Omnigrad S TC88
Modular thermometer

Product picture of TC thermometer TC88 ©Endress+Hauser
Product picture of TC thermometer TC88 in application

Comprehensive and common temperature measurement technology for almost all branches of industry

The high modular and robust thermometer finds its use in several applications in almost all industries, and is perfectly suited for use in the Chemical and Food & Beverages industry. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.

  • Voordelen

    • High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths

    • Variable total length in suitable thermowells thanks to compression fitting on extension neck

    • Types of protection...

  • Toepassingsgebied

    • Universal range of application

    • Suitable for installation in already existing thermowells

    • Measuring range: –40 to 1100 °C (–40 to 2012 °F)

    • Degree of protection up to IP68

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Thermocouple

  • Characteristic / Application

    metric style

    modular temperature assembly

    universal range of application

    suitable for hazardous areas

    suitable for high process pressures

    threaded process connection

    with neck

    to use with thermowell

  • Terminal head

    TA20A - aluminium - cover with screws

    TA20B - plastics - screw cover

    TA20D - aluminium - hinged cover high

    TA20J - SS - deep-drawn w. or w/o. display

    TA20R - SS - machined w. screw cover

    TA20W - aluminium - cover w. snap fit

    TA21E - aluminium - screw cover w. chain

    TA30A - E+H, aluminium - cover low - w. or w/o. display

    TA30D - E+H, aluminium - cover high

  • Thermowell / protection tube

    to use with thermowell

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    Insert Diameter

    3,0 mm (0,12'')

    6,0 mm (0,24'')

  • Max. immersion length on request

    up to 30.000,00 mm (1.181,10'')

  • Material protection tube/ thermowell

    1.4404 (316L)

    1.4571 (316Ti)

    Alloy 600

  • Optional coating

    Not defined

  • Process connection

    male thread:

    G1/2"

    NPT1/2"

    M14x1.5

    M18x1.5

  • Tip shape

    straight

  • Surface roughness Ra

    0,8 μm (31,5 μin.)

  • Operating temperature range

    Type K:

    -40 °C ...1.100 °C

    (-40 °F ...2.012 °F)

    Type J:

    -40 °C ...750 °C

    (-40 °F ...1.382 °F)

  • Max. process pressure (static)

    at 20 °C: 500 bar (7.252 psi)

  • Accuracy

    class 1 acc. to IEC 60584

  • Response time

    depending on configuration

    t50 = 1 s

    t90 = 2 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II

    NEPSI

    IECEx

    NEPSI

    EAC Ex

  • Certification

    Gost Metrology

    SIL (transmitter only)

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • C
  • A
    • Nr A Order code TPC100-

      Meetinzet TPC100

      Thermokoppel meetinzet, diam. 3 of 6mm, isolatie MgO, RVS mantel. Opbouw conform EN 60584, DIN 43735, ANSI MC96.1. Warme las geïsoleerd of geaard. Meetbereik type J: -40...750°C Meetbereik type K: -40...1100°C

  • E
  • D
    • Nr D Order code TA20A-

      Aansluitkop TA20A

      Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. +100 oC; ATEX: +95 oC. Beperkte productbeschikbaarheid, vervanger is TA30A.

    • Nr D Order code TA20B-

      Aansluitkop TA20B

      "Product being phased out, limited availability." Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material:Polyamid black. Ambient temperature: max. +80 oC. Protection: IP65.

    • Nr D Order code TA20D-

      Aansluitkop TA20D

      Product being phased out, limited availability. Connection head to mount a measuring insert with up to two head transmitters or a connection socket and one head transmitter. For mounting on armature or protection sleeve. Material: Aluminium, varnished Ambient temperature: max. +100 oC; ATEX: +95 oC. Protection: IP66 Beperkte productbeschikbaarheid tot 2017, vervanger is TA30D.

