Omnigrad M TR13
Modular RTD thermometer

Omnigrad M TR13
Modular RTD thermometer ©Endress+Hauser
Omnigrad M TR13
Modular RTD thermometer ©Endress+Hauser
Omnigrad M TR13
Modular RTD thermometer ©Endress+Hauser

Comprehensive and common temperature measurement technology for almost all branches of industry

The high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.

  • Voordelen

    • High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths

    • High degree of insert compatibility and design as per DIN 43772

    • Extension neck to protect the head transmitter...

  • Toepassingsgebied

    • Universal range of application

    • Measuring range: -200 to +600 °C (-328 to 1112 °F)

    • Pressure range up to 100 bar (1450 psi)

    • Degree of protection: up to IP68

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    modular temperature assembly

    universal range of application

    suitable for hazardous areas

    flanged process connection

    with neck

    incl. thermowell / protection tube (metal)

    usable with insert StrongSens

  • Terminal head

    TA20A - aluminium - cover with screws

    TA20B - plastics - screw cover

    TA20A - aluminium - cover with screws

    TA20B - plastics - screw cover

    TA20D - aluminium - hinged cover high

    TA20J - SS - deep-drawn w. or w/o. display

    TA20R - SS - machined w. screw cover

    TA20W - aluminium - cover w. snap fit

    TA21E - aluminium - screw cover w. chain

    TA30A - E+H, aluminium - cover low - w. or w/o. display

    TA30D - E+H, aluminium - cover high

  • Thermowell / protection tube

    welded protection tube

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    9,0 mm (0,35'')

    11,0 mm (0,43'')

    12,0 mm (0,47'')

    14,0 mm (0,55")

    15,0 mm (0,59")

  • Max. immersion length on request

    up to 10.000,00 mm (393,70'')

  • Material protection tube/ thermowell

    1.4404 (316L)

    1.4571 (316Ti)

    Alloy C276 (2.4819)

    Alloy 600 (2.4816)

  • Optional coating

    Tantal

    PTFE Teflon

    PVDF

  • Process connection

    flange:

    DN15 PN40 B1 (EN1092)

    DN15 PN40 C (EN1092)

    DN25 PN20 B1 (EN1092)

    DN25 PN40 C (EN1092)

    DN25 PN50 B1 (EN1092)

    DN25 PN100 B2 (EN1092)

    DN40 PN40 B1(EN1092)

    DN50 PN40 B1 (EN1092)

    ASME 1" 150 RF (B16.5)

    ASME 1" 300 RF (B16.5)

  • Tip shape

    straight

    reduced

    tapered

  • Surface roughness Ra

    1,6 μm (63,0 μin.)

  • Operating temperature range

    PT100 TF StrongSens:

    -50 °C ...500 °C

    (-58 °F ...932 °F)

    PT100 WW:

    -200 °C ...600 °C

    (-328 °F ...1.112 °F)

    PT100 TF:

    -50 °C ...400 °C

    (-58 °F ...752 °F)

  • Max. process pressure (static)

    at 20 °C: 50 bar (725 psi)

  • Accuracy

    class A acc. to IEC 60751

    class AA acc. to IEC 60751

  • Response time

    depending on configuration

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II

    ATEX IECEx

    NEPSI

    IECEx

    EAC Ex

  • Certification

    Gost Metrology

    SIL (transmitter only)

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • C
  • A
    • Nr A Order code TPR100-

      Meetinzet TPR100

      Pt100 meetinzet, diam. 3 of 6mm, isolatie MgO, RVS mantel. Geconstrueerd vlgs. DIN EN 60751, DIN 43735. Meetbereik afh. van type meetelement.

    • Nr A Order code TS111-

      Insert iTHERM TS111

      Vervangbaar, metrische versie volgens DIN43735.

  • F
    • Nr F Order code TA730-

      Beschermhuls TA730

      Beschermhuls voor geflensde thermowell volgens DIN Form F. In PTFE, PVDF, titanium en tantaal voor thermowells TW13, TR13 en TC13. PTFE, PVDF bereken formule TL=L+15mm Titanium/tantaal bereken formule TL = L+1mm L = thermowell insteeklengte

  • E
    • Nr E Order code TW13-

      Thermowell TW13

      Thermowell uit pijpmateriaal met nek en geflensde procesaansluiting. Compleet met schroefaansluiting voor aansluitkop. Volgens DIN43772 vormen 2F en 3F.

    • Order code TR88-

      RTD Temperatuursensor TR88

      Pt100 temperatuursensor met DIN-stijl nek en geschroefde (uitw.) aansluiting voor thermowell. De vervangbare MgO geïsoleerde meetinzet met Pt100 is veer- belast om een goed contact met de thermowell te waarborgen. De inzetbereiken zijn -50..+600°C (TF sensor) en -200..+600°C (WW sensor).

  • D
    • Nr D Order code TA20A-

      Aansluitkop TA20A

      Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. +100 oC; ATEX: +95 oC. Beperkte productbeschikbaarheid, vervanger is TA30A.

    • Nr D Order code TA20B-

      Aansluitkop TA20B

      "Product being phased out, limited availability." Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material:Polyamid black. Ambient temperature: max. +80 oC. Protection: IP65.

    • Nr D Order code TA20D-

      Aansluitkop TA20D

      Product being phased out, limited availability. Connection head to mount a measuring insert with up to two head transmitters or a connection socket and one head transmitter. For mounting on armature or protection sleeve. Material: Aluminium, varnished Ambient temperature: max. +100 oC; ATEX: +95 oC. Protection: IP66 Beperkte productbeschikbaarheid tot 2017, vervanger is TA30D.

