Guided radar measurement
Time-of-Flight
Levelflex FMP50

Levelflex FMP50 ©Endress+Hauser

Time-of-Flight measuring principle

Commissioning movie for Levelflex FMP5x guided radar and Micropilot FMR5x free space radar

Unique HistoROM data management concept for safe level measurement

Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

Multi-Echo Tracking with Tank Trace marks and traces all echoes signals, not only the level signal - guaranteeing safe measurement at any time

Levelflex FMP50 ©Endress+Hauser

For all basic level applications in liquids

Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50 is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

  • Voordelen

    • Reliable measurement even for changing product and process conditions

    • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

    • Highest reliability due to new Multi-Echo Tracking evaluation

    • Hardware and software...

  • Toepassingsgebied

    Version with rod or rope probe.

    • Process connections: Thread or adapter flange

    • Temperature: -20 to +80°C (-4 to +176°F)

    • Pressure: -1 to +6bar (-14.5 to +87psi)

    • Maximum measuring range: Rod 4m (13ft), rope 12m (39ft)

    • Accuracy: ±2mm (0.08")

    • International...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Guided radar

  • Characteristic / Application

    Basic device

    Rod probe, Rope probe

    Integrated data memory, Factory precalibrated, Reliable measuring for changing medias.

  • Specialities

    Heartbeat Technology,

    Bluetooth® commissioning,

    Operation and maintenance SmartBlue App,

    HistoROM,

    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)

    4-wire (HART)

    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe: +/- 2 mm (0.08 in)

    Rope probe: +/- 2 mm (0.08 in)

  • Ambient temperature

    -40...+80 °C

    (-40...+176 °F)

  • Process temperature

    -20...+80 °C

    (-4...+176 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...6 bar,

    (Vacuum...87 psi)

  • Main wetted parts

    Rod probe: 316L, PPS, Viton

    Rope probe: 316, PPS, Viton

  • Process connection

    Thread:

    G 3/4, MNPT 3/4

    Flange:

    UNI Flange

  • Sensor length

    Rod probe: 4 m (13 ft)

    Rope probe: 12 m (40 ft)

  • Max. measurement distance

    Rod: 4 m (13 ft) Min DK>1.6

    Rope: 12 m (40 ft) Min DK>1.6

  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

  • Options

    Sensor remote with 3 m/ 9 ft cable,

    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Horizontal storage tank cyl.:

    use coax probe

    Corrosive liquids:
    FMP52

    High pressure/ temperatures >80°C/176°F; 6bar/87psi:
    FMP51, FMP54

    Interface measurement

    FMP51, FMP55

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 19
    • Nr 19 Order code 71115175

      Housing filter Brass/Ni GT19/20, 1 set

      Bestaat uit: 2x filterplug messing nikkel. Drukcompensatie filter. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 17
  • 20
    • Nr 20 Order code 71110292

      Deksel GT19 PBT, kijkglas, EPDM

      Materiaal: kunststof PBT-FR kijkglas PC. O-ring EPDM, PTFE gecoat. Gebruik: FHX50, FMP50/FMP51/FMP52/FMP53 /FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57,FMR60/ FMR62/FMR67.

    • Nr 20 Order code 71110293

      Cover GT19 PBT, EPDM

      Materiaal: kunststof PBT, gemetalliseerd. O-ring EPDM, PTFE gecoat. Gebruik: FMP50/FMP51/FMP52/FMP53/FMP54/ FMP55/FMP56/FMP57,FMR50/FMR51/FMR52/ FMR53/FMR54/FMR56/FMR57,FMR60/FMR62/ FMR67.

  • 25
    • Nr 25 Order code 71110295

      Cover GT19 PBT, Terminal Ex, EPDM

      Materiaal: kunststof PBT, gemetalliseerd. Gebruik: terminal compartiment, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67.

