Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis

Ultrasonic measurement
Time-of-Flight
Prosonic FMU41

Prosonic FMU41 ©Endress+Hauser

Time-of-Flight measuring principle

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 8m

The Prosonic FMU41 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

Snelle selectie

Kies uit één van de voorgestelde opties
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

of

Individuele configuratie

Ga verder met uw keuze uit alle mogelijke opties
  • Voordelen

    • Reliable non-contact measurement

    • Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable

    • Envelope curves on the on-site display for simple diagnosis

    • Hermetically sealed and potted sensor

    • ...

  • Toepassingsgebied

    Two-wire or four wire instrument for continuous non-contact level and flow measurement.

    • Process connection: Thread

    • Temperature: -40 to +80°C (-40 to +176°F)

    • Pressure: +0.7 to +3bar (+10 to +44psi)

    • Maximum measuring distance: Liquids 8m (26ft), Solids 3...

Details

  • Meetprincipe

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 2 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 2"

  • Blocking distance

    0.35 m (1.15 ft)

  • Application

    Application

  • Max. measurement distance

    Max. measurement distance

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, TIIS, INMETRO, NEPSI

  • Application limits

    Application limits

  • Meetprincipe

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 2 mm or +/- 0,2 % of set measuring range 1)

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 44 psi)

  • Main wetted parts

    PVDF

  • Process connection

    G / NPT 2"

  • Blocking distance

    0.35 m (1.15 ft)

  • Max. measurement distance

    3.5 m (11 ft)

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, TIIS, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

  • Meetprincipe

    Ultrasonic

  • Product headline

    Compact ultrasonic measuring instrument
    Cost effective solution for open channels

  • Max. measurement error

    Low accuracy

  • Measuring range

    Measuring distance 0,4...8m [1.3...26ft]

  • Max. process pressure

    atm.

  • Medium temperature range

    -40°C...80°C
    (-40°F...176°F)

  • Degree of protection

    IP68

  • Outputs

    4...20mA(Hart),PA,FF

  • Inputs

    2-wire 16-36V DC
    4-wire 16-36V DC
    90-253V AC 50/60Hz

  • Digital communication

    PROFIBUS PA, FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX, FM, CSA

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
    • Order code 52006628

      Instrument plug M20-M12 "PA" (WDM)150

      Aansluiting: M20 wartel Verbinding: M12 connector met leads 0,75 mm2, lengte 150 mm Pin aansluiting A: PA- S: Screen B: PA+ n.c.: Niet aangesloten

  • 12
    • Nr 12 Order code 535720-9020

      Set of screws housing F12/T12/F23

      Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

  • 65
    • Nr 65 Order code 52010526

      FMP-M O ringenset

      Consists of: 1x O-ring 113.9x3.53 EPDM. 1x O-ring 72.0x3.0 EPDM. 1x O-ring 49.21x3.53 EPDM. 1x flat gasket 47x58x2 EPDM. 1x flat gasket 59x68x2.5 EPDM. 2x O-ring 17.0x2.0 EPDM. Usage: FMU40/FMU41/FMU42/ FMU43/FMU44.

  • 20
    • Nr 20 Order code 517391-0011

      Cover F12/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 20 Order code 52005936

      FMR23x/24x deksel m.glas T12

      Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.

  • 11
    • Nr 11 Order code 52005643

      FMX-M afdekplaat T12 behuizing

      Cable compartment, electronics side. Usage: Micropilot M/S, Prosonic M, Levelflex M.

    • Nr 11 Order code 52006026

      FMX-M DEKSEL F12, AANSLUITRUIMTE

      Overkapping voor uiteinde Micropilot M, Prosonic M, Levelflex M

    • Nr 11 Order code 52019062

      Cover terminal compartment F12/F23,FHX40

      Hood terminal compartment. Usage: separate display, Micropilot M, Prosonic M, Levelflex M.

  • 25
    • Nr 25 Order code 518710-0020

      Cover T3/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.

  • 35
    • Nr 35 Order code 52006197

      Terminal module 4-pole, HART, 2-wire

      Kabelaansluiting. Gebruik: behuizing F12/F23, Micropiloot M, Levelflex M, Prosonic M.

    • Nr 35 Order code 52012156

      FMP-M F12 aansluitmodule PA en FF

      PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.

    • Nr 35 Order code 52013302

      FMP40 T12 aansluitmodule HART

      Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.

    • Nr 35 Order code 52013303

      FMP40 T12 aansluitmodule PA/FF

      2-wire, PROFIBUS PA/FOUNDATION Fieldbus. Ex d limiter. Usage: housing T12, Levelflex M, Micropilot M, Prosonic M.

