Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10
Raman bio sleeve
The bio multi optic is a critical part for easy, reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectral quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable bio sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactors.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance for bioprocessing
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
Optimized spectral performance when used with a compatible bio sleeve
High-end producten
Technische topkwaliteit
Eenvoud
Eenvoudige producten
Technische topkwaliteit
Eenvoud
Standaardproducten
Technische topkwaliteit
Eenvoud
Gespecialiseerde producten
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | NL | Kies andere taal | |
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Taal: |
Engels |
Versie: |
31/05/2023 |
Bestandsgrootte: |
467.9 KB |
Bestandsnaam: |
TI01635CEN_0322.pdf |
System design and specifications for the multi optic calibration
and verification kit
EN | NL | Kies andere taal | |
26/06/2023
|
|
|
Taal: |
Engels |
Versie: |
26/06/2023 |
Bestandsgrootte: |
478.7 KB |
Bestandsnaam: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for the Raman Rxn-10 probe
EN | NL | Kies andere taal | |
13/11/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Taal: |
Engels |
Versie: |
13/11/2024 |
Bestandsgrootte: |
929.9 KB |
Bestandsnaam: |
TI01629CEN_0424.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | NL | Kies andere taal | |
31/05/2023
|
|
|
|
03/08/2022
|
|
|
|
14/09/2021
|
|
|
Taal: |
Engels |
Versie: |
31/05/2023 |
Bestandsgrootte: |
1.8 MB |
Bestandsnaam: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
EN | NL | Kies andere taal | |
26/06/2023
|
|
|
Taal: |
Engels |
Versie: |
26/06/2023 |
Bestandsgrootte: |
996.4 KB |
Bestandsnaam: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
EN | NL | Kies andere taal | |
02/12/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Taal: |
Engels |
Versie: |
02/12/2024 |
Bestandsgrootte: |
1.2 MB |
Bestandsnaam: |
BA02160CEN_0424.pdf |
Quick start guide for the Raman Rxn-10 probe
EN | NL | Kies andere taal | |
02/12/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Taal: |
Engels |
Versie: |
02/12/2024 |
Bestandsgrootte: |
1.6 MB |
Bestandsnaam: |
KA01546CEN_0424.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | NL | Kies andere taal | |
31/05/2023
|
|
|
|
03/08/2022
|
|
|
|
14/09/2021
|
|
|
Taal: |
Engels |
Versie: |
31/05/2023 |
Bestandsgrootte: |
1 MB |
Bestandsnaam: |
KA01551CEN_0322.pdf |
Graphic illustrating the core elements of Biopharma 4.0 including
product lifecycle stages, role of PAT/QbD, and 12 key advanced
technologies for scientists and process engineers in the Life
Sciences, applicable to Raman spectroscopy systems (Raman
Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and
sleeve, flow cell and flow bench, Raman optic system for single
use, and Raman calibration & verification kits).
Taal: |
Engels |
Versie: |
22/05/2025 |
Bestandsgrootte: |
481.6 KB |
Bestandsnaam: |
PU01614CEN_0125.pdf |
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).
Taal: |
Tsjechisch |
Versie: |
06/09/2024 |
Bestandsgrootte: |
381.4 KB |
Bestandsnaam: |
PU01584CEN_0124_cz_view.pdf |