Proline Prosonic Flow
E 100 Ultrasonic flowmeter
Economical Ultrasonic flowmeter with integrated temperature measurement
Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. With its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology ensures compliance at all times.
-
Voordelen
Long-term stability – reliable, robust sensor
Reducing further measuring point – multivariable device
Dependable flow measurement – high turndown (200:1)
Time-saving local operation without additional software and hardware – integrated web server
Extended...
-
Toepassingsgebied
The measuring principle is independent of pressure, density, temperature and conductivity
Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines.
Device properties:
Measuring accuracy up to 0.5% for...
Documenten / handleidingen / software
-
Proline Prosonic Flow E 100
Technical Information
Ultrasonic time-of-flight flowmeter Cost-efficient ultrasonic time-of-flight flowmeter with integrated temperature measurement
Technische informatie (TI) -
Proline Prosonic Flow E 100
HART
Operating Instructions
Ultrasonic time-of-flight flowmeter
Inbedrijfsstellingsvoorschriften (BA) -
Proline Prosonic Flow 100
HART
Description of Device Parameters
Ultrasonic time-of-flight flowmeter
Device Parameter (GP) -
Proline Prosonic Flow E
Brief Operating Instructions
Proline Prosonic Flow E Ultrasonic time-of-flight sensor
Short Instruction (KA)12/17Engels -
Proline 100
HART
Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
Short Instruction (KA)12/17Engels -
Replacing the Electronics Module
Installation Instructions
Prosonic Flow E 100, Prosonic Flow E Heat
Installatievoorschriften (EA) -
Replacing Display module, non Ex, Zone 2, Class 1 Div. 2
Installation Instructions
Promass 100, Promag 100, Prosonic Flow E 100
Installatievoorschriften (EA) -
Small parts
Installation Instructions
Promag/Promass 100, CNGmass, LNGmass, LPGmass, Promag 400 Index C, Promag/Promass 500, Prosonic Flow E 100, Prosonic Flow E Heat
Installatievoorschriften (EA) -
Replacing Spare Parts
Installation Instructions
Promag/Promass 100, CNGmass, LNGmass, LPGmass, Promag 400 Index C, Promag/Promass 300, 500, 500-digital, Prosonic Flow E 100, Proson ic Flow E Heat
Installatievoorschriften (EA) -
Proline Prosonic Flow 100
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Ultrasonic time-of-flight flowmeter
Speciale Documentatie (SD) -
Proline Prosonic Flow E 100
The economical ultrasonic flowmeter with integrated temperature measurement
Innovaties (IN)11/17Engels -
Proline Prosonic Flow E 100
Das wirtschaftliche Ultraschall-Durchflussmessgerät mit integrierter Temperaturmessung
Innovaties (IN)11/17Duits -
Proline Prosonic Flow E 100
Le débitmètre à ultrasons économique avec mesure de température intégrée
Innovaties (IN)11/17fr -
Prosonic Flow E100
Ultraschall Durchflussmessgerät zur Messung von Wasser und wasserähnlichen Flüssigkeiten mit integrierter Temperaturmessung.
