Dissolved oxygen transmitter
Liquisys COM253
Compact field device for water, wastewater, utilities and fish farming
Liquisys COM253 is a standard transmitter for use with COS41 and COS61 oxygen sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
-
Voordelen
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Reliable oxygen control: Current input for flow rate monitoring with controller shut off or for feedforward control.
Easy to operate...
-
Toepassingsgebied
The Liquisys COM253 transmitter works with Oxymax COS41 and Oxymax COS61 dissolved oxygen sensors in environmental applications, such as:
O2 control in the aeration basin
O2 control and monitoring of drinking water
Surface water monitoring
Process...
Documenten / handleidingen / software
-
Liquisys M COM223/253
Technical Information
Transmitter for oxygen sensors
Technische informatie (TI) -
Orbit OOM 223 / 253
Installation and operation guide
Transmitter for dissolved oxygen
Inbedrijfsstellingsvoorschriften (BA) -
Liquisys M COM223/253
Operating Instructions
Transmitter
Inbedrijfsstellingsvoorschriften (BA) -
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
Inbedrijfsstellingsvoorschriften (BA) -
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
Inbedrijfsstellingsvoorschriften (BA) -
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous
areas as per EC Directive 94/9/EC (ATEX)Ex Veiligheidsinstructies (XA) -
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Speciale Documentatie (SD) -
Instructions for service kits Liquisis M
Special documents
Instructions for service kits Liquisis M / CPM253 / CLM253 / COM253 /
CUM253Speciale Documentatie (SD) -
Installation of M 12 plug
Special Documentation Installation of M 12 plug
CPM253 / COM253 / CLM253 / CUM253Speciale Documentatie (SD) -
Saving costs by continuous monitoring of D.O. in wastewater
treatment
plant
Continuous monitoring of D.O. in wasterwater treatment
plant with
Liquisys COM253 D.O. transmitter with
COS61 optical D.O. sensorCase Studie (CS)02/10Engels -
Liquisys COM253
Sauerstoff- und Temperatur Messumformer
Tender tekst12/16Duits -
GSD Single, GSD_EH_DP_AN_Liquisys_0x151E_V02_04_DPLIB, 14.04.2014 (Analys
is, Liquisys M, 0x151E)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.04.00Language neutral -
GSD Single, GSD_EH_PA_AN_Liquisys_0x1518_V02_00_PALIB, 22.04.2014 (Analys
is, Liquisys M, 0x1518)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.00Language neutral -
DTM Single, LiquisysM_COM2x3_PA_V2_40___V2_41, 10.07.2019 (Analysis, Liquisys M, 0x1518)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysM_COM2x3_DP_V2_40___V2_41, 10.07.2019 (Analysis, Liquisys M, 0x151E)
PROFIBUS DP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, LiquisysMDO_COM2x3_V2_40, 09.07.2019 (Analysis, Liquisys M, 0x0094)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Liquisys Chlorine, Liquisys Conductivity, Liquisys Oxygen, Liquisys pH/ORP
Productcode: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253-
verklaring Number: EC_00575_01.17EU DeclarationDuits , Engels , fr -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Productcode: CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS16D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Regio: Russia (Declaration of Conformity)
Keurnummer: EAEC D-DE.AD07.B.01363/19MiscellaneousRussisch -
TOCII, Stip-Scan, Stamolys, Sensor, Mycom S, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Conductivity, Liquisys Chlorine, Liquiline M, Liquiline
Productcode: CPM253-, CPM223-, CPM153-, COM253-, COM223-, CM448-, CM444-, CM442-, CM14-, CLM253-, CLM223-, CLM153-, CCM253-, CCM223-, CAM74-, CA72TOC-, CA71SI-, CA71PH-, CA71NO-, CA71MN-, CA71HY-, CA71HA-, CA71FE-, CA71CU-, CA71CR-, CA71COD-, CA71CL-, CA71AM-, CA71AL-
Regio: Russia (TR CU)
Keuringsinstantie: EAC
Keurnummer: TC № RU D-DE.MU62.B.02737MiscellaneousRussisch -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Productcode: CPS491-, CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91D-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CPS16D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Keurnummer: EAEC RU D-DE.AD07.B.01362/19MiscellaneousRussisch -
LIQUISYS M, OxyMax H, OxyMax W
Productcode: COS71-, COM253F-, COM253-, COM223-, COM223F-, COS61-, COS41-, COS31-, COS21-
Regio: Russia
Keuringsinstantie: Rosstandart
Keurnummer: OC.C.31.004.A_35505MetrologyRussisch -
Liquisys Chlorine, Liquisys Conductivity, LIQUISYS M, Liquisys Oxygen, Liquisys Turbidity, SmarTec S
Productcode: CUM253-, CUM223-, CPM253-, CPM223-, COM253F-, COM253-, COM223F-, COM223-, CLM253-, CLM223F-, CLM223-, CLD134-, CCM253-, CCM223-
Regio: Canada, USA
Keuringsinstantie: CSAOrdinary Location Product SafetyEngels
Accessoires / Spare parts
-
-
Order code 51500320
CxM2x3 relaismodule (2 relais)
Upgrade of LIQUISYS-M basis versie 2 potentiaal vrije wissel contacten
-
-
-
Nr 290 Order code 51511446
KIT CXM2X3 relay mod. 2rel / CSA
Upgrade van LIQUISYS-M basis versie door 2 potentiaalvrije wisselcontacten.
