Hydrostatic
Level measurement
Deltapilot FMB70

Deltapilot FMB70 hygienic housing ©Endress+Hauser
Deltapilot FMB70 aluminum housing ©Endress+Hauser
Deltapilot FMB70 separate housing ©Endress+Hauser
Deltapilot FMB70 separate housing hygienic ©Endress+Hauser

Pressure measuring principle

Deltapilot FMB70 ©Endress+Hauser

Highest performance pressure sensor with the Contite cell for hydrostatic level measurement

The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.

  • Voordelen

    • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation

    • Best batch-to-batch repeatability and long-term stability

    • ...

  • Toepassingsgebied

    For level and/or pressure measurement.

    • Process connections: Threads, flanges and hygienic connections

    • Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

    • Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)

    • Accuracy: ±0.075%

    • International...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Hydrostatic

  • Characteristic / Application

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version
    Modular Deviceplatform

  • Specialities

    Diagnostic functions

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC (Non Ex)

  • Accuracy

    Standard 0,1%
    Optional 0,075%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Process pressure absolute / max. overpressure limit

    40 bar (600 psi)

  • Pressure measuring range

    100mbar...10bar
    (1.5psi...150psi)

  • Main wetted parts

    Alloy C
    316L

  • Process connection

    Thread:

    G1 1/2, MNPT1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Max. measurement distance

    100m (328ft) H2O

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175, MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approval

    GL/ DNV

  • Drinking water approvals

    NSF

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing

    Separate housing

  • Application limits

    Measuring cell: Contite,
    condensate-proof, watertight,
    metal welded

    If pressurized, possibly use
    differential pressure measurement
    with two pressure
    transmitters. Observe ratio
    head pressure : hydrostatic
    pressure

  • Meetprincipe

    Hydrostatic pressure

  • Characteristic

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version
    Modular Deviceplatform

  • Supply voltage

    4...20 mA HART

    10,5...45 VDC (Non Ex):

    Ex ia: 10,5...30 VDC

    PROFIBUS PA:

    9...32 VDC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 VDC (Non Ex)

  • Reference Accuracy

    Standard 0,1%
    Optional 0,075%

  • Long term stability

    0,05% of URL/year

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Measuring cell

    100 mbar...10 bar
    (1.5 psi...150 psi)

  • Smallest calibratable span

    25 mbar (3.63 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. overpressure limit

    40 bar (600 psi)

  • Process connection

    Thread:

    G1 1/2, MNPT1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Material process membrane

    316L, AlloyC,

    Gold-Rhodium

  • Material gasket

    None, measuring cell welded

  • Fill fluid

    Inert oil,

    Synthetic oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175
    MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approvals

    GL, DNV

  • Drinking water approvals

    NSF

  • Specialities

    Gold-rhodium coated membrane

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 12
    • Nr 12 Order code 52020440

      Montageset behuizing / sensor

      Bestaat uit: 2x O-ring 45,69x2,62 EPDM. Behoudring, kunststof. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 12 Order code 71020596

      Mounting set housing T17 / sensor

      Bestaat uit: 2x O-ring 45,62x69x2,62 EPDM. 1x profielpakking 51.4x57.2x1.6 EPDM. Behoudring, kunststof. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

  • 13
    • Nr 13 Order code 52022418

      DELTABAR S(7X) 2 BEDIENINGS TOETSEN V2.0

      Bestaat uit: drukknop, deksel + schroeven. Gebruik: externe werking, FMB70, FMD76/FMD77/FMD78,PMC71, PMD70/PMD75,PMP71/PMP75.

    • Nr 13 Order code 52024110

      DELTABAR S (7X) 3 BEDIENINGSTOETSEN V2.0

      Bestaat uit: Drukknop, deksel + schroeven. Kleur donkergrijs. Gebruik: externe werking, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

  • 15
    • Nr 15 Order code 52020760

      Wartel M20x1.5, gasket

      Bestaat uit: Kabelwartel M20. O-ring 18.72x2.62 VMQ. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 15 Order code 52020761

      Cable entry G1/2, gasket, adapter

      Bestaat uit: Pakking 18,72x2,51 NBR. Adapter M20> G1/2. O-ring 18,77x1,78 NBR. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020762

      Plug 2/7-pole, HAN7D, gasket

      Bestaat uit: harting plug set. Gebruik: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Order code 52020763

      Plug 3-pole, M12, gasket

      Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Order code 52006263

      Connector M12x1,5 rechte uitvoering

      M12-aansluiting voor plug. Self confectionery connection. Gebruik: plug M12. Dit betreft een product uit het E-direct portfolio met een scherpe netto prijs. Kijk voor meer informatie op www.e-direct.endress.com

    • Order code 71043576

      Set behuizing filter T14/T15, 3 stuks

      Bestaat uit: Filter plug, Gore-Tex filter. Gebruik: Behuizing T14, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70. Gebruik: Behuizing T15, FMB70.

    • Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Bestaat uit: Vent schroef 304, compensatie druk filter, O-ring EPDM, dekseltje. Gebruik: Huisvesting T14, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD72. Behuizing F31, FMB50/51/52/53, PMC51, PMP51/PMP55. Behuizing F15 w / o B1, BB, BD, BF, GA, ID, I1, FMB50/51/52/53, PMC51, PMP51/PMP55.

    • Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Bestaat uit: Vent schroef 304, compensatie druk filter, O-ring VMQ, dekseltje. Usage: Huisvesting T17, PMC71, PMP71 / PMP75, PMD70/PMD75, FMD76/FMD77/FMD78. Huisvesting F15 voor B1, BB, BD, BF, GA, ID, I1, FMB50/51/52/53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Order code 52020432

      Deksel T14/T15 Alu, dichting

      Materiaal: aluminium, gecoat. O-ring EPDM, FDA. Niet voor EEx d/XP. Gebruik: FMB70,FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002774

      Deksel T17 316L, pakking

      Materiaal: 316L. Vlakke pakking EPDM, centreer ring, schroef. Niet voor EEx d/XP. Gebruik: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 25
    • Nr 25 Order code 71002774

      Deksel T17 316L, pakking

      Materiaal: 316L. Vlakke pakking EPDM, centreer ring, schroef. Niet voor EEx d/XP. Gebruik: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 20
    • Nr 20 Order code 71002810

      Cover T17 316L, sight glass, gasket

      Materiaal: 316L. Kijkglas: mineraalglas. Platte pakking EPDM, centrerende ring, schroef. Voor goedkeuring 2,3,4,7,8, Q, W. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75. Voor goedkeuring BC, BD,IB. Gebruik: FMD71/FMD72.

    • Nr 20 Order code 71002811

      Deksel T17 316L, met venster PC, o-ring

      Materiaal: 316L. Kijkglas: Polycarbonaat PC. Platte pakking EPDM, centrerende ring, schroef. Voor goedkeuring A,E,F,H,I,R,S,U,1,6. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75. Voor goedkeuring AA,BA,CA,CB,CC,CD,FA, FB,FD,IA. Gebruik: FMD71/FMD72.

    • Nr 20 Order code 71245247

      Cover T14/T15 Alu, sight glass, gasket

      Material: Aluminium, coated. Sight glass Mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMD71/FMD72, FMB70.

  • 21
    • Nr 21 Order code 52020429

      Dichtingsset EPDM, deksel T14, 5 stuks

      Bestaat uit: 5x O-ring 75,87x2.62, EPDM,PTFE,FDA. Gebruik: Huisvesting 30/F31/F34,T14/T15.

    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD71/FMD72, FMD77/FMD78, FMB70,housing T14/T15/T17. PMC51, PMP51/PMP55, FMB50/FMB51/FMB52/FMB53, PMD55, housing F30/F31.

  • 25
    • Nr 25 Order code 52020432

      Deksel T14/T15 Alu, dichting

      Materiaal: aluminium, gecoat. O-ring EPDM, FDA. Niet voor EEx d/XP. Gebruik: FMB70,FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 30
    • Nr 30 Order code 71026358

      FMB70 electr. bediening op elektronika

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, versie 02.10.zz. Drukknop op de behuizing. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 30 Order code 71071824

      Elektronica PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware versie 02.00. Software versie 04.00.zz. Huidig verbruik 13mA + / - 1 mA. Drukknop op elektronica. Usage: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70.

    • Nr 30 Order code 71071825

      Electronics PA, ext. p. b.,HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071826

      Electronics FF, HW02.00, SW3.0

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071827

      Electronics FF, ext. p. b.,HW02.00,SW3.0

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71196092

      Electronic HART Ex, v2.11

      4-20mA, versie 02.11.zz. Druk op de knop op elektronica. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78,FMB70. Niet voor MID delen certificaat (PMP71).