  • 20
    • Nr 20 Order code 71110297

      Deksel GT20 Aluminium, met glasvenster,

      Materiaal: aluminium, gecoat O-ring EPDM, PTFE gecoat. Gebruik: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 20 Order code 71110299

      Cover GT20 Alu, HNBR

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE gecoat. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/ 51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71185517

      Cover GT20 Alu, Terminal, OVP, gasket

      Materiaal: aluminium. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, voor overspanningsbeveiliging, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71185518

      Cover GT19 PBT, Terminal, OVP, EPDM

      Materiaal: kunststof PBT, gemetalliseerd. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, voor overspanningsbeveiliging, niet voor Ex d/XP. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67.

    • Nr 25 Order code 71110301

      Cover GT20 Alu, Terminal Ex, gasket

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71110302

      Cover GT20 Alu, Terminal Ex d, gasket

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE-gecoate. FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 65
    • Nr 65 Order code 71110303

      Sealing set housing GT18,GT19,GT20

      Bestaat uit: O-ring 88.5x3.53 EPDM/PTFE, bedekken elektronica compartiment, behuizing GT19. O-Ring 88.5x3.53 NBR, bedekken elektronica compartiment, huisvesting GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, bedekken aansluitruimte, behuizing GT19. O-Ring 91.67x3.53 NBR, bedekken aansluitruimte, huisvesting GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, behuizing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 34
    • Nr 34 Order code 71108591

      I/O mod. Level, 2-dr. 4-20mA,HART,Ex, LP

      Niet voor Ex d/XP. LP=low powered. 1x stroom output HART. Gebruik: FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108591

      I/O mod. Level, 2-dr. 4-20mA,HART,Ex, LP

      Niet voor Ex d/XP. LP=low powered. 1x stroom output HART. Gebruik: FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108591

      I/O mod. Level, 2-dr. 4-20mA,HART,Ex, LP

      Niet voor Ex d/XP. LP=low powered. 1x stroom output HART. Gebruik: FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108591

      I/O mod. Level, 2-dr. 4-20mA,HART,Ex, LP

      Niet voor Ex d/XP. LP=low powered. 1x stroom output HART. Gebruik: FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108594

      I/O module 2-wire, 4-20mA, HART, Ex, V2

      Non-Ex, Ex. 1x stroomuitgang HART. Versie 2. Gebruik: FMP 50/51/52/53/54/55/56/57, FMR 50/51/52/53/54/56/57.

    • Nr 34 Order code 71108594

      I/O module 2-wire, 4-20mA, HART, Ex, V2

      Non-Ex, Ex. 1x stroomuitgang HART. Versie 2. Gebruik: FMP 50/51/52/53/54/55/56/57, FMR 50/51/52/53/54/56/57.

    • Nr 34 Order code 71108594

      I/O module 2-wire, 4-20mA, HART, Ex, V2

      Non-Ex, Ex. 1x stroomuitgang HART. Versie 2. Gebruik: FMP 50/51/52/53/54/55/56/57, FMR 50/51/52/53/54/56/57.

    • Nr 34 Order code 71108594

      I/O module 2-wire, 4-20mA, HART, Ex, V2

      Non-Ex, Ex. 1x stroomuitgang HART. Versie 2. Gebruik: FMP 50/51/52/53/54/55/56/57, FMR 50/51/52/53/54/56/57.

    • Nr 34 Order code 71108595

      I/O module Level, 2-wr.4-20mA,HART,Ex,V1

      Non-Ex, Ex. 1x current output HART. Version 1. Usage: FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108595

      I/O module Level, 2-wr.4-20mA,HART,Ex,V1

      Non-Ex, Ex. 1x current output HART. Version 1. Usage: FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108595

      I/O module Level, 2-wr.4-20mA,HART,Ex,V1

      Non-Ex, Ex. 1x current output HART. Version 1. Usage: FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108599

      I/O module, 2-wire, 4-20mA,HART, PFS, Ex

      Non-Ex, Ex. 1x stroomuitgang HART, 1x PFS. PFS = schakelen output. Gebruik: FMP 50/51/52/53/54/55/56/57, FMR 50/51/52/53/54/56/57.

