Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
Tankvision NXA820 - voorraadbeheer

Tankvision
voorraadbeheer
Tank Scanner NXA820

Krijgt gegevens van procesinstrumenten

NXA820
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
Bezig met activeren van prijs
Prijs: Informatie verstrekken
Filter meting-/ toepassingstaak
Meet-/toepassingstaak

Configureer om de CAD-tekeningen van dit product te downloaden

  • Meetprincipe

    Inventory Management Solutions

  • Application Task

    Data acquisition
    Data management
    Process monitoring &
    visualization

  • Field of Application

    Tankvision Tank Scanner NXA820 is a device with embedded web server for installation in a cabinet. It collects measurements from connected field devices for up to 15 tanks and calculates volumes and masses for visualization and operation of storage facilities in the Oil & Gas industry.

  • Monitor resolution, display

    1280 x 1024 (or better)

  • Interfaces

    OPC classic
    Rest API
    Tankvision Data Concentrator NXA821
    Tankvision Host Link NXA822
    Tankvision Professional NXA85

  • Meetprincipe

    Communication Interface

  • Function

    Device with embedded web server for data acquisition and processing of field devices for up to 15 tanks.

  • Input

    Modbus RS485
    Modbus RS232
    Modbus TCP
    Sakura V1
    Whessoe WM550
    Tankvision Gauge Link NXA20

  • Output

    OPC classic
    Rest API
    Tankvision Data Concentrator
    Tankvision Host Link NXA822
    Tankvision Professional NXA85

  • Relay output signal type

    Potential free relay, SPDT
    Normally-closed when NXA is operating normally, open when NXA is powered off or fault status exists
    Switching power:
    - 25 V DC, 100 W
    - 250 V DC, 4 A, 1000 VA

  • Memory

    128 MB

  • Power supply

    90 - 250 V AC (50/60 Hz)
    10.5 - 32 V DC

  • Dimensions (WxHxD)

    91 mm x 104 mm x 140 mm
    (3.6 in x 4.1 in x 5.5 in)

  • Communication interface

    Ethernet

  • Operation

    Web server

  • Configuration

    Web server

  • Certificates

    OIML R85 (2008): Compliance tested by NMi
    NMi
    PTB

  • Meetprincipe

    Level radar

  • Characteristic / Application

    Device with embedded web server for data acquisition and processing of field devices for up to 15 tanks

  • Communication

    Ethernet

  • Metrological approvals and certificates

    OIML R85 (2008): Compliance tested by NMi
    NMi
    PTB

  • Options

    Potential free relay, SPDT
    Normally-closed when NXA is operating normally, open when NXA is powered off or fault status exists
    Switching power: -25 V DC, 100 W - 250 V DC, 4 A, 1000 VA