    • Nr D Order code TA20R-

      Aansluitkop TA20R

      Aansluitkop voor temperatuursensor volgens DIN B, in RVS 316L/1.4404 Maximum temperatuur 100°C Beschermingsklasse IP66/67. Beperkte productbeschikbaarheid, vervanger is TA30R.

    • Nr D Order code TA20W-

      Aansluitkop TA20W

      Bolvormig met deksel scharnierend uitge- voerd. Materiaal: aluminium Max. omgevingstemperatuur: 100°C Beschermingsklasse: IP66

    • Nr D Order code TA21E-

      Aansluitkop TA21E

      Aansluitkop voor temperatuursensor. Materiaal: aluminium Omgevingstemperatuur : 100°C Beschermingsklasse : IP65

  • B
    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      PROFIBUS PA temperatuur transmitter voor kop- of veldmontage met dubbele sensoringang en advanced diagnostics voor sensorbewaking. Profibus PA Profile 3.02. Galvanische isolatie 2kV. Stroomverbruik: 11 mA. Montage: aansluitkop vorm B, DIN EN50446. Standaard fabrieksinstelling: Kanaal 1: Pt100, 3-draads, oC. kanaal 2: inactief. Meerdere configuraties selecteerbaar.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      FOUNDATION Fieldbus temperatuur transmitter voor kop- of veldmontage met dubbele sensoringang en advanced diagnostics voor sensorbewaking. Galvanische isolatie 2 kV Meetsignaal: RTD, TC, Ohm, mV. Stroomverbruik: 11 mA.

    • Nr B Order code TID10-

      Display voor koptransmitter TID10

      Opsteek display voor koptransmitters. Dot-matrix met weergave gemeten waarde. 12 DIP-switches aan onderzijde. Instellingen: FF: Simulatie, write Lock. PA: Bus adres, write Lock. Geschikt voor: TMT85, TMT84 en TMT82

    • Order code READWIN-

      ReadWin2000 configuratie/uitleessoftware

      ReadWin2000 configuratie software

    • Order code TXU10-

      Configuratiekit TXU10

      Set-up software incl. USB- interfacekabel. Dit betreft een product uit het E-direct portfolio waar staffelprijzen aan gekoppeld zijn. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code FXA195-

      Commubox FXA195 (USB)

      USB HART interface ten behoeve van universele configuratie tools (b.v. FieldCare) De stroomuitgang (4..20mA) is intrinsiek veilig uitgevoerd (SIL2, IEC61508) De interface wordt via de bijgeleverde kabel aan een PC of laptop aangesloten. De interface wordt gevoed via USB

  • D
    • Nr D Order code TA30A-

      Aansluitkop TA30A

      Aansluitkop voor aansluitblok of koptransmitter + optioneel display. Deksel: laag, scharnierend, optioneel met venster. Materiaal: aluminium Coating: polyester poeder-coating. Kleur: huis blauw, deksel grijs. Omgevingstemperatuur.: -50...150 oC. Beschermingsklasse: IP66/68, NEMA 4X.

    • Nr D Order code TA30D-

      Aansluitkop TA30D

      Aansluitkop voor 2 koptransmitters of aansluitblok. Deksel: hoog, scharnierend. Materiaal: aluminium Coating: polyester poeder-coating. Kleur: huis blauw, deksel grijs. Omgevingstemperatuur: -50...150 oC Beschermingsklasse: IP66/68, NEMA 4X.

    • Nr D Order code TA30P-

      Aansluitkop TA30P

      Aansluitkop voor 2 transmitters of aansluitblokken. Deksel: hoog, scharnierend Materiaal: polyamide PA12 antistatisch. Kleur: zwart. Omgevingstemp.:-40...120°C (behuizing). Bescherming: IP65 (behuizing).

  • B
    • Nr B Order code TMT180-

      iTemp TMT180, koptransmitter Pt100

      Temperatuur transmitter, PC programmeerbaar. Toepassing: OTO. 2-draads 4-20mA. Foutreactie: NAMUR NE 43. Montage: kopvorm B, DIN EN50446. UL vermeld.

    • Nr B Order code TMT181-

      iTEMP TMT181, koptransmitter PCP

      Temperatuur transmitter, PC- programmeerbaar. Toepassing: RTD, TC, TC, Ohm, mV. 2-draads 4-20mA, galvanische isolatie. Foutreactie: NAMUR NE 43. Montage: kopvorm B, DIN EN50446. UL vermeld.

    • Nr B Order code TMT182-

      iTEMP TMT182, koptransmitter HART

      Temperatuurtransmitter, Protocol HART. Toepassing: RTD, TC, TC, Ohm, mV. 2-draads 4-20mA, SIL2, galvanische isolatie. Foutreactie: NAAM NE 43. Montage: kopvorm B, DIN EN50446. UL vermeld.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-draads temperatuurtransmitter. Dubbele universele sensoringang. Galvanische scheiding 2 kV (input/ output). Toepassing: RTD, TC, Ohm en mV. :: Zeer betrouwbaar door drift detectie en sensor back-up. :: Optioneel ook voor veiligheidskritieke applicaties door middel van SIL 2/3 acc. naar IEC61508

    • Order code DIENST-
    • Order code TR13-

      RTD Temperatuursensor TR13

      Pt100 temperatuursensor met geflensde procesaansluiting, nek en pijpthermowell conform DIN 43772 vorm 2F/3F. Geschikt voor algemeen gebruik en lichte chemische toepassingen. Vervangbare mineraalgeïsoleerde inzet met Pt100. Inzetbaar van -50 tot +400° en van -200 tot +600°C, afhankelijk van type Pt100

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.