Proline Promag W 500
Electromagnetic flowmeter

Electromagnetic flowmeter - Proline Promag W 500 ©Endress+Hauser

The Electromagnetic Flow Measuring Principle

Heartbeat Technology simply explained (3'14")

The remote version with up to 3 I/Os and a sensor with EN ISO 12944 corrosion protection

Promag W 500 is the specialist for hazardous areas in the water and wastewater industry and the ideal solution for direct underground installation or permanent underwater use. The innovative remote transmitter maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.

  • Voordelen

    • For direct underground installation or permanent underwater use – certified sensor

    • Secure, reliable long-term operation – robust and completely welded sensor

    • Energy-saving flow measurement – no pressure loss due to cross-section constriction

    • ...

  • Toepassingsgebied

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity

    • The specialist in the water and wastewater industry for the most demanding applications

    Device properties

    • International drinking water...

Kenmerken en specificaties

Terug

Details

  • Meetprincipe

    Electromagnetic

  • Product headline

    The remote version with up to 3 I/Os and a sensor with EN ISO 12944 corrosion protection. For direct underground installation or permanent underwater use. The specialist in the water and wastewater industry for the most demanding applications.

  • Sensor features

    Secure, reliable long-term operation – robust and completely welded sensor. Energy-saving flow measurement – no pressure loss due to cross-section constriction. Maintenance-free – no moving parts. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure).

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 25 to 2000 (1 to 78")

  • Wetted materials

    Liner: Polyurethane; Hard rubber
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

  • Measured variables

    Volume flow, conductivity, mass flow

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

  • Measuring range

    9 dm³/min to 110 000 m³/h (2.5 gal/min to 700 Mgal/d)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)

  • Ambient temperature range

    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    DN 25 to 300 (1 to 12"): AlSi10Mg, coated
    DN 25 to 2000 (1 to 78"): Carbon steel with protective varnish
    Sensor connection housing (standard): AlSi10Mg, coated
    Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L

  • Transmitter housing material

    AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3

  • Display/Operation

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    3 outputs:
    4-20 mA HART (active/passive)
    4-20 mA WirelessHART
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Double pulse output (active/passive)
    Relay output

  • Inputs

    Status input
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV-attestation)

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    ACS, KTW/W270, NSF 61, WRAS BS 6920

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
  • 31
    • Nr 31 Order code 71323007

      Kit power supply, 100-230VAC, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing, elektronisch compartiment.

    • Nr 31 Order code 71323008

      Kit power supply, 24VDC, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing, elektronisch compartiment.

  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, Promass 100

      Gebruik: Promag / Promass 100/300/500, 500 digitaal, Prosonic Flow E 100, Promag 400 (C). (C) = opwekkingsindex C.

  • 33
  • 37
    • Nr 37 Order code 71323010

      Kit module cartridge, 300/500, Ex

      Gebruik: Transmitterbehuizing, elektronisch compartiment. Bestaat uit: module cartridge incl. interconnectie board.

  • 34
  • 46
  • 35
  • 45
    • Nr 45 Order code 71323075

      Kit conn.terminal option A, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie A= HART, Profibus PA, FOUNDATION Fieldbus. Bestaat uit: 2x aansluiting 2-Pol., 1x aansluiting 4-Pol.

  • 50
  • 45
    • Nr 45 Order code 71323076

      Kit conn.terminal option B, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: 2 x aansluiting 2-Pol.

    • Nr 45 Order code 71327819

      Kit conn.terminal option C, 300/500, Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie C= PROFIBUS-DP, Modbus RS485. Bestaat uit: 2x aansluiting 2-Pol., 1x aansluiting 4-Pol.

  • 44
    • Nr 44 Order code 71323264

      Kit connection board, Promag P/W, 500,Ex

      Gebruik: Sensoraansluiting behuizing. Bestaat uit: aansluiting board, dekking van connectie board.

  • 20
    • Nr 20 Order code 71323016

      Kit cover, sight glass, Alu,Non-haz/Exde

      Gebruik: Promag/Promass 300, transmitterbehuizing Alu, Niet gevaarlijk. Promag/Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-Ring 110.7x3.53 HNBR.

    • Nr 20 Order code 71323017

      Kit cover,glass, Alu, -50oC,Non-haz/Exde

      Gebruik: Promass 300, transmitterbehuizing Alu, niet- gevaarlijk. Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

    • Nr 20 Order code 71323020

      Kit cover, sight glass, Alu, Exd

      Gebruik: Promag /Promass 300/500, Transmitter behuizing Alu, Ex. Bestaat uit: Cover Alu, zichtglas, O-Ring 110,7x3,53 HNBR.

    • Nr 20 Order code 71323021

      Kit cover, sight glass, Alu, -50oC, Exd

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, kijkglas, O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

  • 70
    • Nr 70 Order code 71323026

      Kit cover gasket, sight glass/blind

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu/cast. Bestaat uit: 10x O-Ring 110.7x3.53 HNBR.