    • Nr D Order code TA20W-

      Aansluitkop TA20W

      Bolvormig met deksel scharnierend uitge- voerd. Materiaal: aluminium Max. omgevingstemperatuur: 100°C Beschermingsklasse: IP66

    • Nr D Order code TA21E-

      Aansluitkop TA21E

      Aansluitkop voor temperatuursensor. Materiaal: aluminium Omgevingstemperatuur : 100°C Beschermingsklasse : IP65

  • F
    • Nr F Order code TA50-

      Knelfitting TA50

      Schroef in. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

  • B
    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      PROFIBUS PA temperatuur transmitter voor kop- of veldmontage met dubbele sensoringang en advanced diagnostics voor sensorbewaking. Profibus PA Profile 3.02. Galvanische isolatie 2kV. Stroomverbruik: 11 mA. Montage: aansluitkop vorm B, DIN EN50446. Standaard fabrieksinstelling: Kanaal 1: Pt100, 3-draads, oC. kanaal 2: inactief. Meerdere configuraties selecteerbaar.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      FOUNDATION Fieldbus temperatuur transmitter voor kop- of veldmontage met dubbele sensoringang en advanced diagnostics voor sensorbewaking. Galvanische isolatie 2 kV Meetsignaal: RTD, TC, Ohm, mV. Stroomverbruik: 11 mA.

    • Order code TID10-

      Display voor koptransmitter TID10

      Opsteek display voor koptransmitters. Dot-matrix met weergave gemeten waarde. 12 DIP-switches aan onderzijde. Instellingen: FF: Simulatie, write Lock. PA: Bus adres, write Lock. Geschikt voor: TMT85, TMT84 en TMT82

    • Order code READWIN-

      ReadWin2000 configuratie/uitleessoftware

      ReadWin2000 configuratie software

    • Order code TXU10-

      Configuratiekit TXU10

      Set-up software incl. USB- interfacekabel. Dit betreft een product uit het E-direct portfolio waar staffelprijzen aan gekoppeld zijn. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code FXA195-

      Commubox FXA195 (USB)

      USB HART interface ten behoeve van universele configuratie tools (b.v. FieldCare) De stroomuitgang (4..20mA) is intrinsiek veilig uitgevoerd (SIL2, IEC61508) De interface wordt via de bijgeleverde kabel aan een PC of laptop aangesloten. De interface wordt gevoed via USB

  • D
    • Nr D Order code TA30A-

      Aansluitkop TA30A

      Aansluitkop voor aansluitblok of koptransmitter + optioneel display. Deksel: laag, scharnierend, optioneel met venster. Materiaal: aluminium Coating: polyester poeder-coating. Kleur: huis blauw, deksel grijs. Omgevingstemperatuur.: -50...150 oC. Beschermingsklasse: IP66/68, NEMA 4X.

    • Nr D Order code TA30D-

      Aansluitkop TA30D

      Aansluitkop voor 2 koptransmitters of aansluitblok. Deksel: hoog, scharnierend. Materiaal: aluminium Coating: polyester poeder-coating. Kleur: huis blauw, deksel grijs. Omgevingstemperatuur: -50...150 oC Beschermingsklasse: IP66/68, NEMA 4X.

    • Nr D Order code TA30P-

      Aansluitkop TA30P

      Aansluitkop voor 2 transmitters of aansluitblokken. Deksel: hoog, scharnierend Materiaal: polyamide PA12 antistatisch. Kleur: zwart. Omgevingstemp.:-40...120°C (behuizing). Bescherming: IP65 (behuizing).

  • B
    • Nr B Order code TMT181-

      iTEMP TMT181, koptransmitter PCP

      Temperatuur transmitter, PC- programmeerbaar. Toepassing: RTD, TC, TC, Ohm, mV. 2-draads 4-20mA, galvanische isolatie. Foutreactie: NAMUR NE 43. Montage: kopvorm B, DIN EN50446. UL vermeld.

    • Nr B Order code TMT182-

      iTEMP TMT182, koptransmitter HART

      Temperatuurtransmitter, Protocol HART. Toepassing: RTD, TC, TC, Ohm, mV. 2-draads 4-20mA, SIL2, galvanische isolatie. Foutreactie: NAAM NE 43. Montage: kopvorm B, DIN EN50446. UL vermeld.

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-draads temperatuurtransmitter. Dubbele universele sensoringang. Galvanische scheiding 2 kV (input/ output). Toepassing: RTD, TC, Ohm en mV. :: Zeer betrouwbaar door drift detectie en sensor back-up. :: Optioneel ook voor veiligheidskritieke applicaties door middel van SIL 2/3 acc. naar IEC61508