    • Nr 30 Order code 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, versie 2.11.zz. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70. Niet voor MID delen certificaat (PMP71).

    • Nr 30 Order code 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware-versie 02.00. software versie 04.00.zz, FF, DevRev07. Stroomverbruik 15mA +/- 1 mA. Druk op de knop op de behuizing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70. Niet voor mariene certificaat en SIL.

    • Nr 30 Order code 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware-versie 02.00. software versie 04.00.zz, FF, DevRev07. Stroomverbruik 15mA +/- 1 mA. Drukknop op elektronica. Gebruik: PMC71, PMP71/PMP75,PMD70/PMD75, FMD76/FMD77/FMD78,FMB70. Niet voor SIL.

    • Nr 30 Order code 71263933

      Electronics HART Ex, v2.20

      4-20 mA. Softwareversie 02.20.zz, HART 7, DevRev22. Drukknop op elektronica. Gebruik: PMC71,PMP71/PMP75, PMD75,FMD77/FMD78,FMB70. Niet voor MID onderdelen certificaat (PMP71).

    • Nr 30 Order code 71263934

      Electronics HART Ex, ext. p. b., v2.20

      4-20 mA. softwareversie 02.20.zz, HART 7, DevRev22. Drukknop op de behuizing. Gebruik: PMC71, PMP71 / PMP75, PMD75, FMD77 / FMD78, FMB70. Niet voor mariene certificaat. Niet voor MID onderdelen certificaat (PMP71)

    • Nr 30 Order code 71386147

      Elektronics HART Ex, v2.30

      4-20 mA. Softwareversie 02.30.zz, HART 7, DevRev23. Drukknop op elektronica. Gebruik: FMB70,FMD77/FMD78,PMC71, PMD75, PMP71/PMP75. Niet voor MID-onderdelencertificaat (PMP71).

    • Nr 30 Order code 71386153

      Electronics HART Ex, ext. p. b., v2.30

      4-20 mA. Softwareversie 02.30.zz, HART 7, DevRev23. Drukknop op behuizing. Gebruik: FMB70, FMD77/FMD78,PMC71, PMD75,PMP71/PMP75. Niet voor MID-onderdelencertificaat (PMP71).

  • 31
    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostische software inbegrepen. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostische software inbegrepen. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

  • 35
    • Nr 35 Order code 52020434

      Terminal 3-pole, RFI, HART, TIIS

      RFI-filter. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75, TIIS Ex ia.

    • Nr 35 Order code 52026605

      Terminal 2-pole, RFI, PA, TIIS

      RFI filter. PROFIBUS PA. Gebruik: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.

    • Nr 35 Order code 52027691

      Terminal 2-pole, RFI, FF, Ex

      RFI-filter. FOUNDATION Fieldbus. Gebruik: FMB70, FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 35 Order code 71028473

      Terminal 3p., RFI, HART, OVP, TIIS

      Overspanningsbeveiliging, RFI-filter. Gebruik: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028475

      Uiteinde 2-polig, RFI, PA, OVP, Ex

      Overspanningsbeveiliging, RFI-filter. PROFIBUS PA. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB70.

    • Nr 35 Order code 71028476

      Terminal 2-pole, RFI, FF, OVP, Ex

      Overspanningsbeveiliging, RFI-filter. FOUNDATION Fieldbus. Gebruik: FMB70,FMD76/FMD77/FMD78, PMC71,PMD70/PMD75,PMP71/PMP75.

    • Nr 35 Order code 71121574

      Terminal 2-pole, RFI, PA, Ex

      RFI filter. PROFIBUS PA. Gebruik: FMB70, PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, Niet voor TIIS

    • Nr 35 Order code 71191892

      Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd

      RFI-filter. Gebruik: PMC71,PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70,FMD71/FMD72. Niet voor TIIS Ex ia, TIIS Ex d.

    • Nr 35 Order code 71191894

      Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd

      Overspanningsbeveiliging, RFI-filter. Gebruik: PMC71/PMP71/PMP75, PMD70/PMD75,FMD76/FMD77/FMD78, FMB70,FMD71/FMD72. Niet voor TIIS Ex ia, TIIS Ex d.