    • Nr 34 Order code 71108603

      I/O module, 2-draad, PA, PFS, Ex, V1

      Non-Ex, Ex. PROFIBUS PA. PFS=switch output. Version 1. FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108603

      I/O module, 2-draad, PA, PFS, Ex, V1

      Non-Ex, Ex. PROFIBUS PA. PFS=switch output. Version 1. FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71108603

      I/O module, 2-draad, PA, PFS, Ex, V1

      Non-Ex, Ex. PROFIBUS PA. PFS=switch output. Version 1. FMP50/51/52/53/54/55/56/57.

    • Nr 34 Order code 71164940

      I/O module, 2-wire, PA/FF, PFS, Ex, V2

      Niet-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS = schakelen output. Versie 2. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200.

    • Nr 34 Order code 71164940

      I/O module, 2-wire, PA/FF, PFS, Ex, V2

      Niet-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS = schakelen output. Versie 2. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200.

    • Nr 34 Order code 71164940

      I/O module, 2-wire, PA/FF, PFS, Ex, V2

      Niet-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS = schakelen output. Versie 2. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200.

    • Nr 34 Order code 71164940

      I/O module, 2-wire, PA/FF, PFS, Ex, V2

      Niet-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS = schakelen output. Versie 2. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200.

    • Nr 34 Order code 71187812

      I/O mod.Level,2-wr.4-20mA,HART,Ex,LP,V2

      Versie 2. Niet voor Ex d/ XP. LP= lage aangedreven. 1x stroomuitgang HART. Gebruik: FMR50/51/52/53/54/56/57.

    • Nr 34 Order code 71187812

      I/O mod.Level,2-wr.4-20mA,HART,Ex,LP,V2

      Versie 2. Niet voor Ex d/ XP. LP= lage aangedreven. 1x stroomuitgang HART. Gebruik: FMR50/51/52/53/54/56/57.

    • Nr 34 Order code 71187812

      I/O mod.Level,2-wr.4-20mA,HART,Ex,LP,V2

      Versie 2. Niet voor Ex d/ XP. LP= lage aangedreven. 1x stroomuitgang HART. Gebruik: FMR50/51/52/53/54/56/57.

    • Nr 34 Order code 71207473

      I/O mod. Level,4-wr.DC,4-20mA,HART,Ex,V2

      Niet-Ex, Ex. 10,4-48VDC. 1x stroomuitgang HART. Versie 2. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57.

    • Nr 34 Order code 71207474

      I/O mod. Level, 2-wr.2x4-20mA,HART,Ex,V2

      Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Version 2. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57.

    • Nr 34 Order code 71207475

      I/O mod. Level,4-wr.AC,4-20mA,HART,Ex,V2

      Niet-Ex, Ex. 90-253VAC. 1x stroomuitgang HART. Versie 2. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57.

  • 37
    • Nr 37 Order code 71110279

      Terminal set 4-draads, I/O module

      Bestaat uit: 2x terminal 2-pole, groen. 2x terminal 2-pole, rood. Voor: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 37 Order code 71110280

      Klemmenset 2-dr. , I/O Module

      Consists of: 4x Terminal 2 pole, groen. Gebruik: FMP50/51/52/53/54/55/56/57. Gebruik: Promass TB2.

    • Order code 71197334

      Transmitter electronics FHX50

      Bestaat uit: Elektronica, lint kabel. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200, Prosonic Flow 200.

    • Order code

      Remote display FHX50 please order with separate order structure.

    • Order code 71296840

      Plug M12, VA

      To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.

    • Order code 71128617

      Overvoltage protection (OVP10),1-Channel

      4-20mA HART. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128619

      Overvoltage protection (OVP20),2-Channel

      4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71206552

      Cable FHX50, 5m

      Aansluitkabel, afgeschermd. Gebruik: FHX50.