Tender tekst03/18Duits -
EDD Single, AMS11_HART_FL_ProsonicFlow100_0x115C_0x01_0x02, 22.11.2018 (Flow, Prosonic Flow 100, 0x
HART, AMS Version: 11.0, 11.1, 11.5
Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_ProsonicFlow100_0x115C_0x01_0x02, 22.11.2018 (Flow, Prosonic Flow 100, 0x
HART, AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0
Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_ProsonicFlow100_0x115C_0x01_0x01, 14.12.2017 (Flow, Prosonic Flow 100, 0x11
HART, Experion Version: R432.1 Field Device Manager Version: R450.1
Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicFlow100_9E1B_CDI_FW_1_00_zz_Dev_Rev_01, 14.12.2017 (Flow, Prosonic Flow 100, 0x
HART, DeviceCare Version: 1.04.00 FieldCare Version: 2.12.00
Device Type Manager (DTM)1.10.0.172Language neutral -
DTM Single, ProsonicFlow100_9E1B_HART_FW_1_00_zz_Dev_Rev_01, 14.12.2017 (Flow, Prosonic Flow 100, 0
HART, ArchestrA IDE Version: 4.0.04001 DeviceCare Version: 1.04.00 Field Device Manager Version: R450.1 FieldCare Version: 2.12.00 PACTware Version: 5.0 SP4 Plant Resource Manager Version: R3.31
Device Type Manager (DTM)1.10.0.151Language neutral -
Faceplate Single, PRM_HART_FL_ProsonicFlow100_0x115C_0x01_0x01, 14.12.2017 (Flow, Prosonic Flow 100
HART, Plant Resource Manager Version: R3.31
Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 11.01.2019 (Flow)
HART, DeviceCare Version: 1.05.00 FieldCare Version: 2.13.00
Verification DTM1.06.02Language neutral -
PROSONIC FLOW E
Productcode: 9E1B-, 9EHB- verklaring Number: EC_00597_01.17
EU DeclarationDuits , Engels , fr -
PROSONIC FLOW E
Productcode: 9E1B-, 9EHB- verklaring Number: EC_00598_01.17
EU DeclarationDuits , Engels , fr -
PROSONIC FLOW E
Productcode: 9E1B- Regio: International Keuringsinstantie: FieldComm Group
Fieldbus ConformanceEngels -
PROSONIC FLOW E
Productcode: 9E1B-, 9EHB- Regio: Canada, USA Keuringsinstantie: CSA
Ordinary Location Product SafetyEngels
Accessoires / Spare parts
-
-
Nr 30 Order code XPD0041-
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, Promass 100
Gebruik: Promag / Promass 100/300/500, 500 digitaal, Prosonic Flow E 100, Promag 400 (C). (C) = opwekkingsindex C.
-
-
-
Nr 50 Order code XPD0023-
Display module, 4-wire, 100
Gebruik: Promag 100, Promass 100, Prosonic Flow E 100.
-
-
-
Nr 21 Order code 71185789
Kit cover, compact, Alu
Gebruik: Promass 100, Promag 100, Prosonic Flow E 100 / E Heat, CNGmass, LPGmass, LNGmass. Bestaat uit: Deksel aluminium, gecoat. O-ring 113,90 x 3,53 NBR voor dekking.
-
-
-
Nr 20 Order code 71266334
Kit cover, sight glass, compact, Alu
Gebruik: Promass 100, Promag 100. Bestaat uit: Dek af met kijkglas Aluminium, bekleed. O-ring 113,90 x 3,53 NBR voor dekking.
-
-
-
Nr 70 Order code 71185795
Kit housing gaskets, compact, Alu
Gebruik: Promass 100, Prosonic Flow E 100 / E Heat, CNGmass, LPGmass, LNGmass. Bestaat uit: O-ring 113,90 x 3,53 NBR voor dekking. Pakking EPDM voor behuizing/sensor.
-
-
-
Nr 15 Order code 50098036
PNG Wartel M20 x 1,5 ( 10 stuks ) Exd
-
Nr 15 Order code 50098041
PNG Wartel verloop M20 x 1,5/G 1/2" (10
-
Nr 15 Order code 50098042
PNG Wartel verloop M20 x 1,5/NPT 1/2" (1
-
-
-
Nr 12 Order code 71276494
Kit securing clamp, screw
Gebruik: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensorhuis: Promag 400 (C), (C)= opwekkingsindex C, Promag / Promass 500, Promag / Promass 500 digitaal. Bestaat uit: afdekklem, schroef M4x16.
-
-
-
Order code XPRFID-
Spare RFID TAG
Bestaat uit: RFID-tag, het bevestigen draad, krimp mouw.
-