    • Nr 70 Order code 71323027

      Kit cover gasket,sight glass/blind,-50oC

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu/cast, Bestaat uit: O-ring 110,7 x 3,53 FVMQ, -50°C/-58°F.

  • 22
    • Nr 22 Order code 71323032

      Kit cover, electronic compart., Alu, Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, O-ring 120,2 x 3,53 HNBR.

    • Nr 22 Order code 71323033

      Kit cover, electr.compart., Alu,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu, Ex. Bestaat uit: afdekking Alu, O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

  • 74
    • Nr 74 Order code 71323036

      Kit cover gasket, electronic compart.,Ex

      Gebruik: Promag/Promass 300/500, transmitterbehuizing Alu/cast, Ex. Bestaat uit: 10x O-ring 120,2 x 3,53 HNBR.

    • Nr 74 Order code 71323037

      Kit cover gasket,elect.compart.,-50oC,Ex

      Gebruik: Promag 500, Promass 300/500, transmitterbehuizing Alu/cast, Ex. Bestaat uit: O-ring 120,2 x 3,53 FVMQ, -50°C/-58°F.

  • 23
    • Nr 23 Order code 71323038

      Kit cover, wall mount, Alu, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu, Ex, aansluitruimte. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 HNBR.

    • Nr 23 Order code 71323039

      Kit cover, wall mount, Alu, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount zender Alu, Ex, aansluitruimte. Bestaat uit: afdekking Alu, O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

  • 75
    • Nr 75 Order code 71323042

      Kit cover gasket, wall mount, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, aansluitruimte. Bestaat uit: 10x O-ring 88,50 x 3,53 HNBR.

    • Nr 75 Order code 71323043

      Kit cover gasket, wall mount, -50oC, Ex

      Gebruik: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, aansluitruimte. Bestaat uit: O-ring 88,50 x 3,53 FVMQ, -50°C/-58°F.

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Gebruik: Promag 400(C)= generatie index C, Promag 500, Promass/Promass 500 digitale, sensoraansluiting behuizing. Bestaat uit: afdekking Alu, O-Ring 113,90x3,53 HNBR.

  • 73
    • Nr 73 Order code 71228798

      Kit housing gaskets, remote, Alu

      Gebruik: Promag 400(C)= generatie index C, Promag 500, Promag 500 digitaal, sensoraansluiting behuizing. Bestaat uit: O-Ring 113,90x3,53 HNBR voor dekking, pakking EPDM voor behuizing/sensor L/P/W, O-Ring 29,87x1,78 HNBR voor sensor stekker.

  • 24
    • Nr 24 Order code 71188176

      Kit Cover gasket, sensor L/W, IP68

      Gebruik: Promag 400/800, Promag 500, sensoraansluiting behuizing. Bestaat uit: deksel geplastificeerd, O-ring 91,67 x 3,53 FKM.

  • 73
    • Nr 73 Order code 71188179

      Kit 10 cover gasket, sensor L/W, IP68

      Gebruik: Promag 400/800, Promag 500, sensoraansluiting behuizing. Bestaat uit: 10x O-ring 91,67x3,53 FKM.

  • 71
    • Nr 71 Order code 71323069

      Kit interface gaskets, Promag 300/500

      Gebruik: transmitter behuizing/sensor of transmitter behuizing/muurbevestiging. Bestaat uit: 5x O-ring 88,50 x 3,53 HNBR voor interface, 5x O-Ring 29,87x1,78 HNBR voor voor sensor stekker.

    • Nr 71 Order code 71323070

      Kit interface gaskets, Promag 500, -50oC

      Gebruik: transmitter behuizing/muurbevestiging. Bestaat uit: O-Ring 88,50x3,53 FVMQ voor -interface, -50°C / -58°F, O-Ring 29,87x1,78 FVMQ voor voor sensorstekker, -50°C/-58°F.

  • 11
    • Nr 11 Order code 71323081

      Kit protective cover option A,300/500,Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie A= HART, Profibus PA, Profibus DP, Modbus RS485, FOUNDATION Fieldbus. Bestaat uit: Aansluitruimte beschermhoes, vertoning vervoerder, 2x schroef M4x10.

    • Nr 11 Order code 71323082

      Kit protective cover option B,300/500,Ex

      Gebruik: transmitterbehuizing Alu/cast, aansluitruimte. Optie B= Ethernet, PROFINET. Bestaat uit: Aansluitruimte beschermhoes, vertoning vervoerder, 2x schroef M4x10.

  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Gebruik: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensorhuis: Promag 400 (C), (C)= opwekkingsindex C, Promag / Promass 500, Promag / Promass 500 digitaal. Bestaat uit: afdekklem, schroef M4x16.

  • 87
    • Nr 87 Order code 71343505

      Kit weather protection cover, 300/500

      Gebruik: Promag/Promass 300/500, transmitterbehuizing. Bestaat uit: weer bescherminskap 4404, installatiemateriaal.