  • 40
    • Nr 40 Order code 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digitaal display, 3 drukknoppen, Gebroken beugel. Talen DE/EN/FR/ES/IT/NL, Van software versie 02.00.zz; Gebruik: elektronica HART. Talen DE/EN/FR/ES/IT/NL/JA/ZH. Van software versie 02.01.zz; Elektronica HART. Talen DE/EN/FR/ES/IT/JA/ZH/RU, Van software versie 02.11.zz; Elektronica HART. Van software versie 04.00.zz; Elektronica PROFIBUS PA. Van software versie 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70,FMD76/FMD77/FMD78,PMC71, PMD70/PMD75,PMP71/PMP72/PMP75. Van software versie 01.00.zz; Elektronica HART, FMD71/FMD72.

    • Order code 71043886

      Cable PE, L=2m/80inch, separate housing

      Aansluitkabel sensor>sep. housing. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71043888

      Cable PE, L=5m/200inch, separate housing

      Aansluitkabel kabel sensor>sep.behuizing Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71043889

      Cable PE, L=10m/400inch,separate housing

      Aansluitkabel sensor> sep. huisvesting. Gebruik: PMC71, PMP71/PMP75, PMD70/PMD75, FMD76/FMD77/FMD78, FMB50/FMB51/FMB52/FMB70, PMC51/PMP51/PMP55.

    • Order code 71070738

      Cable FEP, L=5m/200inch,separate housing

      Aansluitkabel sensor> sep. huisvesting. Gebruik: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 214880-0002

      Weld-in adapter UNI D65, 316L

      Flush mount process connection. Core hole: 65mm. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.

    • Order code 52002041

      Inlasflens DRD-DN50-316L

      Front-inbouw van apparaten met DRD-flens. Materiaal: 316L. Afdichting: plat PTFE. FDA-compliant. Gebruik:FMB50,FMB70,FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Order code 52006262

      Weld-in adapter UNI D85, 316L

      Inbouw proces-verbinding. Core gat: 85mm. Materiaal: 316L. Seal: siliconen profiel pakking. Gebruik: FMI51/FMI52, FTI51/FTI52, FMP52,FMB70,FMB50, FMD78, FMD71, PMC51, PMP55, PMP75, PMP23.

    • Order code 52010173

      Weld-in adapter UNI D85, 316L, 3.1

      Inbouw proces-verbinding. Core gat: 85mm. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A compliant. Gebruik: FMI51/FMI52, FTI51/FTI52, FMP52,FMB50,FMB70,FMD71,FMD78,PMC51, PMP23,PMP55,PMP75.

    • Order code 52010174

      Weld-in adapter UNI D65, 316L, 3.1

      Inbouw proces-verbinding. Core gat: 65mm. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A compliant. Gebruik: FMI51/FMI52, FTI51/FTI52, FMP52, FMB70, FMB50, FMD71, FMD78, PMC51, PMP23, PMP55, PMP75.

    • Order code 52011899

      Weld-in adapter DRD DN50, 316L, 3.1

      Inbouw proces aansluiting van apparaten met DRD flens. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: PTFE plat. FDA compliant. Gebruik: FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51,PMP51,PMP55,PMC71,PMP75,FMB50, FMB70,FMD78.

    • Order code 52024469

      Laspuntstuk G1-1/2, 316L

      Laspuntstuk G1-1/2 Materiaal: 316L Correcte installatie alleen met dummy. Gebruik:PMC71,PMP71,PMP75,FMB50/FMB51/ FMB52,FMB70,PMC51,PMP51/PMP55.

    • Order code 52024470

      Weld-in adapter G1-1/2, 316L, 3.1

      Montageproces aansluiting G1-1 / 2. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Gebruik: PMC71, PMP71, PMP75, FMB50/51/52, FMB70, PMC51, PMP51, PMP55.

    • Order code 916743-0000

      Weld-in adapter DRD DN50, 304

      Flush mount process connection. Material: 304. Seal: PTFE flat. FDA compliant. Usage: Flush mount FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMP51, PMP55, PMC71, PMP75, FMB50, FMB70, FMD78.

  • 50
    • Order code 52024228

      Vlakke afdichting 50x65x1 PTFE,FDA ,5st.

      Monteer de inlasadapter DRD-DN50. Inbouw FTL50H/FTL51H, PMC51, drukapparaat.

  • 57
    • Nr 57 Order code 52023572

      Siliconen profielafdichting (5 stuks)

      Procespakking universele procesaanpassing. FDA vermeld. Gebruik: FMB50, FMB70, FMI51/FMI52, FTI51/FTI52/FTI55, PMC51.

