  • Meetprincipe

    Guided radar

  • Characteristic / Application

    Coaxial probe:
    not affected by nozzle dimensions or tank installations

    Rod probe:
    for measurement in highly viscous media

    Rope probe:
    large measurement range even with small process connection

  • Interface measurement

    Clean interfaces liquid / liquid

    Simultaneous measurment of interface and overall level

  • Supply / Communication

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)

  • Accuracy

    Coaxial probe: +/-3 mm (0.13")
    Rod probe: +/-3 mm (0.13")
    Rope probe: +/-3 mm (0.13"), >10m:0.03%

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 150 °C
    (-40 °F ... 302 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum ... 40 bar
    (Vacuum ... 580 psi)

  • Main wetted parts

    PTFE
    Coaxial probe: 316L, Alloy C22
    Rod probe: 316L, Alloy C22
    Rope probe: 316

  • Process connection

    G + NPT 3/4" and 1 1/2", DN40 ... DN150

  • Sensor length

    Rod: 4m (178")
    Coax: 4m (178")
    Rope: 35m (1378")

  • Application

  • Max. measurement distance

    Coaxial probe:
    4 m (178") Min. DK > 1.4
    Rod probe:
    4 m (178") Min. DK > 1.6
    Rope probe:
    35 m (1378") Min. DK > 1.6

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    TIIS
    WHG/ Overfill prevention
    SIL
    NACE
    GL Marine
    EN10204-3.1
    IECEx

  • Successor

    FMP50,FMP51

  • Application limits

    Horizontal storage tank cyl.:

    use coax probe

    Aggressive media:

    FMP41C

    Interface measurement:
    Use coax system in favor (coax probe,
    bypass, stilling well)

  • Meetprincipe

    Guided radar

  • Characteristic / Application

    Powdered or granular solids
    Suitable for measurement with heavy dust production

  • Supply / Communication

    2-wire 16-36V, DC
    4-wire 10,5-32V, DC
    4-wire 90-250V, 50/60Hz

  • Ambient temperature

    -40 °C ... +80 °C
    (-40°F ... 176 °F)

  • Process temperature

    -40 °C ... +150 °C
    (-40°F ... 302°F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...40bar
    (Vaccum...580psi)

  • Main wetted parts

    316, PTFE

  • Process connection

    3/4" + 1-1/2" G+NPT
    Flange >=DN40

  • Blocking distance

    Top: 200mm (7.87")
    Bottom: 250mm (9.87") (Rope probe)

  • Sensor length

    Rod probe: 4m (13ft)
    Rope probe: 35m (115ft)

  • Max. measurement distance

    35m (115ft)

  • Communication

    4 ... 20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    TIIS
    WGH
    SIL
    NACE
    EN10204-3.1

  • Options

    Separate electronics, separate display

  • Successor

    FMP56, FMP57

  • Successor

    FMP56, FMP57

  • Application limits

    Dk <= 1,6

Documenten / handleidingen / software

Accessoires / Spare parts

Nr
Order code
Specification
    • Order code 71003045

      EMC C module, gland M20, NEPSI

      Levelflex M, Micropilot M.

    • Order code 71023101

      EMC C module, gland M20, FM

      Levelflex M, Micropilot M.

    • Order code 71023103

      EMC C module, thread NPT1/2, FM

      Levelflex M, Micropilot M.

    • Order code 52006628

      Instrument plug M20-M12 "PA" (WDM)150

      Aansluiting: M20 wartel Verbinding: M12 connector met leads 0,75 mm2, lengte 150 mm Pin aansluiting A: PA- S: Screen B: PA+ n.c.: Niet aangesloten

  • 12
    • Nr 12 Order code 535720-9020

      Set of screws housing F12/T12/F23

      Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

    • Order code 543199-0001

      Protective cover for housing T12/F12, SS

      Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.

  • 20
    • Nr 20 Order code 517391-0011

      Cover F12/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 20 Order code 52005936

      FMR23x/24x deksel m.glas T12

      Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.

    • Nr 20 Order code 52018670

      Deksel F23 316L, glas, pakking

      Materiaal: 316L. Gebruik: VU331, Levelflex M, Micropilot M.

    • Nr 20 Order code 52018671

      Cover F23 316L, gasket

      Material: 316L. Usage: Levelflex M, Micropilot M.

  • 25
    • Nr 25 Order code 518710-0020

      Cover T3/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.

  • 11
    • Nr 11 Order code 52006026

      FMX-M DEKSEL F12, AANSLUITRUIMTE

      Overkapping voor uiteinde Micropilot M, Prosonic M, Levelflex M

    • Nr 11 Order code 52019062

      Cover terminal compartment F12/F23,FHX40

      Hood terminal compartment. Usage: separate display, Micropilot M, Prosonic M, Levelflex M.

  • 35
    • Nr 35 Order code 52006197

      FMR23x/24x aansluitmodule T12

      Cable connection. Usage: housing F12/F23, Micropilot M, Levelflex M, Prosonic M.

    • Nr 35 Order code 52012156

      FMP-M F12 aansluitmodule PA en FF

      PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.

    • Nr 35 Order code 52014817

      Terminal module 4p, HART, ferrit, (F12)

      GL/ABS marine certificaat. Voor: Micropilot M, Levelflex M.

    • Nr 35 Order code 52014818

      Terminal module 4p, PA/FF, ferrit, (F12)

      GL/ABS marine certificate. Usage: Micropilot M, Levelflex M.

    • Nr 35 Order code 52013302

      FMP40 T12 aansluitmodule HART

      Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.