-
-
-
Nr 300 Order code 51500321
CxM2x3 4 RELAISPRINT MET CHEMOCLEAN
Let op Fabriek heeft serienummer nodig !
-
Nr 300 Order code 51511447
KIT CXM2X3 relay mod. 4rel / CSA
-
-
-
Nr 290 Order code 51504304
2-relaiskaart met stroomingang 4-20mA
Upgrade van Liquisys M in basisversie met 2 contacten en stroomingang 4-20 mA
-
-
-
Nr 300 Order code 51504305
4 relaisprint met stroomingang 4-20 mA
Upgrade van Liquisys M basis versie met 4 relais en stroomingang 4-20 mA
-
-
-
Nr 40 Order code 51501225
-
-
-
Nr 60 Order code 51501223
KIT COM2x3 Central module I1 HART
-
-
-
Nr 50 Order code 51501222
COM223 Centraal module LSCH-S2
-
-
-
Nr 70 Order code 51501226
KIT COM2x3 centrale module I2 HART
-
-
-
Nr 80 Order code 51501227
COM2x3 hoofdprint Profibus PA
-
-
-
Nr 90 Order code 51502500
COM2X3 Centraalmodu Profibus DP
-
Nr 90 Order code 71134729
Kit COM2x3:Central modul PB DP; H/W 2.1x
-
-
-
Nr 290 Order code 71134732
Kit CxM2x3: Relay mod. for PBDP; H/W2.1x
Inhoud: 1x Relaismodule Profibus DP 2x relais, 1x Stroomingang DP- aansluiting gekwalificeerd vanaf H/W 2,10
-
-
-
Nr 250 Order code 51501207
COM2x3 O2 transmitter MK01 (DX/DS)
-
Nr 250 Order code 51501208
COM2x3 O2transmitterMK01(DX/DS)luchtdruk
-
-
-
Nr 260 Order code 51506938
COM2x3 (-WX/WS) O2 + luchtdr KIT
-
-
-
Nr 10 Order code 51500317
CxM2x3 voeding AC
-
-
-
Nr 20 Order code 51500318
-
-
-
Nr 410 Order code 51501068
KIT CXM253 housing cover
-
-
-
Nr 335 Order code 71071446
Kit CxM253: Front foil + 6 key lifters
-
-
-
Order code 51506966
KIT COM253 sensor panel jack SXB
-
-
-
Nr 330,340,450, Order code 51501073
CXM253 moederprint met binnenbehuizing
-
-
-
Nr 260,490 Order code 51517800
upgrade kit COS naar COS31 of COS61
-
-
-
Nr 400 Order code 51501072
CXM253 behuizing onderzijde
-
-
-
Nr 430 Order code 51501069
CPM253 scharnierset voor deksel
-
-
-
Nr 470 Order code 51501079
CPM253 konnektor voedingsspanning
-
-
-
Nr 310 Order code 51501074
CXM253 displaykabels
-
-
-
Order code 50086842
Mastmontageset voor LIQUISYS
voor montage van de veld-transmitters op horizontale en verticale pijpen max. diameter 60 mm Materiaal: roestvrij staal V2A
-
Order code 51500385
CxM2x3 PLUSPAKKET KIT
Upgrade of LIQUISYS-M basic version (parameter pH,Cond.,Tu,CL,O2 (WX to WS)) to S-version (plus-package). Serial number of instrument needed.
-
Order code 51501679
Upgrade "Plus-Package" for COM 2X3
Upgrade of Liquisys-M basic version (parameter DO (DX to DS)) to S-version (plus-package). Serial number of instrument needed.
-
Order code 51500963
UPGRADE CLEANING VOOR LIQUISYS-M
Upgrade of LIQUISYS-M basic version by cleaning functionality (Chemoclean) (serial number of instrument needed). If not yet installed, a 4-relay board must be ordered separately (51500321).
-
-
Voorganger