    • Nr 57 Order code 71100719

      Profieldichting EPDM, 5 stuks

      Process gasket universal adapter. Usage: FMB50, FMB70, PMC51.

    • Order code 71114172

      Adapter Uni, DIN11851 DN40, 316L

      Sleuven-nut, proces-verbinding. Materiaal: 316L. Seal: siliconen profiel pakking. FDA, EHEDG, 3A voldoen. Gebruik: PMC51,FMB50.

    • Order code 71114173

      Adapter Uni, DIN11851 DN50, 316L

      Slotted-nut, proces-verbinding. Materiaal: 316L. Seal: siliconen profiel pakking. FDA, EHEDG, 3A voldoen. Gebruik: PMC51, FMB50 ..

    • Order code 71114174

      Adapter Uni, DRD DN50, 65mm, 316L

      Slotted-nut, proces-verbinding. Materiaal: 316L. Seal: siliconen profiel pakking. FDA, EHEDG, 3A voldoen. Gebruik: PMC51, FMB50.

    • Order code 71114177

      Adapter UNI, Varivent N, 316L

      Universele adapter, Varivent procesaansluiting. Materiaal: 316L. Gebruik: PMC51, FMB50.

    • Order code 71114178

      Adapter UNI, DIN11851 DN40, 316L, 3.1

      Universele adapter, DIN11851 DN40, wartelmoer, procesaansluiting. Materiaal: 316L. Materiaal cert. EN10204-3.1. Gebruik: PMC51, FMB50.

    • Order code 71114205

      Adapter Uni, DIN11851 DN50, 316L 3.1

      Slotted-nut, proces-verbinding. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A te voldoen. Gebruik: PMC51, FMB50.

    • Order code 71114206

      Adapter Uni, DRD DN50, 65mm, 316L 3.1

      Slotted-nut, proces-verbinding. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A te voldoen. Gebruik: PMC51, FMB50.B50.

    • Order code 71114208

      Adapter Uni, Varivent N, 316L 3.1

      Slotted-nut, proces-verbinding. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3A voldoen. Gebruik: PMC51_110_UNJ/UPJ, FMB50_110 UNJ/UPJ.

    • Order code 52024471

      Weld-in dummy, adapter G1-1/2

      Ter voorkoming van vervorming tijdens het lassen van laspuntstuk 52024469 / 52024470.

    • Order code 71114176

      Adapter UNI, Clamp 2", 316L

      Universele adapter, Triclamp 2" procesaansluiting. Materiaal: 316L. Gebruik: FMB50, FMB70, PMC51.

    • Order code 71114178

      Adapter UNI, DIN11851 DN40, 316L, 3.1

      Universele adapter, DIN11851 DN40, wartelmoer, procesaansluiting. Materiaal: 316L. Materiaal cert. EN10204-3.1. Gebruik: PMC51, FMB50.

    • Order code 71114207

      Adapter UNI, Clamp 2", 316L, 3.1

      Slotted-nut, proces-verbinding. Materiaal: 316L. Inspectie cert. NL 10.204-3,1 materiaal. Seal: siliconen profiel pakking. FDA, EHEDG, 3-A te voldoen. Gebruik: PMC51, FMB50.

    • Order code 71114160

      Ìnlas adapter Uni 6" D85, 316L

      Inbouw proces-verbinding. Core gat: 85mm. Materiaal: 316L. Seal: siliconen profiel pakking FDA voldoen. Gebruik: FMB50, FMB70.

    • Order code 71114171

      Inlas adapter Uni 6" D85, 316L, 3.1

      Inbouw proces-verbinding. Kern gat: 85mm. Materiaal: 316L. Inspectie cert. EN10204-3.1 materiaal. Afdichting: siliconen profiel pakking FDA voldoen. Gebruik: FMB50, FMB70.

    • Order code 71304770

      Mountingset, housing T14, special

      Materiaal: 316L. Gebruik: montagekit aan de eigen montagebeugel te hechten/bescherming tegen weersinvloeden. dekking, PMC71, PMP71 / PMP75, FMB70.

    • Order code 71102216

      Montageset Cerabar,Deltapilot,Levelflex

      Materiaal: RVS 304. Geschikt voor: wand/pijp montage (2"), PMC71, PMP71/75, FMB70, PMC51, PMP51/55, FMB50/51/52/53. FMP50/51/52/53/54/55/56/57.

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.