    • Nr 35 Order code 52013304

      FMP40 voeding voor 4 dr. 10,5..32 V DC

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Order code 52013305

      Voeding 90-250VAC (F12), alleen Ex

      Gebruik: 4-draads elektronica, Levelflex M (Non-Ex en Ex), Prosonic M (alleen Ex).

    • Nr 35 Order code 52015585

      Power supply CSA, 10.5-32VDC (housg F12)

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Order code 52015586

      Power supply CSA, 90-250VAC (housg F12)

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Order code 52018949

      FMR250 aansluitmod. T12 Hart EExia

      4-pole, 2-draads voor Aluminium T12 behuizing OVP = overvoltage bescherming Levelflex M, Prosonic M, Micropilot M

    • Nr 35 Order code 52018950

      FMR250 aansluitmod. T12 PA/FF EExia,

      2-pole, 2-draads PROFIBUS PA, FOUNDATION Fieldbus voor Aluminium T12 behuizing OVP = overvoltage bescherming Levelflex M, Prosonic M, Micropilot M

    • Nr 35 Order code 71396869

      Power supply 90-250VAC (F12) v2, Non-Ex

      Stroomvoorziening, HART, versie 2. Alleen voor "niet-ex-gebied". Gebruik: FMU40/FMU41/FMU42/FMU43/FMU44.

  • 30
    • Nr 30 Order code 71025600

      FMU4x elektronika 2 dr. HART V4.0

      4-20mA, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 30 Order code 71025602

      FMU4x elektronika 4 dr. HART V4.0

      4-20mA, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 30 Order code 71025603

      FMU4x elektronika PA V4.0

      PROFIBUS PA, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 30 Order code 71025604

      Electronica FMU4x,Ex,FF,V4.0

      FOUNDATION Fieldbus, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.

  • 40
    • Nr 40 Order code 52026443

      FMX-M BEDIENINGSMODULE VU331

      4-Lijns alfanumerische weergave. Gebruik: FMR530/532/533, FMR540, FMU40/41/42/43/44.

    • Order code FHX40-

      Display FHX40

      Remote display + local operation. 4-line LC-display. :: Menu driven plain text operation. :: Easy setup. :: User language selectable. :: Envelope curve display on site. Usage: FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.

  • 50
  • 58
    • Order code

      Screw in flange FAX50 please order with separat order structure.

    • Order code 52018204

      FHX40 ADAPTERSET F12 HUIS 2 DRAADS INSTR

      Voor modificatie naar separate display met F12 behuizing and 2-draads elektonica

    • Order code 52018205

      FHX40 ADAPTERSET F12 HUIS 4 DRAADS INSTR

      Modification to remote display. Housing F12, 4-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Levelflex M, Prosonic M.

    • Order code 52016334

      Kabel FHX40, 20m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71020502

      Kabel FHX40, 5m

      Verbindingskabel, dubbel afgeschermd. Gebruik: FHX40.

    • Order code 71020503

      Kabel FHX40, 10m

      dubbel geïsoleerde connectie kabel voor FHX40 display

    • Order code 71020504

      Kabel FHX40, 30m

      Verbindingskabel, dubbel afgeschermd. Gebruik: FHX40.

    • Order code 71007843

      ToF Adapter FXA291

      Gebruik: aansluiting Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, Commubox FXA291.

    • Order code 543199-0001

      Protective cover for housing T12/F12, SS

      Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.

    • Order code 71000221

      Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60

      Verbinding RS232(52013675)/ ToF adapter FXA291 (71007843). Gebruik: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.

    • Order code 52013874

      Montagesteun voor buis 2"

      voor aanduider FHX40

    • Order code 942669-0001

      Installat_bracket 250x400x120 G2

      Material: 316Ti. Usage: Prosonic T/M, FMR10, FMR20.

    • Order code 52014135

      Sensorhouder 500mm, st, 2" sensor

      Montage 2 "-sensor. Materiaal: staal verzinkt. Gebruik: montagebeugels, FMR10/FMR20.

    • Order code 52014136

      Sensorhouder 500mm, SS 2" sensor

      Montage 2 "-sensor. Materiaal: 316Ti. Gebruik: montagebeugels, FMR10/FMR20.

    • Order code 52014137

      Sensorhouder 1000mm, ST, 2" sensor

      Montage 2"-sensor. Materiaal: staal verzinkt. Gebruik: montagebeugels, FMR10/FMR20.

    • Order code 52014138

      Sensorhouder 1000mm, ST, 2" sensor

      Montage 2 "-sensor. Materiaal: 316Ti. Gebruik: montagebeugels, FMR10/FMR20.

    • Order code 919792-0000

      Wall bracket for sensor support, ST

      Material: steel zinc coated. Usage: FMR10, FMR20.

    • Order code 919792-0001

      Wall bracket for sensor support, SS

      Material: 316Ti. Usage: FMR10, FMR20.