    • Nr 35 Order code 52013303

      FMP40 T12 aansluitmodule PA/FF

      2-wire, PROFIBUS PA/FOUNDATION Fieldbus. Ex d limiter. Usage: housing T12, Levelflex M, Micropilot M, Prosonic M.

    • Nr 35 Order code 52018949

      FMR250 aansluitmod. T12 Hart EExia

      4-pole, 2-draads voor Aluminium T12 behuizing OVP = overvoltage bescherming Levelflex M, Prosonic M, Micropilot M

    • Nr 35 Order code 52018950

      FMR250 aansluitmod. T12 PA/FF EExia,

      2-pole, 2-draads PROFIBUS PA, FOUNDATION Fieldbus voor Aluminium T12 behuizing OVP = overvoltage bescherming Levelflex M, Prosonic M, Micropilot M

  • 11
    • Nr 11 Order code 52005643

      FMX-M afdekplaat T12 behuizing

      Cable compartment, electronics side. Usage: Micropilot M/S, Prosonic M, Levelflex M.

  • 35
    • Nr 35 Order code 52013304

      FMP40 voeding voor 4 dr. 10,5..32 V DC

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Order code 52013305

      FMP40 voeding voor 4 dr 90..250 V AC

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Order code 52015585

      Power supply CSA, 10.5-32VDC (housg F12)

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Order code 52015586

      Power supply CSA, 90-250VAC (housg F12)

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

  • 40
    • Nr 40 Order code 52026443

      FMX-M BEDIENINGSMODULE VU331

      4-Lijns alfanumerische weergave. Gebruik: FMR530/532/533, FMR540, FMU40/41/42/43/44.

    • Order code FHX40-

      Display FHX40

      Remote display + lokale bediening. 4-regelig LC-display. :: Menu-bediening van platte tekst. :: Eenvoudige installatie. :: Gebruikerstaal selecteerbaar. :: Weergave envelopcurve ter plaatse. Gebruik:FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.

    • Order code 52014047

      Dichtingsring DIN7603-A 48x55 FA, 5 st.

      Process gasket. Usage: process connections G1-1/2.

    • Order code 71185027

      Sealing ring DIN7603-A 27x32, FA, 5pcs.

      Process gasket. Usage: Process connection G3/4.

    • Order code 52018204

      FHX40 ADAPTERSET F12 HUIS 2 DRAADS INSTR

      Voor modificatie naar separate display met F12 behuizing and 2-draads elektonica

    • Order code 52018205

      FHX40 ADAPTERSET F12 HUIS 4 DRAADS INSTR

      Modification to remote display. Housing F12, 4-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Levelflex M, Prosonic M.

    • Order code 52016334

      Kabel FHX40, 20m

      Connection cable, doubled shielded. Usage: FHX40.

  • 59
    • Nr 59 Order code 71023427

      Nordlock washer DIN25201-A4, M10, 5 st.

      6mm kabel/16mm kabel, 4mm kabel flens versies, draad G1-1/2, NPT1-1/2. Gebruik: FMP40/45, FMP57.

    • Order code 52013874

      Montagesteun voor buis 2"

      voor aanduider FHX40

    • Order code 52014249

      Isolation tie down of the 4mm rope probe

      Isolatie: PPS. Ringschroef: Roestvrij staal. Gebruik: FMP40, FMP56.

    • Order code 52014250

      Isolation tie down of the 6mm rope probe

      Isolator: PEEK. Ring bout: roestvrij staal. Gebruik: FMP40, FMP57.

    • Order code 52016334

      Kabel FHX40, 20m

      Connection cable, doubled shielded. Usage: FHX40.

    • Order code 71020502

      Kabel FHX40, 5m

      Verbindingskabel, dubbel afgeschermd. Gebruik: FHX40.

    • Order code 71020503

      Kabel FHX40, 10m

      dubbel geïsoleerde connectie kabel voor FHX40 display

    • Order code 71020504

      Kabel FHX40, 30m

      Verbindingskabel, dubbel afgeschermd. Gebruik: FHX40.

    • Order code 71067434

      Modificatietypeplaat, non Ex

      Blanco. Te voorzien van een nieuwe typecodering wanneer een non Ex instrument gemodificeerd is.

    • Order code 71156686

      Threaded pin M10x1, AlloyC22

      Gebruik: deelbare staaf FMP40/45,FMP51/54.

    • Order code 52028063

      HF-test cable 6GHz + resistor

      Coaxkabel. Beëindiging weerstand / verbindingsstuk. Gebruik: FMR530/FMR532/FMR533,FMR540. Dummy antenne.

    • Order code 71000221

      Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60

      Verbinding RS232(52013675)/ ToF adapter FXA291 (71007843). Gebruik: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.

    • Order code 71006590

      HF-testkabel 6GHz

      Coax kabel. Gebruik: FMR230/FMR231, FMR530/FMR531/FMR532/FMR533, FMR540. Dummy antenne.

    • Order code 71007843

      ToF Adapter FXA291

      Gebruik: aansluiting Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, Commubox FXA291.

    • Order code 71069064

      Centreerring PEEK 48-95mm/1.89-3.74in

      Diameter adaptable. Statically dissipative. Tmax 200oC/392oF. Usage: FMP40/FMP45/FMP51/54.

    • Order code 71069065

      Centreerschijf PFA 37mm/16mm

      Tmax 200°C/392°F. Gebruik: FMP40/FMP41C/FMP45, FMP51/FMP52/FMP54.

    • Order code

      Phase out spares

    • Order code
  • Voorganger

  • Opvolger