    • Order code 71206554

      Cable FHX50, 10m

      Aansluitkabel, afgeschermd. Gebruik: FHX50.

    • Order code 71206555

      Cable FHX50, 20m

      Aansluitkabel, afgeschermd. Gebruik: FHX50.

    • Order code 71206556

      Cable FHX50, 30m

      Aansluitkabel, afgeschermd. Gebruik: FHX50.

  • 30
  • 40
    • Nr 40 Order code XPD0024-

      Display module, SD02, push buttons

      Voor huisvesting: GT18, GT19, GT20. gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Promass 200/TB2, Prosonic Flow 200, t-massa 150, Promag 200, Prowirl 200. Bestaat uit: Weergeven SD02, helix-kabel, lint kabel, connector cover.

    • Nr 40 Order code XPD0025-

      Display module, SD03, Touch Control

      Voor huisvesting: GT18, GT19, GT20. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. FHX50. Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Bestaat uit: Verlicht beeldscherm SD03, lintkabel, connector.

  • 56
    • Nr 56 Order code 71114452

      Weight FMP5x, rope 4mm 1/6", 316L

      Materiaal: 316L. Grub schroef M6x12, zeskant schroef. Gebruik: FMP50/FMP51/FMP54/FMP56/FMP57.

  • 57
    • Order code 71185027

      Sealing ring DIN7603-A 27x32, FA, 5pcs.

      Process gasket. Usage: Process connection G3/4.

    • Order code

      Check utelized cable length. Replace a faulty unit with a functioning unit of the same type only.

  • 70
    • Nr 70 Order code 71114823

      HF Coax kabel L=3m/9ft, plug

      FMP50/51/52/54/55/56/57, Sensor remote

    • Nr 70 Order code 71235564

      HF Coaxcable L=6m/18ft, plug

      Up to +100oC. Usage: FMP50/51/52/54/55/56/57, Sensor remote.

    • Nr 70 Order code 71235578

      HF Coaxcable L=9m/27ft, plug

      Up to +100oC. Usage: FMP50/51/52/54/55/56/57, Sensor remote.

    • Order code 71373490

      Rope centering star, PEEK, 48-95mm, 1 pc

      Touw afstandhouder voor 4mm touw. D=48-95 mm/1,88-3,74 inch Diameter aanpasbaar. Tmax 250°C/482°F. Materiaal: PEEK. FDA, EG 1935/2004, EU 10/2011 conform. Gebruik: touw montage FMP50/FMP51/ FMP52/FMP54/FMP55.

    • Order code 71373492

      Rope centering star, PEEK, 48-95mm, 5 pc

      Touw afstandhouder voor 4 mm touw. D=48-95 mm/1,88-3,74 inch Diameter aanpasbaar. Tmax 250°C/482°F. Materiaal: PEEK. FDA, EG 1935/2004, EU 10/2011 conform. Gebruik: touw montage FMP50/FMP51/ FMP52/FMP54/FMP55.

    • Order code 71377355

      Bluetooth module (BT10)

      Module voor draadloos data communicatie. Gebruik: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

  • 55
    • Nr 55 Order code XPF0003-

      Sensor FMP50 zonder proces connectie

      T.b.v. gebruik bestaande procesaansluiting FMP50

    • Order code 71102216

      Montageset Cerabar,Deltapilot,Levelflex

      Materiaal: RVS 304. Geschikt voor: wand/pijp montage (2"), PMC71, PMP71/75, FMB70, PMC51, PMP51/55, FMB50/51/52/53. FMP50/51/52/53/54/55/56/57.

    • Order code 71162242

      Weather prot. cover GT18/GT19/GT20, 316L

      Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code XPRFID-

      Spare RFID TAG

      Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.

    • Order code 52014249

      Isolation tie down of the 4mm rope probe

      Isolatie: PPS. Ringschroef: Roestvrij staal. Gebruik: FMP40, FMP56.