Proline Prosonic Flow
B 200 Ultrasonic flowmeter

Picture of Ultrasonic flowmeter Proline Prosonic Flow B 200 / 9B2B ©Endress+Hauser

Proline Prosonic Flow B 200

The Ultrasonic Flow Measuring Principle

Endress+Hauser solution for simultaneous measurement of flow and methane content in Wastewater treatment plants (3'05")

Endress+Hauser solution for simultaneous measurement of flow and methane content in Biogas plants (3'05")

Endress+Hauser solution for simultaneous measurement of flow and methane content in Landfill gas plants (3'18")

HistoROM data storage concept

The device for accurate, reliable biogas measurement with loop-powered technology

Prosonic Flow B 200 is the specialist for accurate and reliable measurement of wet biogas and digester gas,even under fluctuating process conditions. With its unique integrated real-time methane fraction analysis, Prosonic Flow B 200 enables continuous measurement and monitoring of gas flow as well as gas quality. In addition to efficient process control and energy balancing, Heartbeat Technology ensures compliance and process safety at all times.

  • Voordelen

    • Integrated real-time methane fraction measurement

    • Optimized for low pressure gas – specialized sensor design

    • No additional pressure loss – full bore design

    • Process transparency – diagnostic capability

    • Convenient device wiring – separate connection compartment

    • Safe operation – no need to open the device due to...

  • Toepassingsgebied

    • The measuring principle is unaffected by gas composition

    • Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.

    Device properties:

    • Multivariable device: flow, temperature and methane

    • Medium temperature: 0 to 80...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Ultrasonic flow

  • Product headline

    The device for accurate, reliable biogas measurement with loop‐powered technology.
    Integrated real‐time methane fraction measurement. Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.

  • Sensor features

    Optimized for low pressure gas – specialized sensor design. No additional pressure loss – full bore design. Process transparency – diagnostic capability. Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F).

  • Transmitter features

    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop‐powered technology. Robust dual-compartment housing.

  • Nominal diameter range

    Single‐path version: DN 50 (2"), DN 80 (3")
    Two‐path version: DN 100 to 200 (4 to 8")

  • Wetted materials

    Sensor: 1.4404/1.4435 (316L)
    Transducer: HNBR
    Temperature sensor (option): AFM 34

  • Measured variables

    Volume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature

  • Max. measurement error

    Volume flow (standard):
    ‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
    ‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
    Volume flow (option):
    ‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
    ‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)

  • Measuring range

    Standard: 1 to 30 m/s (3.28 to 98.4 ft/s)
    Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)

  • Max. process pressure

    11 bar a (159 psi a)

  • Medium temperature range

    0 to +80 °C (+32 to +176 °F)

  • Ambient temperature range

    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4404 (316L)

  • Degree of protection

    IP66/67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control

    (operation from outside)

    Configuration via local display and operating tools possible

  • Outputs

    4‐20 mA HART (passive)

    4‐20 mA (passive)

    Pulse/frequency/switch output (passive)

  • Inputs

    Current input 4‐20 mA (passive)

  • Digital communication

    HART

  • Power supply

    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch Output)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED

  • Material certificates

    3.1 material (wetted parts)

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 34
    • Nr 34 Order code 71108602

      I/O module Flow, 2-wr. 2x4-20mA,HART, Ex

      Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Order code 71128617

      Overvoltage protection (OVP10),1-Channel

      4-20mA HART. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128619

      Overvoltage protection (OVP20),2-Channel

      4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71197334

      Transmitter electronics FHX50

      Bestaat uit: Elektronica, lint kabel. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200, Prowirl 200, Promag 200, Prosonic Flow 200.

    • Order code

      Remote display FHX50 please order with separate order structure.

    • Order code 71296840

      Plug M12, VA

      To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.

  • 30
  • 34
  • 37
    • Nr 37 Order code 71110280

      Klemmenset 2-dr. , I/O Module

      Consists of: 4x Terminal 2 pole, groen. Gebruik: FMP50/51/52/53/54/55/56/57. Gebruik: Promass TB2.

  • 34
    • Nr 34 Order code XPD0016-

      I/O module, 2-wire, 4-20mA,HART, PFS, Ex

      Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.

