Ultrasone clamp-on-flowmeter Proline Prosonic Flow P 500 – niet-invasief en eenvoudig te installeren – geen procesonderbreking – onderhoudsvrije werking tot 550 °C
Proline Prosonic Flow P 500 voor leidingen met leidingdiameters DN 15 tot 65 (½ tot 2½")
F
L
E
X
Als de ruimte beperkt is: ultrasone clamp-on-flowmeter met FlowDC-functie voor consistent hoge prestaties zelfs bij een inlaatlengte van slechts 2 x DN
Bekroonde clamp-on sensor voor hoge temperaturen: Prosonic Flow P 500 heeft de AMA Innovation Award 2025 gewonnen
Ultrasone clamp-on-flowmeter Proline Prosonic Flow P 500 – niet-invasief en eenvoudig te installeren – geen procesonderbreking – onderhoudsvrije werking tot 550 °C
Overzicht specificaties
Max. meetfout
Volume flow: ±3% o.r. for DN 15 ±2% o.r. for DN 25 to DN 200 ±2% o.r. above DN 200
Measuring range
0 to 15 m/s (0 to 50 ft/s)
Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F) DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F) DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F)
Prosonic Flow P 500 is de optimale ultrasone clamp-on-flowmeter voor veilige en onderhoudsvrije metingen van geleidende en niet-geleidende vloeistoffen, zelfs bij uitdagende toepassingen. Deze meet flow niet-invasief en bidirectioneel, wordt niet beïnvloed door druk, dichtheid en geleidbaarheid, en dit zonder procesonderbreking. Met FlowDC is de montage zo flexibel als nooit tevoren. De opgegeven nauwkeurigheid wordt gehandhaafd bij een inlaatlengte van slechts 2 x DN, zelfs bij verstoorde flowprofielen.
Speciale koppelpads maken dit ultrasone clamp-on-systeem onderhoudsvrij gedurende de hele productlevenscyclus.
Tevens is de Prosonic Flow P 500 leverbaar met:
hoge-temperatuursensoren voor metingen tot 550 °C (1022 °F)
een Petroleum Application Package (PAP), die het standaardvolume voor vloeibare koolwaterstoffen berekent
Heartbeat Technology, waarmee continu procestransparantie wordt gewaarborgd. Op deze manier kan aangroei worden ontdekt voordat deze de werking verstoort
Voordelen
Flexibele montage – FlowDC beperkt inlaatlengtes tot een minimum
Strenge veiligheidsnormen – Prosonic Flow P 500 is ontwikkeld volgens IEC 61508 functionele veiligheidsvereisten en voldoet aan internationale goedkeuringen voor gevaarlijke omgevingen, zone 1 en klasse I, divisie 1
Betrouwbare meetprestaties – – beproefde sensoren in combinatie met onderhoudsvrij montagesysteem leveren langdurig stabiele signalen, ook bij hoge temperaturen (≤550 °C/1022 °F)
Gebruiksvriendelijke bediening – de webserver biedt volledige toegang op afstand, terwijl het aanraakdisplay van het instrument gemakkelijke on-site interactie mogelijk maakt
Transparante procesinzichten – Heartbeat Technology met zijn geïntegreerde diagnose-, verificatie- en bewakingsfuncties zorgt steeds voor naleving van de regels en procesveiligheid
Lage investeringskosten – kostenefficiëntie neemt toe met de pijpdiameter (tot DN 4000/160")
Video's
Smart instrumentatie door Heartbeat Technology
U wilt de prestaties van uw installatie verhogen en de kosten verlagen? Ons smart instrumentatie portfolio met Heartbeat Technology biedt een grondig inzicht in de apparatuur voor meer kostenefficiëntie en operationele veiligheid.
Schluchseewerk AG wanted to record and optimize the efficiency of its turbines at the pumped storage plant in Wehr. Endress+Hauser offers the optimum solution with its ultrasonic clamp-on flowmeter.
Forbes Technologies vertrouwt op de instrumenten van Endress+Hauser voor zijn scrubbersystemen en met name Proline Promag W 10 in 0 x DN-uitvoering met volle doorlaat en bluetooth®-connectiviteit.
De Vialit Group produceert diverse producten voor wegenonderhoud. Bij het mengen van halffabricaten zijn nauwkeurige metingen van de flow en de viscositeit van groot belang. Promass I 500 is bij uitstek geschikt hiervoor.
Westlake Vinnolit uses chlor-alkali electrolysis to produce chlorine, caustic soda and hydrogen, relying on Promag Proline P 300/500 as an accurate flowmeter that is immune to electrical interference.
Clamp-on flowmeter for limited spaces in process industries with up to 3 I/Os. Constant accuracy even when mounted with short inlet run thanks to FlowDC. Bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals.
Sensor features
High safety standards – SIL by design, international hazardous area approvals. Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available. Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature: –40 to +550 °C (–40 to +1022 °F).
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range
Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160")
Volume flow: ±3% o.r. for DN 15 ±2% o.r. for DN 25 to DN 200 ±2% o.r. above DN 200
Measuring range
0 to 15 m/s (0 to 50 ft/s)
Max. process pressure
N/A
Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F) DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F) DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F) –50 to +60 °C (–58 to +140 °F) optional
Sensor housing material
N/A
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Degree of protection
Sensor remote version: IP68 type 6P Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation
4-line backlit display with touch control(operation from outside) Optional: WLAN Configuration via local display and operating tools possible
Outputs
3 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output
Inputs
Status input 4-20 mA input
Digital communication
HART, Modbus RS485
Power supply
DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX, FM/CSA, EAC, UK Ex, KC
Other approvals and certificates
Other approvals and certificates
Product safety
CE, C-tick, EAC-marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100 Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
WirelessHART and/or Bluetooth® communication interface, Operating frequency: 2.4 GHz (ISM band), Transmission range under reference conditions: WirelessHART communication - up to 200 m (656 ft), Bluetooth communication - up to 40 m (131 ft)
WirelessHART and/or Bluetooth® communication interface, Operating frequency: 2.4 GHz (ISM band), Transmission range under reference conditions: WirelessHART communication - up to 200 m (656 ft), Bluetooth communication - up to 40 m (131 ft)
We maken gebruik van cookies om uw browse-ervaring te verbeteren, statistische gegevens te verzamelen om de site-functionaliteit te optimaliseren en om reclame of content op maat te presenteren.
Door "Accepteer alles" te selecteren gaat u akkoord met ons gebruik van cookies.
Bekijk voor meer details onze cookie-richtlijnen .