    • Nr 34 Order code XPD0018-

      I/O,2-wire,4-20mA,HART,PFS,4-20mA input

      Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input.

  • 40
    • Nr 40 Order code XPD0024-

      Display module, SD02, push buttons

      Voor huisvesting: GT18, GT19, GT20. gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Promass 200/TB2, Prosonic Flow 200, t-massa 150, Promag 200, Prowirl 200. Bestaat uit: Weergeven SD02, helix-kabel, lint kabel, connector cover.

    • Nr 40 Order code XPD0025-

      Display module, SD03, Touch Control

      Voor huisvesting: GT18, GT19, GT20. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. FHX50. Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Bestaat uit: Verlicht beeldscherm SD03, lintkabel, connector.

  • 20
    • Nr 20 Order code 71110281

      Cover GT18 316L, HNBR

      Materiaal: 316L. O-ring, EPDM, PTFE gecoat. Gebruik: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Gebruik: Promass 200/ TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 20 Order code 71110282

      Cover GT18 316L, sight glass, HNBR

      Materiaal: 316L. O-ring NBR, PTFE gecoat. Gebruik: FMP51/ 52/54/55/56/57, FMR51/ 52/53/54/57, FMR62/67, FHX50. Gebruik: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110291

      Cover GT18 316L, terminal Ex, gasket

      Materiaal: 316L. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, niet voor Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 25 Order code 71110284

      Cover GT18 316L, terminal Ex d, HNBR

      Materiaal: 316L. O-ring EPDM/PTFE gecoat. Gebruik: terminalcompartiment Ex d/XP, FMP51/ 52/54/55/56/57, FMR51/52/53/54/57, FMR62/67. Gebruik: Promass 200/ TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 25 Order code 71185516

      Cover GT18 316L, Terminal, OVP, gasket

      Materiaal: 316L. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, voor overspanningsbeveiliging, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57,FMR62/FMR67. Gebruik: Promass 200, Prosonic Flow 200, Prowirl 200.

  • 20
    • Nr 20 Order code 71110299

      Cover GT20 Alu, HNBR

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE gecoat. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/ 51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 20 Order code 71110297

      Deksel GT20 Aluminium, met glasvenster,

      Materiaal: aluminium, gecoat O-ring EPDM, PTFE gecoat. Gebruik: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110301

      Cover GT20 Alu, Terminal Ex, gasket

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71110302

      Cover GT20 Alu, Terminal Ex d, gasket

      Materiaal: aluminium, gecoat. O-ring EPDM, PTFE-gecoate. FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71185517

      Cover GT20 Alu, Terminal, OVP, gasket

      Materiaal: aluminium. O-ring EPDM, PTFE gecoat. Gebruik: terminal compartiment, voor overspanningsbeveiliging, niet voor Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57,FMR60/FMR62/FMR67. Gebruik: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 15
  • 65
    • Nr 65 Order code 71110303

      Sealing set housing GT18,GT19,GT20

      Bestaat uit: O-ring 88.5x3.53 EPDM/PTFE, bedekken elektronica compartiment, behuizing GT19. O-Ring 88.5x3.53 NBR, bedekken elektronica compartiment, huisvesting GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, bedekken aansluitruimte, behuizing GT19. O-Ring 91.67x3.53 NBR, bedekken aansluitruimte, huisvesting GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, behuizing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 19
    • Nr 19 Order code 71115174

      Housing filter 316L, GT18, 1 set

      Consists of: filter plug metall 316L. Pressure compensation filter. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 19 Order code 71115175

      Housing filter Brass/Ni GT19/20, 1 set

      Bestaat uit: 2x filterplug messing nikkel. Drukcompensatie filter. Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 17
    • Order code 71162242

      Weather prot. cover GT18/GT19/GT20, 316L

      Gebruik: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67. Gebruik: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 9B2BXX-

      Transmitter Prosonic Flow B 200, 9B2BXX

  • 53
  • 51
    • Nr 51 Order code XPD0004-

      US Transducer, tools, Prosonic Flow B

      Ultrasoon transducer Sensor seal Hot swap tool

Downloads